Search results for "DEPTH"
showing 10 items of 408 documents
Hydraulic jumps at drop and abrupt enlargement in rectangular channel
2002
The different types of hydraulic jumps that occur in a rectangular channel at an abrupt increase in section are experimentally studied. The abrupt section increase is due to both a drop and an increase in the channel width. Experiments were carried out with three different values of the ratio L/l between the channel widths respectively downstream and upstream of the abrupt section increase. For each L/l value five values of Froude number F1, of the supercritical flow upstream of the section increase were considered, and for each of them live values of the depth y1 of the same flow. The experiments showed that, as the depth y2 of the downstream subcritical flow increases, several types of hy…
Mass absorption indices of various types of natural aerosol particles in the infrared
2010
The mass absorption index of aerosol particles has been measured in the 2-17-microm wavelength region. The measurements were performed on films of aerosol particles that were collected by an automatic jet impactor at polluted and various uncontaminated remote sites. All but marine aerosols possess strong absorption bands in the transparent part of the atmospheric long-wave spectrum, indicating marked influence of aerosol particles on the radiation budget of the atmosphere.
FIMic: design for ultimate 3D-integral microscopy of in-vivo biological samples
2018
In this work, Fourier integral microscope (FIMic), an ultimate design of 3D-integral microscopy, is presented. By placing a multiplexing microlens array at the aperture stop of the microscope objective of the host microscope, FIMic shows extended depth of field and enhanced lateral resolution in comparison with regular integral microscopy. As FIMic directly produces a set of orthographic views of the 3D-micrometer-sized sample, it is suitable for real-time imaging. Following regular integral-imaging reconstruction algorithms, a 2.75-fold enhanced depth of field and [Formula: see text]-time better spatial resolution in comparison with conventional integral microscopy is reported. Our claims …
Generation and excitation of point defects in silica by synchrotron radiation above the absorption edge
2010
We report photoluminescence measurements carried out on amorphous SiO{sub 2} upon excitation by synchrotron light. Exposure of the as-grown material to above-edge light at low temperature induces the formation of nonbridging oxygen hole centers (NBOHC), localized in a thin layer below the surface limited by the penetration depth (tens of nm) of impinging light. After concluding the exposure to 11 eV light, stable defects are revealed by observing their characteristic 1.9 eV photoemission band excited at 4. 8eV. The local concentration of induced defects, supposedly formed by nonradiative decay of excitons, is very high (close to approx10{sup 21} cm{sup -3}) and independent of the previous h…
Linking structure and nanomechanical properties via instrumented nanoindentations on well-defined and fine-tuned morphology poly(ethylene)
2009
Several poly(ethylene) samples with a broad range of morphologies were studied in this work using nanoindentations. The samples had degrees of crystallinity ranging from 30 to 100% while their Young's modulus ranged from few tens of MPa up to several GPa. Experimental conditions for the correct evaluation of Young's modulus were at first identified, choosing a suitable loading rate in order to minimize viscoelastic effects on the unloading. The force curves, i.e., plots of applied load vs. penetration depth, were then analyzed following two common procedures available in the literature. None of these procedures leads to satisfying results when compared to other experimental techniques. Howe…
Influence of a Crosslinker Containing an Azo Group on the Actuation Properties of a Photoactuating LCE System
2016
Photoactuating liquid crystalline elastomers (LCE) are promising candidates for an application as artificial muscles in microdevices. In this work, we demonstrate that by optimizing (1) the illumination conditions and (2) the mixture of azo monomer and azo crosslinker, thick films of an all-azo LCE can be prepared, which show a strong length change without bending during photoactuation. This becomes possible by working with white light (about 440 nm), whose absorption is low, leading to a large penetration depth. By adding an azo crosslinker to a previously prepared system, several improvements of the actuation properties—like a stronger photoactuation at lower operational temperatures—coul…
Depth-dose measurement corrections for the surface electronic brachytherapy beams of an Esteya® unit: a Monte Carlo study
2020
Abstract Three different correction factors for measurements with the parallel-plate ionization chamber PTW T34013 on the Esteya electronic brachytherapy unit have been investigated. This chamber type is recommended by AAPM TG-253 for depth-dose measurements in the 69.5 kV x-ray beam generated by the Esteya unit. Monte Carlo simulations using the PENELOPE-2018 system were performed to determine the absorbed dose deposited in water and in the chamber sensitive volume at different depths with a Type A uncertainty smaller than 0.1%. Chamber-to-chamber differences have been explored performing measurements using three different chambers. The range of conical applicators available, from 10 to 30…
Fractal photon sieve
2006
A novel focusing structure with fractal properties is presented. It is a photon sieve in which the pinholes are appropriately distributed over the zones of a fractal zone plate. The focusing properties of the fractal photon sieve are analyzed. The good performance of our proposal is demonstrated experimentally with a series of images obtained under white light illumination. It is shown that compared with a conventional photon sieve, the fractal photon sieve exhibits an extended depth of field and a reduced chromatic aberration.
Statistical prediction of corrosion front penetration
1997
A statistical method to predict the stochastic evolution of corrosion fronts has been developed. The method is based on recording material loss and maximum front depth. In this paper we introduce the method and test its applicability. In the absence of experimental data we use simulation data from a three-dimensional corrosion model for this test. The corrosion model simulates localized breakdown of a protective oxide layer, hydrolysis of corrosion product and repassivation of the exposed surface. In the long time limit of the model, pits tend to coalesce. For different model parameters the model reproduces corrosion patterns observed in experiment. The statistical prediction method is base…
Comprehensive formulation of temperature-dependent dispersion of optical materials: illustration with case of temperature tuning of a mid-IR HgGa_2S_…
2009
The temperature dependence of refractive indices of optical materials is characterized in this work by what we call their normalized thermo-optic coefficients. These are determined experimentally through interferometric measurements of thermal expansion and of changes in optical thickness at a few laser wavelengths as function of temperature. A suitable vectorial formalism applied to these data allows predicting the thermal evolution of the refractive index all over the useful range of transparency. The validity and reliability of our methodology is demonstrated through temperature tuning of a mid-IR HgGa2S4 optical parametric oscillator (OPO) pumped at 1.0642 μm by a Nd:YAG laser. Measured…