Search results for "Cyclotron"

showing 10 items of 320 documents

Production and Radiochemical Separation of the Auger Electron Emitter140Nd

2000

Among the Auger electron emitters, the radiolanthanide 140Nd has some unique nuclear properties with potential for endoradiotherapeutic applications. In the present study, 140Nd was produced via the 140Ce(3He,3n) nuclear process at the FZ Julich CV28 cyclotron, irradiating CeO2 with 3He particles of 36 MeV primary energy. Yields of about 5 MBq 140Nd per microAh were experimentally obtained. Batch yields of > 100 MBq 140Nd were reached. 140Nd was separated in 75 +/- 5% radiochemical yield using a two-step process, first by extracting the bulk of the target material according to a Ce(IV)/Nd(III) separation, then by final ion exchange purification.

LanthanideCyclotronElectronsElectronlaw.inventionPhysical PhenomenalawPhysical phenomenaMedicineRadiology Nuclear Medicine and imagingNeodymiumRadioisotopesAuger electron spectroscopyRadiochemistryIon exchangebusiness.industryPhysicsRadiochemistryAuger electron emitterHematologyGeneral MedicineOncologyYield (chemistry)RadiopharmaceuticalsNuclear medicinebusinessActa Oncologica
researchProduct

The Inchworm as a precision translator in a high magnetic field and UHV environment

1989

Abstract A new set-up has been designed and tested for on-line, high-precision mass measurements of short-lived radioactive isotopes via a determination of the ion cyclotron resonance. Ions delivered by the on-line isotope separator ISOLDE at CERN/Geneva are stored in a Penning trap installed in a superconducting solenoid. Due to severe space limitations in the bore of the solenoid, it is impossible to use conventional mechanical feedthroughs for the necessary manipulations inside the uhv chamber. Instead, a number of Inchworms, a high-precision positioning device based on the piezo-electric effect are employed. This publication reports on the first application of this device in a uhv envir…

Large Hadron ColliderPhysics::Instrumentation and Detectorsbusiness.industryChemistryInstrumentationSeparator (oil production)SolenoidCondensed Matter PhysicsPenning trapSurfaces Coatings and FilmsIonMagnetic fieldNuclear physicsOpticsPhysics::Accelerator PhysicsDetectors and Experimental TechniquesNuclear ExperimentbusinessInstrumentationIon cyclotron resonance
researchProduct

Major results from the first plasma campaign of the Wendelstein 7-X stellarator

2017

After completing the main construction phase of Wendelstein 7-X (W7-X) and successfully commissioning the device, first plasma operation started at the end of 2015. Integral commissioning of plasma start-up and operation using electron cyclotron resonance heating (ECRH) and an extensive set of plasma diagnostics have been completed, allowing initial physics studies during the first operational campaign. Both in helium and hydrogen, plasma breakdown was easily achieved. Gaining experience with plasma vessel conditioning, discharge lengths could be extended gradually. Eventually, discharges lasted up to 6 s, reaching an injected energy of 4 MJ, which is twice the limit originally agreed for t…

Magnetic confinementNuclear and High Energy PhysicsTechnology and EngineeringPlasma heatingCyclotron resonanceCONFINEMENT01 natural sciencesElectron cyclotron resonance010305 fluids & plasmaslaw.inventionPHYSICSNuclear physicsstellaratorcurrent drive; magnetic confinement; plasma heating; stellarator; Nuclear and High Energy Physics; Condensed Matter Physicslaw0103 physical sciencesddc:530010306 general physicstellaratorStellaratorPhysicsmagnetic confinementMagnetic confinement fusionplasma heatingcurrent drive;magnetic confinement;plasma heating;stellaratorPlasma530 PhysikCondensed Matter PhysicsTRANSPORTCurrent drivecurrent driveElectron temperaturePlasma diagnosticsAtomic physicsWendelstein 7-X[PHYS.ASTR]Physics [physics]/Astrophysics [astro-ph]StellaratorNuclear Fusion
researchProduct

Foodomics assessed by Fourier transform mass spectrometry

2019

Abstract With its ultrahigh resolution power and excellent mass accuracy, Fourier transform ion cyclotron resonance mass spectrometry is the perfct tool to analyze the “foodome” as the set of all polar small molecular compounds present in an investigated food sample. We present here selected applications of this technique in unraveling the metabolome in complex foods (thermally affected, fermentation products, distillates) such exemplified with Maillard reaction products or with wines and spirits. Technical considerations for high resolution mass analyzers are provided from a practical point of view. Moreover, aspects of food safety and nutritional quality are covered by presenting applicat…

Maillard reactionsymbols.namesakeChromatographyUltrahigh resolutionFoodomicsChemistryMetabolomesymbolsHigh resolutionFood sampleNutritional qualityFourier transform ion cyclotron resonance
researchProduct

Quantitative Spatial Analysis of the Mouse Brain Lipidome by Pressurized Liquid Extraction Surface Analysis

2014

Here we describe a novel surface sampling technique termed pressurized liquid extraction surface analysis (PLESA), which in combination with a dedicated high-resolution shotgun lipidomics routine enables both quantification and in-depth structural characterization of molecular lipid species extracted directly from tissue sections. PLESA uses a sealed and pressurized sampling probe that enables the use of chloroform-containing extraction solvents for efficient in situ lipid microextraction with a spatial resolution of 400 μm. Quantification of lipid species is achieved by the inclusion of internal lipid standards in the extraction solvent. The analysis of lipid microextracts by nanoelectrosp…

