Search results for "DETECTOR"

showing 10 items of 3491 documents

Pulmonary emphysema in cystic fibrosis detected by densitometry on chest multidetector computed tomography.

2013

BackgroundHistopathological studies on lung specimens from patients with cystic fibrosis (CF) and recent results from a mouse model indicate that emphysema may contribute to CF lung disease. However, little is known about the relevance of emphysema in patients with CF. In the present study, we used computationally generated density masks based on multidetector computed tomography (MDCT) of the chest for non-invasive characterization and quantification of emphysema in CF.MethodsVolumetric MDCT scans were acquired in parallel to pulmonary function testing in 41 patients with CF (median age 20.1 years; range 7-66 years) and 21 non-CF controls (median age 30.4 years; range 4-68 years), and subj…

AdultMalemedicine.medical_specialtyAdolescentCystic FibrosisScienceCystic fibrosisPulmonary function testingHounsfield scaleMultidetector computed tomographyMedicineHumansLung volumesChildAgedEmphysemaMultidisciplinaryLungbusiness.industryQCase-control studyRMiddle Agedrespiratory systemmedicine.diseaserespiratory tract diseasesmedicine.anatomical_structureCase-Control StudiesMedicineFemaleRadiologybusinessDensitometryTomography X-Ray ComputedResearch ArticlePLoS ONE
researchProduct

Cumulative doses analysis in young trauma patients: a single-centre experience

2015

Multidetector computed tomography (MDCT) represents the main source of radiation expo- sure in trauma patients. The radiation exposure of young patients is a matter of considerable medical concern due to possible long-term effects. Multiple MDCT stud- ies have been observed in the young trauma population with an increase in radiation exposure. We have identi- fied 249 young adult patients (178 men and 71 women; age range 14-40 years) who had received more than one MDCT study between June 2010 and June 2014. According to the International Commission on Radio- logical Protection publication, we have calculated the cumulative organ dose tissue-weighting factors by using CT-EXPO software ® . We…

AdultMalemedicine.medical_specialtyAdolescentPopulationDose distributionRadiation DosageEffective dose (radiation)030218 nuclear medicine & medical imagingYoung Adult03 medical and health sciences0302 clinical medicineMultidetector Computed TomographyMultidetector computed tomographymedicineHumansRadiology Nuclear Medicine and imagingYoung adulteducationNeuroradiologyEffective doseeducation.field_of_studymedicine.diagnostic_testbusiness.industryAdsorbed dose; Cumulative doses; Effective dose; MDCT; Tissue-weighting factors; Radiology Nuclear Medicine and ImagingMDCTTissue-weighting factorInterventional radiologyGeneral MedicineCumulative doseSingle centreAdsorbed dose030220 oncology & carcinogenesisWounds and InjuriesFemaleRadiologyNuclear medicinebusinessLa radiologia medica
researchProduct

Early Regeneration of the Remnant Liver Volume after Right Hepatectomy for Living Donation: A Multiple Regression Analysis.

2012

Early liver regeneration was studied in a series of 70 patients who underwent right hepatectomy for living donation between November 2004 and January 2010. Liver regeneration was evaluated with multidetector computed tomography (MDCT) at a mean of 61.07 days after surgery. Presurgical variables [eg, age, weight, height, body mass index (BMI), liver function tests, creatinine levels, platelet counts, international normalized ratio, and glucose levels] and variables detected with preoperative MDCT imaging [eg, main portal vein diameter, steatosis, original liver volume, and spleen volume (SV)] were investigated as potential predictors of liver regeneration. The future remnant liver volume (FR…

AdultMalemedicine.medical_specialtyEarly liver regeneration remnant liver volume right hepatectomy living donationDatabases Factualmedicine.medical_treatmentEarly RegenerationUrologyLiver transplantationBody Mass Indexchemistry.chemical_compoundLiver Function TestsMultidetector Computed TomographyLiving DonorsmedicineHepatectomyHumansRetrospective StudiesTransplantationCreatinineHepatologymedicine.diagnostic_testbusiness.industryLiver DiseasesMiddle Agedmedicine.diseaseLiver regenerationLiver RegenerationLiver TransplantationSurgeryTreatment OutcomeLiverchemistryRegression AnalysisFemaleSurgerySteatosisHepatectomybusinessLiver function testsBody mass index
researchProduct

Emergency radiology: straightening of the cervical spine in MDCT after trauma--a sign of injury or normal variant?

