Search results for "DETECTION"

showing 10 items of 2543 documents

Spectrophotometric determination of ethiofencarb in waters by reaction with p-aminophenol

1993

An automatized procedure has been developed for the spectrophotometric determination of ethiofencarb in water by reaction with p-aminophenol after alkaline hydrolysis to obtain the corresponding phenol sulphone. The hydrolyzed samples are continuously introduced into different manifolds at the same time as 300 mg/l p-aminophenol, 0.004 mol/l KIO4 and 0.04 mol/l NaOH solutions. The absorbance is measured at 638 nm after a reaction time of 6 min in stop flow. This absorbance band corresponds to the indo dye obtained from the reaction between the phenol sulphone of ethiofencarb and the quinoneimine form of the p-aminophenol and it permits a matrix-free spectrophotometric determination of ethio…

AbsorbanceDetection limitHydrolysischemistry.chemical_compoundChemistryP-AminophenolEthiofencarbAnalytical chemistryPhenolAlkaline hydrolysis (body disposal)BiochemistryChemical reactionNuclear chemistryFresenius' Journal of Analytical Chemistry
researchProduct

Development of microextraction techniques in combination with GC-MS/MS for the determination of mycotoxins and metabolites in human urine.

2017

Simple and highly efficient sample preparation procedures, namely, dispersive liquid–liquid microextraction and salting-out liquid–liquid extraction for the analysis of ten Fusarium mycotoxins and metabolites in human urine were compared. Various parameters affecting extraction efficiency were carefully evaluated. Under optimal extraction conditions, salting-out liquid–liquid extraction showed a better accuracy (84–96%) and precision (<14%) than dispersive liquid–liquid microextraction. Hence, a multibiomarker method based on salting-out liquid–liquid extraction followed by gas chromatography with tandem mass spectrometry was proposed. Satisfactory results in terms of validation were achiev…

Accuracy and precisionLiquid Phase MicroextractionFiltration and SeparationPilot ProjectsUrineUrinalysisTandem mass spectrometry01 natural sciencesGas Chromatography-Mass SpectrometryAnalytical Chemistry0404 agricultural biotechnologyLimit of DetectionTandem Mass SpectrometryHumansSample preparationDetection limitChromatographyChemistry010401 analytical chemistryExtraction (chemistry)04 agricultural and veterinary sciencesMycotoxins040401 food science0104 chemical sciencesGas chromatographyGas chromatography–mass spectrometryJournal of separation science
researchProduct

Isocratic high-performance liquid chromatographic determination of tryptophan in infant formulas.

1996

The application to infant formulas of a method for tryptophan determination by isocratic HPLC with UV detection at 254 nm, after derivatization with phenyl isothiocyanate, was studied. Protein was hydrolysed by barium hydroxide at 120 degrees C for 8 h, followed by derivatization with phenyl isothiocyanate, HPLC and UV detection at 254 nm. The optimum chromatographic conditions (pH, ionic strength of elution solvent and eluent ratio) were established. The analytical parameters (linearity, precision, accuracy of derivatization and limits of detection and quantification) were determined. The values obtained demonstrated that the method is useful for determining the tryptophan content of infan…

AcetatesBiochemistryHigh-performance liquid chromatographySensitivity and SpecificityAnalytical ChemistryBarium hydroxidechemistry.chemical_compoundColumn chromatographyIsothiocyanatesHumansDerivatizationChromatography High Pressure LiquidAcetic AcidDetection limitChromatographyPhenyl isothiocyanateElutionOrganic ChemistryOsmolar ConcentrationTryptophanInfant NewbornTryptophanInfantGeneral MedicineHydrogen-Ion ConcentrationchemistrySolventsInfant FoodThiocyanatesJournal of chromatography. A
researchProduct

Determination of free formaldehyde in cosmetics containing formaldehyde-releasing preservatives by reversed-phase dispersive liquid-liquid microextra…

2017

Abstract An analytical method for the determination of traces of formaldehyde in cosmetic products containing formaldehyde-releasing preservatives has been developed. The method is based on reversed-phase dispersive liquid–liquid microextraction (RP-DLLME), that allows the extraction of highly polar compounds, followed by liquid chromatography–ultraviolet/visible (LC–UV/vis) determination with post-column derivatization. The variables involved in the RP-DLLME process were studied to provide the best enrichment factors. Under the selected conditions, a mixture of 500 μL of acetonitrile (disperser solvent) and 50 μL of water (extraction solvent) was rapidly injected into 5 mL of toluene sampl…