MaleIn situChromatographyChemistryLiquid-Liquid ExtractionExtraction (chemistry)Analytical chemistryBrainShotgun lipidomicsLipidomeMass spectrometryLipidsMass SpectrometryFourier transform ion cyclotron resonanceAnalytical ChemistryMice Inbred C57BLMiceMicroscopy FluorescenceFragmentation (mass spectrometry)Liquid–liquid extractionSpectroscopy Fourier Transform InfraredPressureAnimalsAnalytical Chemistry
researchProduct

Mass Measurements with the CSS2 and CIME cyclotrons at GANIL

2005

Commune avec ACEN; This paper presents two original direct mass-measurement techniques developed at GANIL using the CSS2 and CIME cyclotrons as high-resolution mass spectrometers. The mass measurement with the CSS2 cyclotron is based on a time-of-flight method along the spiral trajectory of the ions inside the cyclotron. The atomic mass excesses of 68Se and 80Y recently measured with this technique are -53.958(246) MeV and -60.971(180) MeV, respectively. The new mass-measurement technique with the CIME cyclotron is based on the sweep of the acceleration radio-frequency of the cyclotron. Tests with stable beams have been performed in order to study the accuracy of this new mass-measurement m…

Mass numberChemistryCyclotron020206 networking & telecommunicationsParticle accelerator02 engineering and technologyrp-process[PHYS.NEXP]Physics [physics]/Nuclear Experiment [nucl-ex]Mass spectrometryAtomic masslaw.inventionIonNuclear physicsAccelerationlaw29.20.Hm 29.30.-h 21.10.Dr 27.50.+e0202 electrical engineering electronic engineering information engineering020201 artificial intelligence & image processing
researchProduct

Precision Measurements of Atomic Masses Using Highly Charged Ions and Atomic Clusters

1992

A high precision Penning trap will be connected to the beam of highly charged ions from the electron beam ion source CRYSIS at the Manne Siegbahn Institute for Physics (MSI) in Stockholm. The first series of experiments aim at accurate mass measurements by exploiting the increase of the cyclotron frequency with the charge state of the trapped ion. Using charged states of about 50 it should be possible to achieve relative mass accuracies for mass doublets better than 10-9. For this high accuracy a Penning trap with low imperfections is needed, as well as a sophisticated beam handling and retardation system for controlled injection of the ions into the trap. In order to minimize the effect of…

Mass numberPhysicslawCyclotronCluster (physics)Atomic physicsPenning trapIon sourceAtomic massBeam (structure)Ionlaw.invention
researchProduct

Precision mass measurements using a penning trap and highly charged ions produced in an electron beam ion source

1997

A method for precision mass measurements in a Penning trap using highly charged ions produced in an electron beam ion source (CRYSIS) has been developed. The cyclotron frequencies for O8+, 7+, 6+, 5+ and Ar18+, 17+, 16+, 15+, 14+, 13+ ions have been determined by the excitation of the sum frequency v+ + v−. In addition to CRYSIS ions, H+, H2+ and He+ ions were produced by electron bombardment of the H2 rest gas or helium gas introduced through an UHV leak valve into an auxiliary ion trap (or a pre-trap). A technique for fast (seconds) interchanging of the ion species in the precision trap has been implemented to reduce the long term magnetic field drift.

Materials scienceCyclotronCondensed Matter PhysicsIon gunPenning trapAtomic and Molecular Physics and OpticsIon sourceIonlaw.inventionPhysics::Plasma PhysicslawCathode rayIon trapAtomic physicsMathematical PhysicsExcitationPhysica Scripta
researchProduct

Status of new developments in the field of high-current gasdynamic ECR ion sources at the IAP RAS

2018

The experimental and theoretical research carried out in the past at the Institute of Applied Physics (IAP RAS) resulted in development of a new type of electron cyclotron resonance ion source (ECRIS) – the gasdynamic ECRIS. The gasdynamic ECRIS features a confinement mechanism in a magnetic trap that is different from Geller’s classical ECRIS confinement i.e. the quasi-gasdynamic one similar to that in fusion mirror traps . Such ion source type has demonstrated good performance producing high current (100-300 mA) multi-charged ion beams with moderate average charge (Z=4-5 for argon) and especially high efficiency for low emittance hydrogen and deuterium beam formation (500 emA current, cur…

Materials scienceField (physics)ionitta114syklotronitionsHigh currentplasmatekniikkacyclotron resonanceEngineering physicsplasmaIon
researchProduct

Study of Gasdynamic Electron Cyclotron Resonance Plasma Vacuum Ultraviolet Emission to Optimize Negative Hydrogen Ion Production Efficiency

2019

Negative hydrogen ion sources are used as injectors into accelerators and drive the neutral beam heating in ITER. Certain processes in low-temperature hydrogen plasmas are accompanied by the emission of vacuum ultraviolet (VUV) emission. Studying the VUV radiation therefore provides volumetric rates of plasma-chemical processes and plasma parameters. In the past we have used gasdynamic ECR discharge for volumetric negative ion production and investigated the dependencies between the extracted H$^-$ current density and various ion source parameters. It was shown that it is possible to reach up to 80 mA/cm$^2$ of negative ion current density with a two electrode extraction. We report experime…

Materials scienceHydrogenPlasma parameterschemistry.chemical_elementFOS: Physical sciencesRadiationplasmafysiikka01 natural sciencesElectron cyclotron resonance010305 fluids & plasmasIonnegative hydrogen ion productionPhysics::Plasma Physics0103 physical sciencesgasdynamic electron cyclotron resonanceInstrumentation010302 applied physicssyklotronitplasma vacuum ultraviolet emissionPlasmaIon sourcePhysics - Plasma PhysicsPlasma Physics (physics.plasm-ph)chemistryPhysics::Accelerator PhysicsAtomic physicsCurrent density
researchProduct