Search results for "DETECT"
showing 10 items of 5902 documents
Immuno-MALDI-MS in Human Plasma and on-Chip Biomarker Characterizations at the Femtomole Level
2012
Immuno-SPR-MS is the combination of immuno-sensors in biochip format with mass spectrometry. This association of instrumentation allows the detection and the quantification of proteins of interest by SPR and their molecular characterization by additional MS analysis. However, two major bottlenecks must be overcome for a wide diffusion of the SPR-MS analytical platform: (i) To warrant all the potentialities of MS, an enzymatic digestion step must be developed taking into account the spot formats on the biochip and (ii) the biological relevancy of such an analytical solution requires that biosensing must be performed in complex media. In this study, we developed a procedure for the detection …
Salt release monitoring with specific sensors in "in vitro" oral and digestive environments from soft cheeses
2012
International audience; The objective of the present work is to demonstrate the interest and the feasibility of the measurement of NaCl concentrations in soft cheeses and in particular an in vitro digestion process by the use of chemical sensors. The analyzed matrices were the commercial Italian mozzarella cheeses and domestic cheese base models. The classification of mozzarellas was performed according to their salinity, while the breakdown of cheese base models has been followed both at initial steps of digestion in artificial mouth dispositive mimicking the oral sphere and in a gut-imitating digester (TIM-1). During the breakdown of soft cheese in the digester, the estimated values for N…
Screening of complicated grief
2013
Objetivo: Conocer en profundidad el fenómeno del duelo complicado o patológico, y recabar aquellos indicadores de detección y evaluación que nos permitan su pronta identificación en la práctica clínica. Método: Tras una amplia revisión de la literatura científica aparecida en los últimos años, y a la luz de nuestra experiencia profesional, se realizó una recopilación de los indicadores más significativos. Resultados: Presentamos los principales criterios diagnósticos e instrumentos de medida utilizados en la actualidad, que permiten a los profesionales del ámbito de la salud valorar con precisión posibles complicaciones en el proceso de duelo. Conclusiones: Contamos con importantes indicado…
PCB-Based Planar Inductive Loops for Partial Discharges Detection in Power Cables
2022
Partial discharge (PD) diagnosis tests, including detecting, locating, and identifying, are used to trace defects or faults and assess the degree of aging in order to monitor the insulation condition of medium- and high-voltage power cables. In this context, an experimental evaluation of three different printed circuit board (PCB)-based inductive sensor topologies, with spiral, non-spiral, and meander shapes, is performed. The aim is to assess their capabilities for PD detection along a transmission power cable. First, simulation and experimental characterization are carried out to determine the equivalent electrical circuit and the quality factor of the three sensors. PD activity was studi…
Theoretical study of neutrino scattering off the stable even Mo isotopes at low and intermediate energies
2011
A systematic study of the cross sections of neutral-current neutrino scattering off the stable even Mo isotopes (mass number A = 92, 94, 96, 98, 100), at low and intermediate neutrino energies (E(nu) <= 130 MeV), is presented and discussed. The required wave functions for the initial (ground state) and all accessible final nuclear states are constructed in the context of the quasi-particle random-phase approximation (QRPA) and tested against data on the low-lying energy spectra of the isotopes in question. The individual contributions coming from the polar-vector and axial-vector components of the hadronic current for the coherent and incoherent channels of each isotope are investigated. Th…
The arsenic content of human semen.
2009
Arsenic concentration was measured by atomic absorption spectrometer in ejaculates of 13 subfertile men, 6 control individuals and pool-ejaculate of 24 further andrological patients. While the detection limit was 1 microgram/l, arsenic concentration amounted to 2 micrograms AS/l in ejaculates. In the cellular fractions of seminal fluid, concentration of arsenic was under the detection limit. Arsenic concentration of smokers and non-smokers did not differ.
Determination of selenium, zinc and cadmium in antidandruff shampoos by atomic spectrometry after microwave assisted sample digestion
2000
Microwave assisted pre-treatments for atomic spectrometric determination (inductive coupled plasma-optical emission spectrometry, ICP-OES or flame atomic absorption spectrometry, FAAS) of metallic elements, usually present in antidandruff shampoos, are proposed. They are based on the digestion of the sample with HNO(3) into a closed reactor, which is irradiated at 800 W for a few minutes. Selenium was determined by ICP-OES. The limit of detection was 0.11 mg l(-1); the relative standard deviation (R.S.D.) for the selenium content in the samples was in the 0.6-3.6% range. The results obtained were in agreement with the label contents and the recovery of the proposed method was in the 100-106…
Electrothermal Atomic Absorption Determination of Chromium in Sediments
1999
Abstract An electrothermal atomic absorption spectrometric method has been developed to determine total chromium concentration in natural sediment samples. Samples were mineralized by dry ashing at 550°C and fused at 1100°C for 30 min with lithium metaborate. Dissolved samples were injected in graphite tubes, mineralized at 1100°C, and atomized at 2600°C. Standard addition calibration made unnecessary the use of chemical modifiers. The method provided a limit of detection from 23 to 45 ng liter −1 . The relative standard deviation for chromium determination was between 3 and 14%. Results obtained for a standard reference material agree well with the certified value. A series of natural samp…
A new simple chromo-fluorogenic probe for NO2 detection in air.
2015
[EN] A new chromo-fluorogenic probe, consisting of a biphenyl derivative containing both a silylbenzyl ether and a N,N-dimethylamino group, for NO2 detection in the gas phase has been developed. A clear colour change from colourless to yellow together with an emission quenching was observed when the probe reacted with NO2. A limit of detection to the naked eye of about 0.1 ppm was determined and the system was successfully applied to the detection of NO2 in realistic atmospheric conditions.
Validation of a method for neutron dosimetry and spectrometry using neutron activation of metal discs
2009
A technique for neutron dosimetry and spectrometry based on neutron activation of different metal discs has been studied. After exposure to a neutron field, the radionuclides produced in the discs are detected using low-level gamma-ray spectrometry and the neutron spectrum is obtained using a spectrum unfolding technique. In order to validate the method, irradiation was performed in a well-characterised (252)Cf neutron reference field. Furthermore, the detector was used to determine the neutron fluence rate and spectrum at a storage place for MOX nuclear fuel. The results of the two measurements are reported and discussed.