Search results for "DEPTH"
showing 10 items of 408 documents
Visual simulation through different intraocular lenses using adaptive optics: Effect of tilt and decentration
2011
Purpose To analyze visual quality differences between intraocular lenses (IOLs) and assess the impact of IOL decentration and tilt on visual quality. Setting University of Valencia, Valencia, Spain. Design Cohort study. Methods The crx1 adaptive optics visual simulator was used to simulate the wavefront aberration pattern of 2 commercially available aspheric aberration-correcting IOLs (Acrysof IQ SN60WF and Tecnis ZA9003) and 2 spherical IOLs (Akreos Adapt and Triplato) in 5 situations: centered, decentered 0.2 mm and 0.4 mm, and tilted 2 degrees and 4 degrees. Monocular distance visual acuity at 100%, 50%, and 10% contrast and the depth of focus were measured. Results Ten eyes of 10 patien…
Simulated prototype of posterior chamber phakic intraocular lens for presbyopia correction.
2014
Purpose To evaluate the visual impact of adding different spherical aberration values to an Implantable Collamer Lens phakic intraocular lens (pIOL) to increase the depth of focus using an adaptive optics visual simulator. Setting University of Valencia, Valencia, Spain. Design Experimental study. Methods Wavefront aberrations in −3.00 D and −6.00 diopter (D) pIOLs were measured in vitro. Afterward, different simulated pIOL experimental prototypes were created along with variances in the spherical aberration. An adaptive optics visual simulator was used to simulate vision after the implantation of the different pIOL prototypes from their wavefront aberrations. The corrected distance visual …
Depth of focus through different intraocular lenses in patients with different corneal profiles using adaptive optics visual simulation
2011
PURPOSE: To evaluate the depth of focus with monofocal intraocular lenses (IOLs) in patients with different corneal profiles using adaptive optics (AO) visual simulation. METHODS: An AO visual simulator (crx1, Imagine Eyes) was used to simulate the aberration pattern of three monofocal IOLs (Acrysof IQ SN60WF [Alcon Laboratories Inc]; Akreos Adapt AO [Bausch & Lomb]; and Triplato [AJL Ophthalmic]) of different optic designs. Five groups were considered: patients without any corneal refractive surgery (normal cornea group) and with prior low and high myopic and hyperopic ablations (low myopic ablation, high myopic ablation, low hyperopic ablation, and high hyperopic ablation groups). De…
Typologies and precursors of career adaptability patterns among emerging adults: a seven-year longitudinal study.
2013
The present study examined career adaptability in 100 Israeli emerging adults who were followed from ages 22 to 29. Participants were given an in depth interview and were asked to talk about their current work, difficulties they might have had in the past and how they coped with them. In addition they were asked to elaborate on the extent to which their job fits their interests and is meaningful to them. Analyses of interviews yielded three distinctive career adaptability patterns that were associated with different levels of concurrent wellbeing: Integrated, Compromised, and Vague. A lower level of identified motivation measured seven years earlier predicted membership in the Compromised p…
The effect of longitudinal chromatic aberration on the lag of accommodation and depth of field.
2016
Purpose Longitudinal chromatic aberration is present in all states of accommodation and may play a role in the accommodation response and the emmetropisation process. We study the change of the depth of field (DOFi) with the state of accommodation, taking into account the longitudinal chromatic aberration. Methods Subjective DOFi was defined as the range of defocus beyond which the blur of the target (one line of optotypes of 0.1 logMAR shown on a black-and-white microdisplay, seen through different colour filters) was perceived as objectionable. The subject's eye was paralysed and different, previously-measured accommodative states (corresponding to the accommodative demands of 0D, 2D and …
Illusory contours from pictorially three-dimensional inducing elements: counterevidence for Parks and Rock's example.
1993
In 1990 Parks and Rock claimed that, in pictorially three-dimensional (3-D) inducing patterns, an illusory figure does not emerge if a clear occlusion event is not present. A new pictorially 3-D pattern is presented which contradicts this claim. Two experiments were carried out. The first was aimed at ascertaining the presence of an illusory figure in the new 3-D pattern; the second was aimed at offering evidence that in Parks and Rock's pattern the disappearance of the illusory figure could be due to local interferences caused by the line elements in contact with the inducing borders. The results tend to contradict Parks and Rock's conclusions.
A Slippery Slope: Estimated Slant of Hills Increases with Distance
2014
The slopes of hills tend to be greatly overestimated. Previous studies have found that slope estimates are significantly greater when estimated verbally than with a proprioceptive measure. It has yet to be determined whether these estimates are made for the entire extent of the slope, or whether the estimates in closest proximity are estimated using a different process. Since some parietal cortex neurons respond differently to objects within arm's reach, short-distance slope estimation may utilize these or analogous neurons. Alternatively, greater implied effort might make longer slopes seem steeper. We determined that both verbal and proprioceptive reports of slope are overestimates that …
The effect of aberrations on objectively assessed image quality and depth of focus
2017
The effects of aberrations on image quality and the objectively assessed depth of focus (DoF) were studied. Aberrometry data from 80 young subjects with a range of refractive errors was used for computing the visual Strehl ratio based on the optical transfer function (VSOTF), and then, through-focus simulations were performed in order to calculate the objective DoF (using two different relative thresholds of 50% and 80%; and two different pupil diameters) and the image quality (the peak VSOTF). Both lower order astigmatism and higher order aberration (HOA) terms up to the fifth radial order were considered. The results revealed that, of the HOAs, the comatic terms (third and fifth order) ex…
Optical factors influencing the amplitude of accommodation
2017
AbstractThe purpose of this work was to find plausible predictors among optical parameters that may explain the inter-individual differences in subjective amplitude of accommodation not explained by age. An exploratory multivariable regression analysis was carried out retrospectively on a dataset with 180 eyes from 97 subjects (ages ranged from 20 to 58years). Subjective amplitudes of accommodation were recorded with the use of a custom-made Badal system. A commercial aberrometer was used to obtain each eye’s wavefront during the full range of accommodation. The plausible predictors under study were pupil diameter in the unaccommodated eye, its reduction with accommodation; fourth- and six-…
Three-dimensional (3D) versus two-dimensional (2D) laparoscopic adrenalectomy: A case-control study
2016
Abstract Introduction Laparoscopic adrenalectomy is today considered the gold standard of treatment for adrenal tumors. The development of high definition cameras does not eliminate the major limitation of two-dimensional (2D) laparoscopy: lack of depth perception and loss of spatial orientation. Tree-dimensional (3D) HD laparoscopy was developed as an alternative to conventional 2D laparoscopy. Methods We report our experience with use of 3D vision system for laparoscopic adrenalectomy. Between January 2009 and March 2015 we performed a total of 52 laparoscopic adrenalectomies. In this case-control study we considered 13 laparoscopic adrenalectomies performed with three-dimensional (3D) vi…