Search results for "DENTAL IMPLANTS"
showing 10 items of 281 documents
Effect on osseointegration of two implant macro-designs:A histomorphometric analysis of bicortically installed implants in different topographic site…
2018
Background To evaluate the effect of two different implant macro-designs on the sequential osseointegration at bicortically installed implants in the rabbit tibia. A further aim is to compare the osseointegration at different topographic zones. Material and Methods 27 New Zealand rabbits were implemented. Two implants, one for each macro-design (Ticare Inhex® or Ticare Quattro®, Mozo-Grau, Valladolid, Spain), were randomly implanted in the diaphysis or metaphysis of each tibia. The flaps were sutured to allow a submerged healing. The animals were sacrificed after 2, 4 or 8 weeks. Ground sections were prepared and analyzed. Results No statistically significant differences were found between …
Effects of locally applied Insulin-like Growth Factor-I on osseointegration.
2019
Background The aim of this study was to assess the effect of local application of IGF-I on osseointegration of dental implants placed in osteoporotic bones. Material and Methods 16 rabbits were randomly distributed into two groups: eight animals were ovariectomized and fed a low-calcium diet for six weeks, in order to induce experimental osteoporosis, and the others were sham-operated and fed a standard diet. A titanium implant was inserted into the tibiae in both groups. In half of the rabbits, 4 μg of IGF-I was applied into the ostectomy, prior to the implant insertion. A total of 32 implants were placed. Animals were sacrificed two weeks after surgery and decalcified samples were process…
The use of Human Allogenic Graft (HBA) for Maxillary Bone Regeneration: Review of Literature and Case Reports
2012
The use of graft materials is developed from the strong demand to support the complete bone regeneration of the empty socket and to increase the bone volume in treating the atrophies of sites already consolidated and with adverse alveolar bone conditions. A number of graft materials with different origin and mechanism of bone regeneration are available. Autologous graft materials, coming from the same patient, are defined as the gold-standard. The need of a second surgical site and the risk of morbidity and complications may make their use difficult. Human bone allografts (HBA) have been recently introduced, in order to offer an alternative to the autologous grafts. They have demonstrated t…
A biphasic calcium phosphate coating for potential drug delivery affects early osseointegration of titanium implants.
2016
Background Calcium phosphate (CaP) surface coatings may accelerate osseointegration and serve as a drug delivery system for mineral-binding biomolecules. In a pilot study, the impact of a commercially available, thin CaP coating on early osseous bone remodeling was compared with a modern, subtractive-treated rough surface (SLA-like) in an animal trial. Methods In 16 rabbits, 32 endosseous implants (CaP; n = 16, SLA-like; n = 16) were bilaterally inserted in the proximal tibia after randomization. After 2 and 4 weeks, bone-implant contact (BIC;%) in the cortical (cBIC) and the trabecular bone (sBIC) as well as volume of bone within the screw thread with the highest amount of new-formed bone …
Calcium Phosphate-Coated Titanium Implants in the Mandible: Limitations of the in vivo Minipig Model
2020
<b><i>Introduction:</i></b> We aimed to compare implant osseointegration with calcium phosphate (CaP) surfaces and rough subtractive-treated sandblasted/acid etched surfaces (SA) in an in vivo minipig mandible model. <b><i>Materials and Methods:</i></b> A total of 36 cylindrical press-fit implants with two different surfaces (CaP, <i>n</i> = 18; SA, <i>n</i> = 18) were inserted bilaterally into the mandible of 9 adult female minipigs. After 2, 4, and 8 weeks, we analyzed the cortical bone-to-implant contact (cBIC; %) and area coverage of bone-to-implant contact within representative bone chambers (aBIC; %). <b><…
Fracture resistance and the mode of failure produced in metal-free crowns cemented onto zirconia abutments in dental implants.
2019
The purpose of the investigation was to analyze fracture resistance and mode of failure of zirconium oxide (zirconia) abutments placed on dental implants bearing crowns of different esthetic materials: zirconia, lithium disilicate (LDS), and nano-ceramic resin, for replacing single teeth in the anterior sector. Eighty implant-abutment-crown units were divided into four groups: Group T-MC (control): 20 metal-ceramic crowns cemented onto titanium abutments; Group Z-Z: 20 zirconia crowns on zirconia abutments; Group Z-LD: 20 lithium disilicate crowns on zirconia abutments; and Group Z-NCR: 20 nano-ceramic resin crowns on zirconia abutments. Specimens underwent a fatiguing process (dynamic load…
Implant-supported metal-ceramic and resin-modified ceramic crowns: A 5-year prospective clinical study.
2018
Abstract Statement of problem Because of market demand for innovation, new restoration materials have been introduced without adequate testing; clinical failure may be the consequence, and clinical studies are needed. Purpose The purpose of this clinical study was to evaluate the biological and mechanical clinical behavior of implant-supported resin-modified ceramic crowns compared with that of metal-ceramic crowns. Material and methods Forty-two participants aged between 35 and 65 years received single implants in posterior edentulous sites. After the osseointegration period, half of the implants (selected randomly) (n=25) were restored with metal-ceramic crowns (MC group) and the other ha…
Dynamic and static computer-guided surgery using the double-factor technique for completely edentulous patients: A dental technique.
2021
A novel computer-assisted surgery (CAS) technique that merges dynamic and static CAS approaches to treat completely edentulous patients with dental implants is described. Radiographic and surgical stents are designed with specific fiducial markers that are recognized by the static and dynamic CAS software program. During the surgical procedure, implants are placed following the static surgical guide and the indications from the dynamic navigation system. This technique combines the advantages of static and dynamic CAS approaches to allow accurate and predictable minimally invasive implant placement.
Accuracy and the role of experience in dynamic computer guided dental implant surgery: an in-vitro study
2019
Background To compare the accuracy of implant placement using the conventional freehand method and a dynamic navigation system; to assess the role of the surgeon’s experience in implant placement using these two methods. Material and Methods A randomized in-vitrostudy was conducted. Six resin mandible models and 36 implants were used. Two researchers with differing clinical experience (novice and experienced) placed implants using either the Navident dynamic navigation system (navigation group) or the conventional freehand method (freehand group). Accuracy was measured by overlaying the real position in the postoperative CBCT on the virtual presurgical placement of the implant in a CBCT ima…
Prosthetically‐Driven Full‐Mouth Implant‐Supported Prostheses Using Guided Surgical Implant Planning with Composite Resin Markers: A Case Report
2021
This report describes a prosthetically-driven implant planning method, guided by the alignment procedures between the cone beam computed tomography, intraoral digital scans, and digitized maxillary and mandibular interim complete dentures using intraoral composite resin markers as a common reference. The markers were attached to the keratinized oral mucosa of the edentulous ridges using cyanoacrylate and kept in place during the digitizing procedures. The technique provides a simpler and more economical alternative to conventional prosthetically-driven static implant planning methods.