2016

To evaluate whether straightening of the cervical spine (C-spine) alignment after trauma can be considered a significant multidetector CT (MDCT) finding.160 consecutive patients after C-spine trauma admitted to a Level 1 trauma centre received MDCT according to Canadian Cervical Spine Rule and National Emergency X-Radiography Utilization Study indication rule; subgroups with and without cervical collar immobilization (CCI +/-) were compared with a control group (n = 20) of non-traumatized patients. Two independent readers evaluated retrospectively the alignment, determined the absolute rotational angle of the posterior surface of C2 and C7 (ARA C2-7) and grouped the results for lordosis (-1…

AdultMalemedicine.medical_specialtyEmergency Medical Servicesanimal structuresLordosisAdolescentKyphosisSpinal Curvatures030218 nuclear medicine & medical imaging03 medical and health sciencesYoung Adult0302 clinical medicineTrauma CentersMultidetector Computed TomographyEmergency Radiology special featuremedicineHumansRadiology Nuclear Medicine and imagingKyphosisYoung adultRetrospective StudiesObserver Variationbusiness.industryRetrospective cohort studyGeneral MedicineMiddle Agedmedicine.diseaseCervical spineSpinenervous system diseasesmedicine.anatomical_structureSpinal CurvaturesSpinal InjuriesCervical VertebraeLordosisCervical collarFemaleRadiologybusinesspsychological phenomena and processes030217 neurology & neurosurgeryCervical vertebraeThe British journal of radiology
researchProduct

Effect of Kernels Used for the Reconstruction of MDCT Datasets on the Semi-Automated Segmentation and Volumetry of Liver Lesions

2014

Purpose: To evaluate the effect of different reconstruction kernels on the semi-automated segmentation of liver lesions in MDCT. Materials and Methods: A total 62 liver lesions were measured by three independent radiologists with the semi-automated segmentation software Oncology-Prototype (Fraunhofer MEVIS, Siemens Healthcare, Germany) using MDCT datasets (3-mm slice thickness, 2-mm increment) reconstructed with standard, soft and detailed kernels (Philips B, A and D). To ensure objective measurements, only lesions with satisfactory initial segmentation were included, and manual correction was not used. The effective diameter and volume were recorded for each lesion. Segmentation in the sof…

AdultMalemedicine.medical_specialtyLung NeoplasmsInitial SeedAutomated segmentationBreast NeoplasmsTumor responseSensitivity and SpecificityMultidetector Computed TomographyImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingSegmentationTumor growthAgedMathematicsAged 80 and overbusiness.industryLiver NeoplasmsPattern recognitionSpiral Cone-Beam Computed TomographyGold standard (test)Middle AgedTumor BurdenEffective diameterLiverKernel (statistics)FemaleArtificial intelligenceRadiologyColorectal NeoplasmsbusinessSoftwareRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Imaging findings of hepatic focal nodular hyperplasia in men and women: are they really different?

2014

Purpose This study was undertaken to compare the imaging findings of focal nodular hyperplasia (FNH) in men and women, as seen on multidetector computed tomography (MDCT), magnetic resonance imaging (MRI) and contrast-enhanced ultrasound (CEUS). Materials and methods Two radiologists reviewed 195 imaging studies (17 MDCT, 81 MRI and 97 CEUS examinations) pertaining to 111 FNHs (mean size 3 cm) in 91 patients (mean age 39 years). For each lesion, the readers assessed size, location, echogenicity, attenuation, or signal intensity in comparison with adjacent liver parenchyma on both unenhanced and postcontrast images. Results Eighty-nine FNHs (mean size 3.1 cm) were observed in 73 women (mean …

AdultMalemedicine.medical_specialtySulfur HexafluorideContrast MediaSettore MED/01 - Statistica MedicaMeglumineSex FactorsSex factorsMultidetector computed tomographyMultidetector Computed TomographyOrganometallic CompoundsMedicineHumansRadiology Nuclear Medicine and imagingcardiovascular diseasesPhospholipidsNeuroradiologyAgedmedicine.diagnostic_testbusiness.industryUltrasoundFocal nodular hyperplasiaMagnetic resonance imagingInterventional radiologyGeneral MedicineMiddle Agedmedicine.diseaseMagnetic Resonance ImagingFocal nodular hyperplasia liver Computed tomographyMagnetic resonance imagingContrast-enhanced ultrasoundIopamidolFocal Nodular Hyperplasiacardiovascular systemFemaleRadiologybusinessSettore MED/36 - Diagnostica Per Immagini E RadioterapiaContrast-enhanced ultrasound
researchProduct

Forty-slice MDCT enteroclysis: evaluation after oral administration of isotonic solution in Crohn's disease.

