Search results for "DICS"
showing 10 items of 2714 documents
The “Journal of Functional Morphology and Kinesiology” Journal Club Series: Highlights of Recent Papers in Pediatric Exercise
2019
We are glad to introduce the ninth Journal Club. This edition is focused on several relevant studies published in the last years in the field of Pediatric Exercise, chosen by our Editorial Board members and their colleagues. We hope to stimulate your curiosity in this field and to share with you the passion for the sport as seen also from the scientific point of view. The Editorial Board members wish you an inspiring lecture.
Force normalization in paraplegics.
2012
The principal aim of our study was the determination of the effectiveness of a standardized ratio, allometric scaling model and a gamma function model in normalizing the isometric torque data of spinal cord patients and healthy subjects. For this purpose we studied a sample of 21 healthy males and 23 spinal cord injury males. The experiment consisted of the measurement of the force of the upper limb movement executed by all the subjects. We also determined anthropometric variables with dual-energy x-ray absorptiometry. The experimental data were analyzed with 3 force normalization methods. Our results indicate that the most important confounding variable was the fat free mass of the dominan…
Determining the optimal maximal and submaximal voluntary contraction tests for normalizing the erector spinae muscles
2019
Background This study aimed to identify which maximum voluntary isometric contraction (MVIC) and sub-MVIC tests produce the highest activation of the erector spinae muscles and the greatest reduction in inter-individual variability, to put them forward as reference normalization maneuvers for future studies. Methods Erector spinae EMG activity was recorded in 38 healthy women during five submaximal and three maximal exercises. Results None of the three MVIC tests generated the maximal activation level in all the participants. The maximal activation level was achieved in 68.4% of cases with the test performed on the roman chair in the horizontal position (96.3 ± 7.3; p < 0.01). Of the fi…
Fabrication of a negative PMMA master mold for soft-lithography by MeV ion beam lithography
2012
Abstract In this study, poly(methyl methacrylate) (PMMA) was investigated as a negative resist by irradiation with a high-fluence 2 MeV proton beam. The beam from a 1.7 MV Tandetron accelerator at the Plasma and Beam Physics Research Facility (PBP) of Chiang Mai University is shaped by a pair of computer-controlled L-shaped apertures which are used to expose rectangular pattern elements with 1–1000 μm side length. Repeated exposure of rectangular pattern elements allows a complex pattern to be built up. After subsequent development, the negative PMMA microstructure was used as a master mold for casting poly(dimethylsiloxane) (PDMS) following a standard soft-lithography process. The PDMS chi…
Development of elastomeric lab-on-a-chip devices through Proton Beam Writing (PBW) based fabrication strategies
2009
Abstract In recent years, one of the most exciting developments in fluidic device applications is the rapid evolution of miniaturized micro- and nanofluidic systems, the so called “lab-on-a-chip” devices. These devices integrate laboratory functions into a single chip, and are capable of various biochemical analysis and synthesis, such as sample injection and preparation, single cell/molecule observation, bioparticle sequencing and sorting etc. The evolvement of lab-on-a-chip concept implies the use of novel fabrication techniques for the construction of versatile analytical components in a fast and reproducible manner. Endowed with unique three-dimensional fabrication abilities, Proton Bea…
Development of procedures for programmable proximity aperture lithography
2013
Abstract Programmable proximity aperture lithography (PPAL) with MeV ions has been used in Jyvaskyla and Chiang Mai universities for a number of years. Here we describe a number of innovations and procedures that have been incorporated into the LabView-based software. The basic operation involves the coordination of the beam blanker and five motor-actuated translators with high accuracy, close to the minimum step size with proper anti-collision algorithms. By using special approaches, such writing calibration patterns, linearisation of position and careful backlash correction the absolute accuracy of the aperture size and position, can be improved beyond the standard afforded by the repeata…
Estimation of errors in mechanical efficiency
1990
Errors in measurements of mechanical work, net energy expenditure and mechanical efficiency (ME) were calculated, when subjects performed isolated eccentric or concentric muscle actions and combinations of these actions [stretch-shortening cycle (SSC) exercises] with a special sledge apparatus. The relative error of mechanical work was 6.1%. When estimating the error of energy metabolism from oxygen consumption the error would be about 4% (McArdle et al. 1981). The maximum error of ME was the sum of these two values (10.1%). Obviously the error of ME was less than 5%, because 30 muscle actions were averaged and, in addition, the errors of mechanical work and energy expenditure were not in t…
Neuromuscular Adaptations after Blood Flow Restriction Training Combined with Nutritional Supplementation: A Preliminary Study
2019
Blood fl ow restriction training (BFRT) has been shown to be an eff ective alternative technique to conventional resistance training to increase skeletal muscle hypertrophy and strength. However, neuromuscular response to BFRT in combination with nutritional supplementation has rarely been studied. Th e purpose of this study was to investigate the eff ects of BFRT combined with creatine monohydrate (CrM) and/or hydroxymethyl butyrate (HMB) on skeletal muscle size and strength. Fift een healthy males were randomly divided into three groups: a) BFRT without supplementation (C-BFR); b) BFRT with CrM supplementation (0.3 g / kg-1) (CrM-BFR); and c) BFRT with CrM (0.3 g / kg-1) and HMB (3 g) sup…
Validity of long-term and short-term recall of occupational sitting time in Finnish and Chinese office workers.
2020
Abstract Background As sedentary behavior is a global health issue, there is a need for methods of self-reported sitting assessment. The accuracy and reliability of these methods should also be tested in various populations and different cultural contexts. This study examined the validity of long-term and short-term recall of occupational sitting time in Finnish and Chinese subgroups. Methods Two cohort groups of office-based workers (58.6% female, age range 22–67 years) participated: a Finnish group (FIN, n = 34) and a Chinese group (CHI, n = 36). Long-term (past 3-month sitting) and short-term (daily sitting assessed on 5 consecutive days) single-item measures were used to assess self-r…