Digital fast pulse shape and height analysis on cadmium-zinc-telluride arrays for high-flux energy-resolved X-ray imaging.
2017
Cadmium-zinc-telluride (CZT) arrays with photon-counting and energy-resolving capabilities are widely proposed for next-generation X-ray imaging systems. This work presents the performance of a 2â...mm-thick CZT pixel detector, with pixel pitches of 500 and 250â...μm, dc coupled to a fast and low-noise ASIC (PIXIE ASIC), characterized only by the preamplifier stage. A custom 16-channel digital readout electronics was used, able to digitize and process continuously the signals from each output ASIC channel. The digital system performs on-line fast pulse shape and height analysis, with a low dead-time and reasonable energy resolution at both low and high fluxes. The spectroscopic response …
Dual-polarity pulse processing and analysis for charge-loss correction in cadmium–zinc–telluride pixel detectors
2018
Charge losses at the inter-pixel gap are typical drawbacks in cadmium–zinc–telluride (CZT) pixel detectors. In this work, an original technique able to correct charge losses occurring after the application of charge-sharing addition (CSA) is presented. The method, exploiting the strong relation between the energy after CSA and the beam position at the inter-pixel gap, allows the recovery of charge losses and improvements in energy resolution. Sub-millimetre CZT pixel detectors were investigated with both uncollimated radiation sources and collimated synchrotron X-rays, at energies below and above the K-shell absorption energy of the CZT material. The detectors are DC coupled to fast and low…
Sterols in infant formulas: validation of a gas chromatographic method.
2017
AbstractSterols are components present in the fat fraction of infant formulas (IFs). Their characterization is therefore of interest, though there are no official reference methods for their analysis in these matrices.Aim: To validate a gas chromatographic method with flame ionization detection for the determination of animal (cholesterol and desmosterol) and plant sterols (brassicasterol, campesterol, stigmasterol, β-sitosterol and sitostanol) found in IFs.All correlation coefficients obtained for the calibration curves of sterols studied were >0.99. Limits of detection (<1 μg/100 mL) and quantification (<4 μg/100 mL) are suitable for sterols determination in IFs. The within-assay precisio…
Improved electroless platinum contacts on CdZnTe X- and γ-rays detectors
2020
AbstractPlatinum is a promising candidate for the realization of blocking electrical contacts on cadmium-zinc-telluride (CdZnTe or CZT) radiation detectors. However, the poor mechanical adhesion of this metal often shortens the lifetime of the final device. In this work, a simple and effective procedure to obtain robust platinum contacts by electroless deposition is presented. Microscopical analysis revealed the final thickness and composition of the contact layer and its adhesion to the bulk crystal. The blocking nature of the Pt-CdZnTe junction, essential to obtain low noise devices, was confirmed by current–voltage measurements. The planar Pt-CdZnTe-Pt detectors showed good room temperat…
2017
Significant progress in nonlinear and ultrafast optics has recently opened new and exciting opportunities for terahertz (THz) science and technology, which require the development of reliable THz sources, detectors, and supporting devices. In this work, we demonstrate the first solid-state technique for the coherent detection of ultra-broadband THz pulses (0.1–10 THz), relying on the electric-field-induced second-harmonic generation in a thin layer of ultraviolet fused silica. The proposed CMOS-compatible devices, which can be realized with standard microfabrication techniques, allow us to perform ultra-broadband detection with a high dynamic range by employing probe laser powers and bias v…
Extricating New Physics Scenarios at DUNE with High Energy Beams
2017
The proposed Deep Underground Neutrino Experiment (DUNE) utilizes a wide-band on-axis tunable muon-(anti)neutrino beam with a baseline of 1300 km to search for CP violation with high precision. Given the long baseline, DUNE is also sensitive to effects due to non-standard neutrino interactions (NSI) which can interfere with the standard 3-flavor oscillation paradigm. In this Letter, we exploit the tunability of the DUNE neutrino beam over a wide-range of energies and utilize a new theoretical metric to devise an experimental strategy for separating oscillation effects due to NSI from the standard 3-flavor oscillation scenario. Using our metric, we obtain an optimal combination of beam tunes…
Imaging through scattering media by microstructured illumination
2016
We describe a method to image objects through scattering media based on microstructured illumination. A spatial light modulator is used to project a set of microstructured light patterns onto the sample. The image is retrieved computationally from the photocurrent fluctuations provided by a detector with no spatial structure. We review several optical setups developed in the last years with different illumination strategies and applied to different turbid media. In particular we introduce a new non-invasive optical system based on a reflection configuration. Our technique does not require coherent light, raster scanning, time-gated detection or a-priori calibration processes. Furthermore it…
Upgrades of the GANDALPH photodetachment detector towards the determination of the electron affinity of astatine
2020
The Gothenburg ANion Detector for Affinity measurements by Laser PHotodetachment (GANDALPH) has recently been built for measurements of electron affinities (EA) of radioisotopes. A first measurement campaign is aimed towards the determination of the EA of astatine, the rarest naturally occurring element on earth. In this work we present several upgrades of GANDALPH which have been implemented in order to facilitate EA measurements of radioisotopes where only low intensity ion beams (< 1pA) can be produced.
First measurement of the W-boson mass in run II of the Tevatron.
2007
7 pages, 4 figures.-- PACS nrs.: 14.70.Fm; 13.38.Be; 13.85.Qk.-- ISI Article Identifier: 000250140600014.-- ArXiv pre-print available at: http://arxiv.org/abs/0707.0085.-- et al.
Evidence for the production of three massive vector bosons with the ATLAS detector
2019
A search for the production of three massive vector bosons in proton–proton collisions is performed using data at TeV recorded with the ATLAS detector at the Large Hadron Collider in the years 2015–2017, corresponding to an integrated luminosity of 79.8 fb−1. Events with two same-sign leptons ℓ (electrons or muons) and at least two reconstructed jets are selected to search for . Events with three leptons without any same-flavour opposite-sign lepton pairs are used to search for , while events with three leptons and at least one same-flavour opposite-sign lepton pair and one or more reconstructed jets are used to search for . Finally, events with four leptons are analysed to search for and .…