Search results for "D-DIMER"
showing 10 items of 34 documents
Evaluation of the Stratus® CS Acute Care™ D-dimer assay (DDMR) using the Stratus® CS STAT Fluorometric Analyzer: A prospective multisite study for ex…
2012
Abstract Background D-dimer testing is an integral part of the diagnostic algorithm in excluding patients with venous thromboembolism. In this study, we prospectively evaluated the Stratus DDMR D-dimer test in patients suspected of pulmonary embolism (PE) and deep vein thrombosis (DVT). Methods Patients suspected of venous thromboembolism were prospectively enrolled at four different clinical sites, with sodium citrate and lithium heparin plasma was tested using the DDMR D-dimer test on the Stratus CS analyzer. Results 1,012 patients were enrolled for analysis, with 85/603 (14.1%) patients with PE and 80/443 (18.1%) with DVT, and four of the patients (0.4%) with PE and DVT. For the samples …
Long- and short-term in vitro D-dimer stability measured with INNOVANCE D-Dimer.
2009
Summary In vitro D-dimer stability in plasma is widely assumed, but has not yet been documented by systematic studies using samples covering a wide range of D-dimer. We investigated the short- and long-term stability of D-dimer in clinical citrated plasma samples with normal and pathological levels. The short-term stability was analysed by measuring D-dimer fresh, after storage of plasma for 4 hours at room temperature (RT) and after an additional 24 h storage at +2 to +8°C (n=40). Long-term stability samples (n=40) were measured fresh and after storage for 19, 25 and 36 months at ≤-60°C. The effect of repeated freezing was analysed by measuring samples (n=50) fresh and after four consecuti…
Pr�vention thromboembolischer Komplikationen in der Unfallchirurgie durch Dosisanpassung von niedermolekularem Heparin anhand TAT- und D-Dimer-Werten
2003
Bei unfallchirurgischen Patienten tritt in bis zu 40% eine tiefe Beinvenenthrombose auf. Das individuelle Risiko kann kaum kalkuliert werden. 518 unfallchirurgische Patienten mit Prophylaxe durch eine tagliche Einzeldosis eines niedermolekularen Heparins (NMH) wurden praoperativ und bis zu 10 Tage postoperativ in einer prospektiven Untersuchung beobachtet. Sie wurden in 2 Gruppen unterteilt: Gruppe I mit Huft- und Oberschenkeloperationen sowie Kniegelenkprothesen und Gruppe II mit Knie- und Unterschenkeloperationen. Bestimmt wurden Thrombin-Antithrombin-Komplex und D-Dimer. Eine 2. Dosis NMH wurde bei Uberschreiten des D-Dimer-Cut-off-Wertes verabreicht. Bei sonographischem Verdacht auf ein…
Incidence, risk factors, and thrombotic load of pulmonary embolism in patients hospitalized for COVID-19 infection
2021
Summary Objective To determine the incidence, characteristics, and risk factors of pulmonary embolism (PE) among patients hospitalized for COVID-19. Patients and Methods We performed a prospective observational study of a randomly selected cohort of consecutive patients hospitalized for COVID-19 infection between March 8, 2020 through April 25, 2020. All eligible patients underwent a computed tomography pulmonary angiography independently of their PE clinical suspicion and were pre-screened for a baseline elevated D-dimer level. Results 119 patients were randomly selected from the 372 admitted to one tertiary hospital in Valencia (Spain) for COVID-19 infection during the period of study. Se…
Early effects of unfractionated heparin on clinical and radiological signs and D-dimer levels in patients with COVID-19 associated pulmonary embolism…
2021
Validation of STA-Liatest D-Di assay for exclusion of pulmonary embolism according to the latest Clinical and Laboratory Standard Institute/Food and …
2017
: Combined clinical pretest probability (PTP) and D-dimer testing have great diagnostic value for pulmonary embolism exclusion. To harmonize performance levels of D-dimer assays available on the market, the Clinical and Laboratory Standard Institute (CLSI) has published a guideline, endorsed by the US Food and Drug Administration (FDA). Such guideline specifies the ideal D-dimer assay characteristic and target population. This study was conducted following the CLSI guideline to upgrade the assay-intended use and obtain FDA clearance of STA-Liatest D-Di assay for pulmonary embolism exclusion in patient with low/moderate PTP. This was an international, multicenter, prospective nonrandomized, …
D-dimer concentrations in acute urticaria in children
2021
Introduction: Urticaria is a clinical entity presenting as wheals, angioedema, or both simul-taneously. Elevated D-dimer levels were reported in the course of chronic spontaneous urticaria. Data regarding D-dimer levels in acute urticaria in children are limited. Objectives: To assess potential associations between duration of glucocorticosteroid (GCS) therapy and D-dimer concentrations in children with acute urticaria. Patients, materials, and methods: Hospital records of 106 children (59 females), aged 5.57 ± 4.91 years, hospitalized in 2014–2018 were analyzed retrospectively. The study group consisted of pediatric patients admitted to the hospital due to severe acute urticaria resistant …
International, multicenter evaluation of a new D-dimer assay for the exclusion of venous thromboembolism using standard and age-adjusted cut-offs.
2017
We sought to determine the test characteristics of an automated INNOVANCE D-dimer assay for the exclusion of pulmonary embolism (PE) and deep venous thrombosis (DVT) in emergency department (ED) patients using standard and age-adjusted cut-offs.Cross-sectional, international, multicenter study of consecutive patients with suspected DVT or PE in 24 centers (18 USA, 6 Europe). Evaluated patients had low or intermediate Wells PE or DVT scores. For the standard cut-off, a D-dimer result500 ng/ml was negative. For the age adjusted cut-off, we used the formula: Age (years) ∗ 10. The diagnostic standard was imaging demonstrating PE or DVT within 3 months. We calculated test characteristics using s…
Serial 2-Point Ultrasonography Plus D-Dimer vs Whole-Leg Color-Coded Doppler Ultrasonography for Diagnosing Suspected Symptomatic Deep Vein Thrombosis
2008
Context Patients with suspected deep vein thrombosis ( DVT) of the lower extremities are usually investigated with ultrasonography either by the proximal veins ( 2-point ultrasonography) or the entire deep vein system ( whole- leg ultrasonography). The latter approach is thought to be better based on its ability to detect isolated calf vein thrombosis; however, it requires skilled operators and is mainly available only during working hours. No randomized comparisons are yet available evaluating the relative values of these 2 strategies. Objective To assess if the 2 diagnostic strategies are equivalent for the management of symptomatic outpatients with suspected DVT of the lower extremities.…
Combined lymphocyte/monocyte count, D-dimer and iron status predict COVID-19 course and outcome in a long-term care facility
2020
Abstract Background The Sars-CoV-2 can cause severe pneumonia with multiorgan disease; thus, the identification of clinical and laboratory predictors of the progression towards severe and fatal forms of this illness is needed. Here, we retrospectively evaluated and integrated laboratory parameters of 45 elderly subjects from a long-term care facility with Sars-CoV-2 outbreak and spread, to identify potential common patterns of systemic response able to better stratify patients’ clinical course and outcome. Methods Baseline white blood cells, granulocytes’, lymphocytes’, and platelets’ counts, hemoglobin, total iron, ferritin, D-dimer, and interleukin-6 concentration were used to generate a …