2007

Objective. The aim of this study was to evaluate the accuracy of multidetector computed tomography (MDCT) enteroclysis after oral hyperhydration with isotonic solution in detecting bowel wall alterations in patients with Crohn’s disease. Materials and methods. Twenty-eight patients with a diagnosis of Crohn’s disease established by ileocolonoscopy and histology were enrolled in the study; 15 patients with negative ileocolonoscopy served as controls. In all cases, MDCT enteroclysis was performed after oral administration of 2,000 ml of isotonic solution and intravenous administration of N-butylscopolamine. Axial, isotropic multiplanar and volume-rendered reconstructions were used to evaluate…

AdultMalemedicine.medical_specialtymedicine.medical_treatmentAdministration OralContrast MediaIntestino tenueSensitivity and SpecificityPolyethylene GlycolsCrohn DiseaseOral administrationPatologie gastrointestinaliIntestine SmallMedicineIntubationHumansRadiology Nuclear Medicine and imagingNeuroradiologyTC multidetettoreCrohn's diseasemedicine.diagnostic_testbusiness.industryCatharticsMultidetector CTUltrasoundInterventional radiologyGeneral MedicineEnemamedicine.diseaseGastrointestinal diseaseSmall boweldigestive system diseasesSpiral computed tomographyIopamidolFemaleRadiologyIsotonic SolutionsbusinessTomography X-Ray ComputedLa Radiologia medica
researchProduct

A robust aerial image registration method using Gaussian mixture models

2014

Aerial image registration is one of the bases in many aerospace applications, such as aerial reconnaissance and aerial mapping. In this paper, we propose a novel aerial image registration algorithm which is based on Gaussian mixture models. First of all, considering the characters of the aerial images, the work uses a shape feature detector which computes the boundaries of regions with nearly the same gray-value to extract invariant feature. Then, a Gaussian mixture models (GMM) based image registration model is built and solved to estimate the transformation matrix between two aerial images. Furthermore, the proposed method is applied on real aerial images, and the results demonstrate the …

Aerial surveyComputer sciencebusiness.industryFeature detectorCognitive NeuroscienceComputingMethodologies_IMAGEPROCESSINGANDCOMPUTERVISIONImage registrationComputerApplications_COMPUTERSINOTHERSYSTEMSPattern recognitionComputer Science Applications1707 Computer Vision and Pattern RecognitionMixture modelAerial images; Feature detector; Gaussian mixture models; Image registration; Computer Science Applications1707 Computer Vision and Pattern Recognition; Cognitive Neuroscience; Artificial IntelligenceComputer Science ApplicationsComputer Science::RoboticsComputer Science::Systems and ControlArtificial IntelligenceComputer Science::Computer Vision and Pattern RecognitionAerial imagesComputer visionAerial reconnaissanceArtificial intelligenceGaussian mixture modelsbusinessAerial imageImage registration
researchProduct

Comparison of UV and charged aerosol detection approach in pharmaceutical analysis of statins

2009

Abstract CAD (charged aerosol detector) has recently become a new alternative detection system in HPLC. This detection approach was applied in a new HPLC method for the determination of three of the major statins used in clinical treatment—simvastatin, lovastatin and atorvastatin. The method was optimized and the influence of individual parameters on CAD response and sensitivity was carefully studied. Chromatography was performed on a Zorbax Eclipse XDB C18 (4.6 mm × 75 mm, 3.5 μm), using acetonitrile and formic acid 0.1% as mobile phase. The detection was performed using both CAD (20 pA range) and DAD (diode array detector—238 nm) simultaneously connected in series. In terms of linearity, …

AerosolsSimvastatinAccuracy and precisionChromatographyChemistryFormic acidDetectorAnalytical chemistryLinearityCADHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundEquipment and SuppliesHeptanoic AcidsWide dynamic rangeAtorvastatinPyrrolesLovastatinHydroxymethylglutaryl-CoA Reductase InhibitorsQuantitative analysis (chemistry)Chromatography High Pressure LiquidTabletsTalanta
researchProduct

Application of time-of-flight aerosol mass spectrometry for the online measurement of gaseous molecular iodine.

2012

Here we present a new application of a time-of-flight aerosol mass spectrometer (TOF-AMS) for the measurement of atmospheric trace gases in real-time. Usually, TOF-AMS instruments are not sensitive to gas-phase species due to the aerodynamic particle focusing inlet system which reduces the gas phase species by a factor of about 10(7) relative to the particle phase. This efficient removal of the gas phase and the resulting high relative enrichment of particles is one reason for the very high sensitivity of TOF-AMS instruments for particle phase compounds (detection limits in the sub-μg/m(3)-range for online measurements with 1 min integration time), which allows application of the instrument…

Aerosolsalpha-CyclodextrinsPhysics::Instrumentation and DetectorsChemistryAnalytical chemistryIodidesMass spectrometryPhaeophytaGas Chromatography-Mass SpectrometryAnalytical ChemistryTrace gasAerosolTime of flightOzonePhase (matter)ParticleAerosol mass spectrometryGasesGas chromatography–mass spectrometryAnalytical chemistry
researchProduct