AcetonitrilesLiquid Phase Microextraction02 engineering and technologyCosmetics01 natural sciencesBiochemistryChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundLimit of DetectionFormaldehydeAcetonitrileDerivatizationDetection limitChromatographyElution010401 analytical chemistryOrganic ChemistryExtraction (chemistry)Preservatives PharmaceuticalReproducibility of ResultsWaterGeneral Medicine021001 nanoscience & nanotechnology0104 chemical sciencesSolventchemistryReagentSolvents0210 nano-technologyEnrichment factorChromatography LiquidTolueneJournal of chromatography. A
researchProduct

A capillary liquid chromatography method for benzalkonium chloride determination as a component or contaminant in mixtures of biocides

2015

A method for quantifying benzalkonium chloride (BAK), an alkyl dimethyl benzyl ammonium compound, in several biocides formulations is proposed. A tertiary amine like N-(3-aminopropyl)-N-dodecyl-1,3-propanediamine (TA) and a straight-chain alkyl ammonium compound like trimethyl-tetradecyl ammonium chloride (TMTDAC), have been employed as trade surfactants besides BAK. Two capillary analytical columns with different polarities are tested: inertsil CN-3 capillary column (150mm×0.5mm i.d., 3μm particle diameter) and a non endcapped Zorbax C18 capillary column (35mm×0.5mm i.d., 5μm particle diameter). This latter column provided the best separation of the BAK homologues in less than 12min using …

AcetonitrilesTertiary amineCapillary action02 engineering and technologySolid-phase microextraction01 natural sciencesBiochemistryChemistry Techniques AnalyticalAnalytical ChemistrySurface-Active Agentschemistry.chemical_compoundBenzalkonium chlorideLimit of DetectionmedicineAmmoniumAcetonitrileSolid Phase MicroextractionAlkylchemistry.chemical_classificationChromatography010401 analytical chemistryOrganic ChemistryGeneral Medicine021001 nanoscience & nanotechnology0104 chemical scienceschemistryAmmonium chlorideBenzalkonium Compounds0210 nano-technologyChromatography LiquidDisinfectantsmedicine.drugJournal of Chromatography A
researchProduct

Sample Preparation Improvement in Polycyclic Aromatic Hydrocarbons Determination in Olive Oils by Gel Permeation Chromatography and Liquid Chromatogr…

2005

Abstract The determination of 15 polycyclic aromatic hydrocarbons (PAHs) in olive oil samples has been improved in order to obtain a fast methodology with a low limit of detection through the combination of liquid–liquid extraction with acetonitrile and preparative gel permeation chromatography (GPC) prior to the injection of purified extracts into a C18 column. Acetonitrile–water was used as the mobile phase with a gradient from 50 to 95%, w/w, acetonitrile in 30 min. The oven temperature was maintained at 15°C, and fluorometric detection was made at a fixed excitation wavelength of 264 nm and variable, optimal emission wavelength for each analyte ranging from 352 nm for 11-H-benzo(b)fluor…

AcetonitrilesTime FactorsFluoreneChemistry Techniques AnalyticalAnalytical ChemistryGel permeation chromatographychemistry.chemical_compoundPlant OilsEnvironmental ChemistryFluorometryUltrasonicsSample preparationPolycyclic Aromatic HydrocarbonsOlive OilChromatography High Pressure LiquidPharmacologychemistry.chemical_classificationDetection limitFluorantheneFluorenesMethylene ChlorideChromatographyChemistryExtraction (chemistry)TemperatureSilicon DioxideSpectrometry FluorescenceHydrocarbonChromatography GelPyreneAgronomy and Crop ScienceChromatography LiquidFood ScienceJournal of AOAC INTERNATIONAL
researchProduct

A comparison among different techniques for human ERG signals processing and classification

2014

A comparison among different techniques for human ERG signals processing and classification ( Articles not published yet, but available online Article in press About articles in press (opens in a new window) ) Barraco, R.a, Persano Adorno, D.a , Brai, M.a, Tranchina, L.b a Dipartimento di Fisica e Chimica, Università di Palermo and CNISM, Viale delle Scienze, Ed. 18, I-90128 Palermo, Italy b Laboratorio di Fisica e Tecnologie Relative - UniNetLab, Università di Palermo, Viale delle Scienze, Ed. 18, I-90128 Palermo, Italy Abstract Feature detection in biomedical signals is crucial for deepening our knowledge about the involved physiological processes. To achieve this aim, many analytic appro…

Achromatopsiagenetic structuresComputer scienceBiophysicsGeneral Physics and AstronomyColor Vision DefectsPrincipal component analysiWavelet analysisPattern Recognition AutomatedWaveletRetinal pathologieElectroretinographymedicineHumansRadiology Nuclear Medicine and imagingComputer visionFeature detection (computer vision)Principal Component AnalysisSignal processingFourier Analysisbusiness.industryWavelet transformSignal Processing Computer-AssistedPattern recognitionGeneral Medicinemedicine.diseaseSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)eye diseasesERG signalClinical diagnosisPrincipal component analysissense organsArtificial intelligencebusinessErgPhysica Medica
researchProduct

