Spectroscopic method to study low charge state ion and cold electron population in ECRIS plasma

2018

The results of optical emission spectroscopy experiments probing the cold electron population of a 14 GHz Electron Cyclotron Resonance Ion Source (ECRIS) are reported. The study has been conducted with a high resolution spectrometer and data acquisition setup developed specifically for the diagnostics of weak emission line characteristic to ECRIS plasmas. The optical emission lines of low charge state ions and neutral atoms of neon have been measured and analyzed with the line-ratio method. The aforementioned electron population temperature of the cold electron population (Te < 100 eV) is determined for Maxwell-Boltzmann and Druyvesteyn energy distributions to demonstrate the applicability …

Materials sciencespektroskopiachemistry.chemical_elementplasmafysiikka01 natural sciencesElectron cyclotron resonanceIonlow charge state ionNeonIonization0103 physical sciencesspectroscopic methodEmission spectrumcold electron populationInstrumentation010302 applied physicsta114010308 nuclear & particles physicssyklotronitPlasmaECRIS plasmaIon sourcechemistryPlasma diagnosticsAtomic physicsReview of Scientific Instruments
researchProduct

The effect of gas mixing and biased disc voltage on the preglow transient of electron cyclotron resonance ion source

2012

The effect of gas mixing and biased disc voltage on the preglow of electron cyclotron resonance ion source plasma has been studied with the AECR-U type 14 GHz ion source. It was found that gas mixing has a significant effect on the preglow. The extracted transient beam currents and efficiency of the heavier species increase, while the currents and efficiency of the lighter species decrease when gas mixing is applied. The effect of the biased disc was found to be pronounced in continuous operation mode in comparison to preglow. The data provide information on the time scales of the plasma processes explaining the effects of gas mixing and biased disc. The results also have implications on pr…

Materials scienceta114Cyclotron resonanceParticle acceleratorPlasmaElectron cyclotron resonanceIon sourcelaw.inventionPhysics::Plasma PhysicslawBeta (plasma physics)Electric potentialAtomic physicsInstrumentationAstrophysics::Galaxy AstrophysicsBeam (structure)Review of Scientific Instruments
researchProduct

An inductively heated hot cavity catcher laser ion source.

2015

An inductively heated hot cavity catcher has been constructed for the production of low-energy ion beams of exotic, neutron-deficient Ag isotopes. A proof-of-principle experiment has been realized by implanting primary (107)Ag(21+) ions from a heavy-ion cyclotron into a graphite catcher. A variable-thickness nickel foil was used to degrade the energy of the primary beam in order to mimic the implantation depth expected from the heavy-ion fusion-evaporation recoils of N = Z (94)Ag. Following implantation, the silver atoms diffused out of the graphite and effused into the catcher cavity and transfer tube, where they were resonantly laser ionized using a three-step excitation and ionization sc…

Materials scienceta114CyclotronLaserIon sourceCharged particlelaw.inventionIonhot cavity catcherlawIonizationionsGraphiteAtomic physicsInstrumentationExcitationThe Review of scientific instruments
researchProduct

Electron cyclotron resonance ion source plasma chamber studies using a network analyzer as a loaded cavity probe

2012

A method and first results utilizing a network analyzer as a loaded cavity probe to study the resonance properties of a plasma filled electron cyclotron resonance ion source (ECRIS) plasma chamber are presented. The loaded cavity measurements have been performed using a dual port technique, in which two separate waveguides were used simultaneously. One port was used to ignite and sustain the plasma with a microwave source operating around 11 GHz and the other was used to probe the cavity properties with the network analyzer using a frequency range around 14 GHz. The first results obtained with the JYFL 14 GHz ECRIS demonstrate that the presence of plasma has significant effects on the reson…

Materials scienceta114business.industryCyclotron resonanceResonancePlasmaNetwork analyzer (electrical)Ion sourceElectron cyclotron resonancePhysics::Plasma PhysicsOptoelectronicsAtomic physicsbusinessInstrumentationMicrowaveIon cyclotron resonanceReview of Scientific Instruments
researchProduct

Investigation into the gas mixing effect in ECRIS plasma using Kα and optical diagnostics

2018

Mixing a lighter gas species into the plasma of an ECRIS is known to enhance high charge state production of the heavier gas species. With this investigation, Kα diagnostics, optical emission spectroscopy and the measured charge state distribution of the extracted beam were combined to shed more light on the physics governing this phenomenon. Kα diagnostics data from two ion sources, the JYFL 14 GHz ECRIS and the GTS at iThemba LABS, are presented to gain confidence on the observed trends. The results seem to favor ion cooling as the most likely mechanism responsible for the favorable influence of the gas mixing.Mixing a lighter gas species into the plasma of an ECRIS is known to enhance hi…

Materials scienceta114ionitsyklotronitPlasmaplasmafysiikkaGas mixingIonNuclear physicsOptical diagnosticsIon coolingionsOptical emission spectroscopycyclotron resonanceState distributionplasmaplasma (kaasut)Beam (structure)AIP Conference Proceedings
researchProduct

Analysis of radionuclide concentration in air released through the stack of a radiopharmaceutical production facility

2014

The quantities of positron emitting radionuclides used in medical diagnostics and the number of radiopharmaceutical production facilities have been estimated to be growing worldwide. In this field, an amount of these radionuclides might become airborne and escape into the environment during the process of production and/or during administration by hospital personnel. Therefore, the analysis of dose to the operating staff as well as to the public, due to releases through the stack, is a very important issue. To this end, sampling and measurement of radionuclide concentration in air released through the stack of a Nuclear Medicine Center (NMC), provided with a cyclotron for radiopharmaceutica…

