Search results for "DETECT"

showing 10 items of 5902 documents

Efficient transfer of positrons from a buffer-gas-cooled accumulator into an orthogonally oriented superconducting solenoid for antihydrogen studies

2012

Positrons accumulated in a room-temperature buffer-gas-cooled positron accumulator are efficiently transferred into a superconducting solenoid which houses the ATRAP cryogenic Penning trap used in antihydrogen research. The positrons are guided along a 9 m long magnetic guide that connects the central field lines of the 0.15 T field in the positron accumulator to the central magnetic field lines of the superconducting solenoid. Seventy independently controllable electromagnets are required to overcome the fringing field of the large-bore superconducting solenoid. The guide includes both a 15° upward bend and a 105° downward bend to account for the orthogonal orientation of the positron accu…

Antiparticlesuperconductivity [solenoid]Physics::Instrumentation and DetectorsPenning trapGeneral Physics and Astronomybeam transportSuperconducting magnetlaw.inventionenergy spectrum [positron]Nuclear physicslawddc:530AntihydrogenPhysicsElectromagnetspatial distribution [magnetic field]ATRAPPenning trapMagnetic fieldbeam opticscryogenicsAntimatterMagnetPhysics::Accelerator Physicsaccumulator [positron]Atomic physicsperformanceNew Journal of Physics
researchProduct

Study on the sensitive and selective adsorption voltammetry of vanadium with antipyrylazo III (APA III)

1994

The sensitive and selective adsorption voltammetric determination of the vanadium(V)-antipyrylazoIII complex in HAc-NaAc solution is investigated. The V-complex is strongly adsorbed onto a stationary Hg-electrode and is reduced at a potential more negative than that corresponding to the reduction of its ligand. The conditions for determining vanadium are investigated and the mechanism of the reduction peak of the vanadium complex is discussed, as also the influence of foreign ions on the determination of vanadium. An at least 20-fold excess of foreign ions does not cause any interference. The detection limit is 4×10−10 mol/l V with 3 min enrichment time.

Antipyrylazo IIIDetection limitAdsorptionchemistryLigandSelective adsorptionInorganic chemistryVanadiumchemistry.chemical_elementBiochemistryVoltammetryAnalytical ChemistryIonFresenius' Journal of Analytical Chemistry
researchProduct

Computer-aided-diagnosis for ocular abnormalities from a single color fundus photography with deep learning

2023

Any damage to the retina can lead to severe consequences like blindness. This visual impairment is preventable by early detection of ocular abnormalities. Computer-aided diagnosis (CAD) for ocular abnormalities is built by analyzing retinal imaging modalities, for instance, Color Fundus Photography (CFP). The main objectives of this thesis are to build two CAD models, one to detect the microaneurysms (MAs), the first visible symptom of diabetic retinopathy, and the other for multi-label detection of 28 ocular abnormalities consisting of frequent and rare abnormalities from a single CFP by using deep learning-based approaches. Two methods were proposed for MAs detection: ensemble-based and c…

Apprentissage profondTraitement des imagesAnomalies oculairesImage processingMicroaneurysms detectionOcular abnormalities[INFO.INFO-TS] Computer Science [cs]/Signal and Image ProcessingDétection de microanévrismesDeep learningMulti-Label detectionComputer-Aided-DiagnosisDiagnostic automatiqueDétection multi-Étiquettes
researchProduct

Reliable polygonal approximations of imaged real objects through dominant point detection

1998

Abstract The problem of dominant point detection is posed, taking into account what usually happens in practice. The algorithms found in the literature often prove their performance with laboratory contours, but the shapes in real images present noise, quantization, and high inter and intra-shape variability. These effects are analyzed and solutions to them are proposed. We will also focus on the conditions for an efficient (few points) and precise (low error) dominant point extraction that preserves the original shape. A measurement of the committed error (optimization error, E 0 ) that takes into account both aspects is defined for studying this feature.

Approximations of πQuantization (signal processing)Corner detectionImage processingCurvatureReal imageEdge detectionArtificial IntelligenceSignal ProcessingPolygonComputer Vision and Pattern RecognitionAlgorithmSoftwareMathematicsPattern Recognition
researchProduct

Chromogenic Chemodosimeter Based on Capped Silica Particles to Detect Spermine and Spermidine

2021

A new hybrid organic–inorganic material for sensing spermine (Spm) and spermidine (Spd) has been prepared and characterized. The material is based on MCM-41 particles functionalized with an N-hydroxysuccinimide derivative and loaded with Rhodamine 6G. The cargo is kept inside the porous material due to the formation of a double layer of organic matter. The inner layer is covalently bound to the silica particles, while the external layer is formed through hydrogen and hydrophobic interactions. The limits of detection determined by fluorimetric titration are 27 µM and 45 µM for Spm and Spd, respectively. The sensor remains silent in the presence of other biologically important amines and is a…

Aqueous solutionsperminesilica particlesChemistryChromogenicGeneral Chemical EngineeringdetectionSpermineArticleSpermidineRhodamine 6GHydrophobic effectlcsh:Chemistrychemistry.chemical_compoundlcsh:QD1-999Covalent bondspermidineGeneral Materials ScienceTitrationNuclear chemistryNanomaterials
researchProduct

