Search results for "DIAGNOSTICA"
showing 10 items of 607 documents
Usefulness of SonoVue in the identification of sentinel nodes in patients with breast cancer
2013
Purpose Methods and Materials Results Conclusion References Personal Information
Neuroimaging delle Demenze
2012
Sin dai suoi esordi la diagnostica per immagini ha profondamente rivoluzionato la diagnostica neurologica. Tecniche quali la tomografia computerizzata (TC) e la risonanza magnetica (RM) si sono, nel corso degli anni, rivelate di enorme vantaggio per i pazienti affetti da patologie neurologiche. Tuttavia, quello delle malattie neurodegenerative con particolare riferimento alle demenze, tra i tanti capitoli delle neuroscienze, è quello che probabilmente ha meno usufruito dei vantaggi offerti dalla diagnostica neuroradiologica “convenzionale”. Sebbene negli ultimi due/tre lustri le apparecchiature TC ed RM abbiano infatti subito una forte spinta evolutiva complice l'irrefrenabile progresso te…
Spectrum of non-cardiac collateral findings in patients with suspected coronary artery disease assessed with Multislice Computed Tomography Coronary …
2009
Dosimetry for electron Intra-Operative RadioTherapy: Comparison of output factors obtained through alanine/EPR pellets, ionization chamber and Monte …
2015
Abstract In this work a comparison between the response of alanine and Markus ionization chamber was carried out for measurements of the output factors (OF) of electron beams produced by a linear accelerator used for Intra-Operative Radiation Therapy (IORT). Output factors (OF) for conventional high-energy electron beams are normally measured using ionization chamber according to international dosimetry protocols. However, the electron beams used in IORT have characteristics of dose per pulse, energy spectrum and angular distribution quite different from beams usually used in external radiotherapy, so the direct application of international dosimetry protocols may introduce additional uncer…
Correlation between ferrous ammonium sulfate concentration, sensitivity and stability of Fricke gel dosimeters exposed to clinical X-ray beams
2014
Abstract This work describes the characterization of various Fricke-Agarose-Xylenol gels (FXG) dosimeters using NMR relaxometry and MRI analysis. Using X-rays from a clinical linear accelerator (LINAC), the gels were irradiated in the dose range from 0 Gy to 20 Gy. The photon sensitivity of the FXGs was measured in terms of NMR relaxation rates; its dependence on radiation dose was determined as a function of ferrous ammonium sulfate contents (from 0.5 mM to 5 mM). Furthermore, the stability of the NMR signal was monitored over several days after irradiation. These measurements were aided by Magnetic Resonance Imaging (MRI) scans which allowed three-dimensional (3D) dose mapping. In order t…
Analysis of spatial diffusion of ferric ions in PVA-GTA gel dosimeters through magnetic resonance imaging
2017
Abstract This work focused on the analysis of the temporal diffusion of ferric ions through PVA-GTA gel dosimeters. PVA-GTA gel samples, partly exposed with 6 MV X-rays in order to create an initial steep gradient, were mapped using magnetic resonance imaging on a 7T MRI scanner for small animals. Multiple images of the gels were acquired over several hours after irradiation and were analyzed to quantitatively extract the signal profile. The spatial resolution achieved is 200 μm and this makes this technique particularly suitable for the analysis of steep gradients of ferric ion concentration. The results obtained with PVA-GTA gels were compared with those achieved with agarose gels, which …
Analysis of the response of PVA-GTA Fricke-gel dosimeters with clinical magnetic resonance imaging
2018
Abstract Fricke gel dosimeters produced with a matrix of Poly-vinyl alcohol (PVA) cross-linked with glutaraldehyde (GTA) were analyzed with magnetic resonance imaging (MRI). Previous studies based on spectrophotometry showed valuable dosimetric features of these gels in terms of X-ray sensitivity and diffusion of the ferric ions produced after irradiation. In this study, MRI was performed on the gels at 1.5 T with a clinical scanner in order to optimize the acquisition parameters and obtain high contrast between irradiated and non-irradiated samples. The PVA gels were found to offer good linearity in the range of 0–10 Gy and a stable signal for several hours after irradiation. The sensitivi…
Clinical outcome of recurrent locally advanced cervical cancer (LACC) submitted to primary multimodality therapies
2015
Abstract Objectives Recurrence of disease represents a clinical challenge in cervical cancer patients, especially when all available treatment modalities have been used in the primary setting. The aim of this study was to analyze the patterns of recurrence and their association with clinical outcome in locally advanced cervical cancer (LACC) patients submitted to primary chemoradiation (CTRT) followed by radical surgery (RS). Methods This study was conducted on 364 LACC patients treated with CTRT plus RS since January 1996 to July 2012. For each relapse, information on date of clinical/pathological recurrence, and pattern of disease presentation were retrieved. Post-relapse survival (PRS) w…
Nomograms for predicting local recurrence, distant metastases, and overall survival for patients with locally advanced rectal cancer on the basis of …
2011
Purpose The purpose of this study was to develop accurate models and nomograms to predict local recurrence, distant metastases, and survival for patients with locally advanced rectal cancer treated with long-course chemoradiotherapy (CRT) followed by surgery and to allow for a selection of patients who may benefit most from postoperative adjuvant chemotherapy and close follow-up. Patients and Methods All data (N = 2,795) from five major European clinical trials for rectal cancer were pooled and used to perform an extensive survival analysis and to develop multivariate nomograms based on Cox regression. Data from one trial was used as an external validation set. The variables used in the ana…
Expanding the Liver Imaging Reporting and Data System (LI-RADS) v2018 diagnostic population: performance and reliability of LI-RADS for distinguishin…
2018
Abstract Background Hepatocellular carcinoma (HCC) can be diagnosed using imaging criteria in patients at high-risk for HCC, according to Liver Imaging Reporting and Data System (LI-RADS) guidelines. The aim of this study was to determine the diagnostic performance and inter-rater reliability (IRR) of LI-RADS v2018 for differentiating HCC from non-HCC primary liver carcinoma (PLC), in patients who are at increased risk for HCC but not included in the LI-RADS ‘high-risk’ population. Methods This retrospective HIPAA-compliant study included a 10-year experience of pathologically-proven PLC at two liver transplant centers, and included patients with non-cirrhotic hepatitis C infection, non-cir…