Medical cyclotron radioactive air effluent PET Potential dose.Settore ING-IND/20 - Misure E Strumentazione Nucleari
researchProduct

Size- and Structure-Selective Noncovalent Recognition of Saccharides by Tetraethyl and Tetraphenyl Resorcinarenes in the Gas Phase

2008

The noncovalent complexation of tetraethyl and tetraphenyl resorcinarenes with mono-, di-, and oligosaccharides was studied with negative-polarization electrospray ionization quadrupole ion trap and electrospray ionization Fourier-transform ion cyclotron resonance mass-spectrometric analysis. The saccharides formed 1:1 complexes with deprotonated resorcinarenes, which exhibited clear size and structure selectivity in their complexation. In the case of the monosaccharides, hexoses formed much more abundant and kinetically stable complexes than pentoses or deoxyhexoses. A comparison of the mono-, di-, and oligosaccharides revealed that both the relative abundance and stability of the complexe…

Models MolecularCellobiosePhenylalanineElectrospray ionizationCarbohydratesCrystallography X-RayMass spectrometryMass SpectrometryCatalysisSubstrate SpecificityDeprotonationPolymer chemistryCarbohydrate ConformationOrganic chemistryQuadrupole ion trapHost–guest chemistrychemistry.chemical_classificationOrganic ChemistryGeneral ChemistryOligosaccharideResorcinareneKineticschemistryGasesCalixarenesIon cyclotron resonanceChemistry - A European Journal
researchProduct

Alkali metal mediated resorcarene capsules: An ESI-FTICRMS study on gas-phase structure and cation binding of tetraethyl resorcarene and its per-meth…

2002

AbstractElectrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (ESI-FTICRMS) with additional ab initio calculations were used to examine the alkali metal cation binding selectivity (i.e., molecular recognition) and host properties of tetraethyl resorcarene (1) and its per-methylated derivative (2). The significance of intramolecular hydrogen bonding for the crown conformation was demonstrated. The presence of intramolecular flip-flop hydrogen bonding in 1 was confirmed both with calculations and in ND3-exchange experiments. All the alkali metal cations formed host–guest complexes by docking inside the cavity of the host. Complexation with the larger cations, esp…

Models MolecularSpectrometry Mass Electrospray IonizationCation bindingFourier AnalysisHydrogen bondChemistryStereochemistryElectrospray ionizationMolecular ConformationHydrogen BondingAlkaliesIon cyclotron resonance spectrometryMethylationFourier transform ion cyclotron resonanceMolecular recognitionMetalsStructural BiologyIntramolecular forcePolymer chemistryMoleculePolycyclic CompoundsSpectroscopyJournal of the American Society for Mass Spectrometry
researchProduct

Mass spectrometric studies on small open-chain piperazine-containing ligands and their transition metal complexes

2001

Electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry was used to characterize the complexes formed between open-chain piperazine-containing ligands and transition metal salts (Cobalt, Copper, Zinc, and Cadmium as chlorides, nitrates, and acetates). Only single-charged complexes were observed, formed of one ligand (L) and mainly one metal ion (M). Since the net charge of the complexes was one, a counterion (X) was attached to some of the complexes, with formation of [L + M + X]+ complexes, and a proton was lost from others, as in [L − H + M]+ complexes. In most cases the composition of the complexes was more dependent on the ligand than the metal salt. Collisio…

Models Molecularchemistry.chemical_classificationSpectrometry Mass Electrospray IonizationFourier AnalysisLigandMetal ions in aqueous solutionInorganic chemistryMolecular ConformationCobaltLigandsPiperazinesFourier transform ion cyclotron resonanceNon-innocent ligandStructure-Activity RelationshipZincchemistry.chemical_compoundCrystallographychemistryTransition metalMetalsCarboxylateCounterionMetal aquo complexCopperSpectroscopyJournal of Mass Spectrometry
researchProduct

Isomeric fission yield ratios for odd-mass Cd and In isotopes using the Phase-Imaging Ion-Cyclotron-Resonance technique

2018

Isomeric yield ratios for the odd-$A$ isotopes of $^{119-127}$Cd and $^{119-127}$In from 25-MeV proton-induced fission on natural uranium have been measured at the JYFLTRAP double Penning trap, by employing the Phase-Imaging Ion-Cyclotron-Resonance technique. With the significantly improved mass resolution of this novel method isomeric states separated by 140 keV from the ground state, and with half-lives of the order of 500 ms, could be resolved. This opens the door for obtaining new information on low-lying isomers, of importance for nuclear structure, fission and astrophysics. In the present work the experimental isomeric yield ratios are used for the estimation of the root-mean-square a…

Nuclear TheoryAnalytical chemistryFOS: Physical sciencesFission product yield01 natural sciences7. Clean energySubatomär fysikydinreaktiotPhysics::Plasma Physics0103 physical sciencesSubatomic PhysicsPhysics::Atomic and Molecular ClustersfissionNuclear Experiment (nucl-ex)010306 general physicsNuclear ExperimentNuclear Experimentnuclear reactionsPhysicsIsotopeta114010308 nuclear & particles physics3. Good healthfissioPhase imagingisomer decaysydinfysiikkaIon cyclotron resonance
researchProduct