Study of Inductive Coupled Hydrogen and Argon Plasma Interaction with SiO2 Glass

2009

This work is devoted to the diagnostics of interaction between hydrogen and argon with the surface of SiO2 glass walls. For diagnostics of the interaction, special high-frequency electrodeless light sources were prepared, filled with pure argon of 1 Torr or argon-hydrogen of total pressure of 1 Torr (Ar/H2 mixing ratio is 9:1). Besides the mostly used spherical and cylindrical lamps, dumbbell type lamps have also been investigated. The spectroscopic and AFM measurements showed that in comparison with pure argon plasma, the argon-hydrogen plasma causes non-uniform changes of the SiO2 surface. For these modifications active OH are primarily responsible molecules, created in the reactions of h…

ArgonPolymers and PlasticsHydrogenPlasma cleaningPhysics::Instrumentation and DetectorsChemistryAnalytical chemistrychemistry.chemical_elementPlasmaCondensed Matter PhysicsPhysics::Plasma PhysicsSurface modificationMoleculePhysics::Atomic PhysicsPhysics::Chemical PhysicsTotal pressureSpectroscopyPlasma Processes and Polymers
researchProduct

Fluorogenic detection of Tetryl and TNT explosives using nanoscopic-capped mesoporous hybrid materials

2013

[EN] A hybrid capped mesoporous material, which was selectively opened in the presence of Tetryl and TNT, has been synthesised and used for the fluorogenic recognition of these nitroaromatic explosives.

Aromatic compoundsINGENIERIA DE LA CONSTRUCCIONMaterials scienceExplosive materialTECNOLOGIA DE ALIMENTOSInorganic chemistryNanotechnologyNitroaromatic explosivesSilica nanoparticleschemistry.chemical_compoundNitroaromatic explosivesQUIMICA ORGANICAExplosives detectionQUIMICA ANALITICAGeneral Materials ScienceNanoscopic scaleRenewable Energy Sustainability and the EnvironmentQUIMICA INORGANICAGeneral ChemistryTetrylSilica nanoparticlesMesoporous materialsFluorogenicschemistryMesoporous hybridsHybrid materialsHybrid materialMesoporous material
researchProduct

Comparative analysis in terms of computational cost for different discrimination algorithms in implantable defibrillators

2005

Implantable defibrillators (ICDs) use very low computational cost criteria (rate, stability and onset) offering good sensitivity for arrhythmia detection. Although, the specificity of these combined criteria decreases in difficult arrhythmia discrimination as in case of discrimination between ventricular tachycardia (VT) and supraventricular tachycardia (SVT). Several morphological published algorithms enhance arrhythmia discrimination but most algorithms are developed in personal computers and cannot be used in ICDs because of computational cost requirements compared with limited ICD capabilities. A general method to determine the possibility of ICD implementation for a discrimination algo…

Arrhythmia detectionGeneral methodbusiness.industrycardiovascular systemStability (learning theory)Medicinecardiovascular diseasesSupraventricular tachycardiabusinessmedicine.diseaseVentricular tachycardiaAlgorithmImplantable defibrillatorsComputers in Cardiology, 2004
researchProduct

An offline/real-time artifact rejection strategy to improve the classification of multi-channel evoked potentials

2008

The primary goal of this paper is to improve the classification of multi-channel evoked potentials (EPs) by introducing a temporal domain artifact detection strategy and using this strategy to (a) evaluate how the performance of classifiers is affected by artifacts and (b) show how the performance can be improved by detecting and rejecting artifacts in offline and real-time classification experiments. Using a pattern recognition approach, an artifact is defined in this study as any signal that may lead to inaccurate classifier parameter estimation and inaccurate testing. The temporal domain artifact detection tests include: a within-channel standard deviation (STD) test that can detect sign…

Artifact rejectionArtificial IntelligenceEstimation theoryComputer scienceSpeech recognitionSignal ProcessingInformation processingDetection theoryComputer Vision and Pattern RecognitionEvoked potentialClassifier (UML)SoftwareStandard deviationPattern Recognition
researchProduct

Effect of the high-level trigger for detecting long-lived particles at LHCb.

2022

Long-lived particles (LLPs) show up in many extensions of the Standard Model, but they are challenging to search for with current detectors, due to their very displaced vertices. This study evaluated the ability of the trigger algorithms used in the Large Hadron Collider beauty (LHCb) experiment to detect long-lived particles and attempted to adapt them to enhance the sensitivity of this experiment to undiscovered long-lived particles. A model with a Higgs portal to a dark sector is tested, and the sensitivity reach is discussed. In the LHCb tracking system, the farthest tracking station from the collision point is the scintillating fiber tracker, the SciFi detector. One of the challenges i…

Artificial IntelligenceComputer Science (miscellaneous)FísicaDetectors and Experimental TechniquesComputing and ComputersInformation SystemsFrontiers in big data
researchProduct