Measurement of acoustic attenuation in South Pole ice

2010

Using the South Pole Acoustic Test Setup (SPATS) and a retrievable transmitter deployed in holes drilled for the IceCube experiment, we have measured the attenuation of acoustic signals by South Pole ice at depths between 190 m and 500 m. Three data sets, using different acoustic sources, have been analyzed and give consistent results. The method with the smallest systematic uncertainties yields an amplitude attenuation coefficient alpha = 3.20 \pm 0.57 km^(-1) between 10 and 30 kHz, considerably larger than previous theoretical estimates. Expressed as an attenuation length, the analyses give a consistent result for lambda = 1/alpha of ~1/300 m with 20% uncertainty. No significant depth or …

Acoustic attenuation; Acoustics; Ice; Neutrino astronomy; South Pole[PHYS.ASTR.HE]Physics [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE]010504 meteorology & atmospheric sciences[SDU.ASTR.CO]Sciences of the Universe [physics]/Astrophysics [astro-ph]/Cosmology and Extra-Galactic Astrophysics [astro-ph.CO]iceFOS: Physical sciencesAetiology screening and detection [ONCOL 5]Lambda01 natural sciencesneutrino astronomy[PHYS.ASTR.CO]Physics [physics]/Astrophysics [astro-ph]/Cosmology and Extra-Galactic Astrophysics [astro-ph.CO]OpticsSpectrum0103 physical sciencesacousticsInstrumentation and Methods for Astrophysics (astro-ph.IM)0105 earth and related environmental sciencesPhysicsSouth Pole010308 nuclear & particles physicsbusiness.industryAttenuation[SDU.ASTR.HE]Sciences of the Universe [physics]/Astrophysics [astro-ph]/High Energy Astrophysical Phenomena [astro-ph.HE]TransmitterAttenuation lengthAstronomy and AstrophysicsGeodesy004AmplitudeAttenuation coefficientddc:540NeutrinoAstrophysics - Instrumentation and Methods for AstrophysicsbusinessAcoustic attenuationinfo:eu-repo/classification/ddc/004acoustic attenuation
researchProduct

Mini-COVIDNet: Efficient Lightweight Deep Neural Network for Ultrasound Based Point-of-Care Detection of COVID-19

2021

Lung ultrasound (US) imaging has the potential to be an effective point-of-care test for detection of COVID-19, due to its ease of operation with minimal personal protection equipment along with easy disinfection. The current state-of-the-art deep learning models for detection of COVID-19 are heavy models that may not be easy to deploy in commonly utilized mobile platforms in point-of-care testing. In this work, we develop a lightweight mobile friendly efficient deep learning model for detection of COVID-19 using lung US images. Three different classes including COVID-19, pneumonia, and healthy were included in this task. The developed network, named as Mini-COVIDNet, was bench-marked with …

Acoustics and UltrasonicsCoronavirus disease 2019 (COVID-19)Computer sciencePoint-of-Care SystemsLatency (audio)detectionlung ultrasound (US) imaging01 natural sciences0103 physical sciencesImage Interpretation Computer-AssistedComputer-Assisted/methodsHumansElectrical and Electronic Engineering010301 acousticsInstrumentationImage InterpretationPoint of careUltrasonographyArtificial neural networkbusiness.industrySARS-CoV-2Deep learningImage Interpretation Computer-Assisted/methodsVDP::Technology: 500COVID-19deep learningUltrasonography/methodsLung ultrasoundCoronavirusTask (computing)point-of-care testingSoftware deploymentEmbedded systemCOVID-19/diagnostic imagingArtificial intelligencebusiness
researchProduct

Knowledge Discovery from Network Logs

2015

Modern communications networks are complex systems, which facilitates malicious behavior. Dynamic web services are vulnerable to unknown intrusions, but traditional cyber security measures are based on fingerprinting. Anomaly detection differs from fingerprinting in that it finds events that differ from the baseline traffic. The anomaly detection methodology can be modelled with the knowledge discovery process. Knowledge discovery is a high-level term for the whole process of deriving actionable knowledge from databases. This article presents the theory behind this approach, and showcases research that has produced network log analysis tools and methods. peerReviewed

Actionable knowledgeKnowledge extractionComputer scienceProcess (engineering)cyber securityComplex systemAnomaly detectionDynamic web pageBaseline (configuration management)kyberturvallisuusData scienceTerm (time)
researchProduct