Search results for "DETECT"
showing 10 items of 5902 documents
Mapping of the magnetic field to correct systematic effects in a neutron electric dipole moment experiment
2021
Experiments dedicated to the measurement of the electric dipole moment of the neutron require outstanding control of the magnetic-field uniformity. The neutron electric dipole moment (nEDM) experiment at the Paul Scherrer Institute uses a Hg199 co-magnetometer to precisely monitor temporal magnetic-field variations. This co-magnetometer, in the presence of field nonuniformity, is, however, responsible for the largest systematic effect of this measurement. To evaluate and correct that effect, offline measurements of the field nonuniformity were performed during mapping campaigns in 2013, 2014, and 2017. We present the results of these campaigns, and the improvement the correction of this eff…
STATUS OF STRANGENESS ELECTRO-PRODUCTION AT MAMI
2009
At the Institut für Kernphysik in Mainz, Germany, the microtron MAMI has been upgraded to 1.5 GeV electron beam energy and can now be used to study strange hadronic systems. The magnetic spectrometer KAOS from GSI was dismantled and re-installed in the spectrometer facility operated by the A1 collaboration. The spectrometer's primary purpose is to study strangeness electro-production. Its compact design and its capability to detect negative and positive charged particles simultaneously under forward scattering angles complements the existing spectrometers. In 2008, an important milestone has been reached by the successful measurement of kaon production off a liquid hydrogen target. The ide…
Automatic Processing of Changes in Facial Emotions in Dysphoria: A Magnetoencephalography Study
2018
It is not known to what extent the automatic encoding and change detection of peripherally presented facial emotion is altered in dysphoria. The negative bias in automatic face processing in particular has rarely been studied. We used magnetoencephalography (MEG) to record automatic brain responses to happy and sad faces in dysphoric (Beck’s Depression Inventory ≥ 13) and control participants. Stimuli were presented in a passive oddball condition, which allowed potential negative bias in dysphoria at different stages of face processing (M100, M170, and M300) and alterations of change detection (visual mismatch negativity, vMMN) to be investigated. The magnetic counterpart of the vMMN was el…
Magnetoencephalography Responses to Unpredictable and Predictable Rare Somatosensory Stimuli in Healthy Adult Humans
2021
Mismatch brain responses to unpredicted rare stimuli are suggested to be a neural indicator of prediction error, but this has rarely been studied in the somatosensory modality. Here, we investigated how the brain responds to unpredictable and predictable rare events. Magnetoencephalography responses were measured in adults frequently presented with somatosensory stimuli (FRE) that were occasionally replaced by two consecutively presented rare stimuli [unpredictable rare stimulus (UR) and predictable rare stimulus (PR); p = 0.1 for each]. The FRE and PR were electrical stimulations administered to either the little finger or the forefinger in a counterbalanced manner between the two conditio…
Triacylglycerol Analysis in Human Milk and Other Mammalian Species: Small-Scale Sample Preparation, Characterization, and Statistical Classification …
2015
In this work, a method for the separation of triacylglycerols (TAGs) present in human milk and from other mammalian species by reversed-phase high-performance liquid chromatography using a core–shell particle packed column with UV and evaporative light-scattering detectors is described. Under optimal conditions, a mobile phase containing acetonitrile/n-pentanol at 10 °C gave an excellent resolution among more than 50 TAG peaks. A small-scale method for fat extraction in these milks (particularly of interest for human milk samples) using minimal amounts of sample and reagents was also developed. The proposed extraction protocol and the traditional method were compared, giving similar results…
Direct mass measurements on neutron-deficient xenon isotopes with the ISOLTRAP mass spectrometer
2002
The masses of Xe isotopes with 124 A 114 have been measured using the ISOLTRAP spectrometer at the on-line mass separator ISOLDE/CERN. A mass resolving power of 500000 was chosen resulting in an accuracy of m 12 keV for all isotopes investigated. Con icts with existing mass data of several standard deviations were found. peerReviewed
Status and development of the MARA low-energy branch
2018
The MARA Low-Energy Branch is under development at the Accelerator Laboratory of the University of Jyvaskylä. The facility will be employed for laser ionisation and spectroscopy studies and for mass measurements of nuclei close to the proton drip line. This article presents an updated status of the ongoing development of the different parts of this facility, including the buffer gas cell, the ion transport system, the laser system and the detector stations. peerReviewed
SPI/INTEGRAL in-flight performance
2003
The SPI instrument has been launched on-board the INTEGRAL observatory on October 17, 2002. SPI is a spectrometer devoted to the sky observation in the 20 keV-8 MeV energy range using 19 germanium detectors. The performance of the cryogenic system is nominal and allows to cool the 19 kg of germanium down to 85 K with a comfortable margin. The energy resolution of the whole camera is 2.5 keV at 1.1 MeV. This resolution degrades with time due to particle irradiation in space. We show that the annealing process allows the recovery of the initial performance. The anticoincidence shield works as expected, with a low threshold at 75 keV, reducing the GeD background by a factor of 20. The digital …
Data from: Quality attracts parasites: host condition-dependent chemo-orientation of trematode larvae
2014
1. Environmental factors impairing physiological condition of organisms are assumed to predispose them to parasite infections. This is because host immune function is typically condition-dependent. However, poor physiological condition has been reported to reduce host susceptibility to parasites in various systems. 2. We examined whether such an effect can be due to altered exposure of hosts to active parasite transmission stages by investigating chemo-orientation of free-swimming cercariae larvae of a parasite Echinoparyphium aconiatum towards its snail host Lymnaea stagnalis. 3. We used both long-term and short-term feeding treatments to manipulate the body condition and physiological tra…
Optical multichannel monitoring of skin blood pulsations for cardiovascular assessment
2004
Time resolved detection and analysis of the skin back-scattered optical signals (reflection photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for cardiovascular assessment. The multichannel PPG concept has been developed and clinically verified in this work. Simultaneous data flow from several body locations allows to study the heartbeat pulse wave propagation in real time and to evaluate the vascular resistance. Portable two- and four-channel PPG monitoring devices and special software have been designed for real-time data acquisition and processing. The multi-channel devices were successfully applied for cardiovascular fitness tests and fo…