Search results for "DICS"

showing 10 items of 2714 documents

The “Journal of Functional Morphology and Kinesiology” Journal Club Series: Highlights of Recent Papers in Pediatric Exercise

2019

We are glad to introduce the ninth Journal Club. This edition is focused on several relevant studies published in the last years in the field of Pediatric Exercise, chosen by our Editorial Board members and their colleagues. We hope to stimulate your curiosity in this field and to share with you the passion for the sport as seen also from the scientific point of view. The Editorial Board members wish you an inspiring lecture.

Ninthlcsh:Diseases of the musculoskeletal systemHistologymedia_common.quotation_subjectPhysical Therapy Sports Therapy and RehabilitationPassionEditorial board030204 cardiovascular system & hematology03 medical and health sciences0302 clinical medicineRheumatologyFunctional morphologyOrthopedics and Sports Medicinemedia_commonJournal club health promotion fitness sportMedical educationKinesiology030229 sport sciencesEditorialn/aCuriositylcsh:RC925-935AnatomyJournal clubPsychologySettore M-EDF/01 - Metodi E Didattiche Delle Attivita' MotorieJournal of Functional Morphology and Kinesiology
researchProduct

Force normalization in paraplegics.

2012

The principal aim of our study was the determination of the effectiveness of a standardized ratio, allometric scaling model and a gamma function model in normalizing the isometric torque data of spinal cord patients and healthy subjects. For this purpose we studied a sample of 21 healthy males and 23 spinal cord injury males. The experiment consisted of the measurement of the force of the upper limb movement executed by all the subjects. We also determined anthropometric variables with dual-energy x-ray absorptiometry. The experimental data were analyzed with 3 force normalization methods. Our results indicate that the most important confounding variable was the fat free mass of the dominan…

Normalization (statistics)AdultMaleIsometric torquePhysical Therapy Sports Therapy and RehabilitationModels BiologicalUpper ExtremityAbsorptiometry PhotonmedicineBody SizeHumansOrthopedics and Sports MedicineMuscle StrengthMuscle SkeletalSpinal cord injurySpinal Cord InjuriesOrthodonticsParaplegiaAnthropometrybusiness.industryConfoundingHealthy subjectsAnthropometrymedicine.diseaseSpinal cordmedicine.anatomical_structureTorqueBody CompositionUpper limbbusinessInternational journal of sports medicine
researchProduct

Determining the optimal maximal and submaximal voluntary contraction tests for normalizing the erector spinae muscles

2019

Background This study aimed to identify which maximum voluntary isometric contraction (MVIC) and sub-MVIC tests produce the highest activation of the erector spinae muscles and the greatest reduction in inter-individual variability, to put them forward as reference normalization maneuvers for future studies. Methods Erector spinae EMG activity was recorded in 38 healthy women during five submaximal and three maximal exercises. Results None of the three MVIC tests generated the maximal activation level in all the participants. The maximal activation level was achieved in 68.4% of cases with the test performed on the roman chair in the horizontal position (96.3 ± 7.3; p < 0.01). Of the fi…

Normalization (statistics)medicine.medical_specialtyAnatomy and Physiologylcsh:MedicineElectromyographyIsometric exerciseGeneral Biochemistry Genetics and Molecular BiologyErector spinae03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationVoluntary contractionRoman chairErector spinae musclesmedicineColumna vertebral - Músculos - Electromiografía.Maximum voluntary isometric contractionmedicine.diagnostic_testbusiness.industryElectromyographyGeneral Neurosciencelcsh:R030229 sport sciencesGeneral MedicineSpine - Muscles - Electromyography.KinesiologyTrunkSub-maximum voluntary isometric contractionNormalizationOrthopedicsElectromyography.Horizontal position representationGeneral Agricultural and Biological SciencesbusinessElectromiografía.030217 neurology & neurosurgery
researchProduct

Fabrication of a negative PMMA master mold for soft-lithography by MeV ion beam lithography

2012

Abstract In this study, poly(methyl methacrylate) (PMMA) was investigated as a negative resist by irradiation with a high-fluence 2 MeV proton beam. The beam from a 1.7 MV Tandetron accelerator at the Plasma and Beam Physics Research Facility (PBP) of Chiang Mai University is shaped by a pair of computer-controlled L-shaped apertures which are used to expose rectangular pattern elements with 1–1000 μm side length. Repeated exposure of rectangular pattern elements allows a complex pattern to be built up. After subsequent development, the negative PMMA microstructure was used as a master mold for casting poly(dimethylsiloxane) (PDMS) following a standard soft-lithography process. The PDMS chi…

Nuclear and High Energy PhysicsFabricationMaterials scienceta114business.industryMicrofluidicsNanotechnologyPhotoresistIon beam lithographyCastingSoft lithographyOptoelectronicsIrradiationbusinessInstrumentationBeam (structure)Nuclear Instruments and Methods in Physics Research B
researchProduct

Development of elastomeric lab-on-a-chip devices through Proton Beam Writing (PBW) based fabrication strategies

2009

Abstract In recent years, one of the most exciting developments in fluidic device applications is the rapid evolution of miniaturized micro- and nanofluidic systems, the so called “lab-on-a-chip” devices. These devices integrate laboratory functions into a single chip, and are capable of various biochemical analysis and synthesis, such as sample injection and preparation, single cell/molecule observation, bioparticle sequencing and sorting etc. The evolvement of lab-on-a-chip concept implies the use of novel fabrication techniques for the construction of versatile analytical components in a fast and reproducible manner. Endowed with unique three-dimensional fabrication abilities, Proton Bea…

Nuclear and High Energy PhysicsMaterials scienceFabricationNanotechnologyengineering.materialLab-on-a-chipProton beam writingSoft lithographylaw.inventionCharacterization (materials science)CoatinglawengineeringNanometreFluidicsInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Development of procedures for programmable proximity aperture lithography

2013

Abstract Programmable proximity aperture lithography (PPAL) with MeV ions has been used in Jyvaskyla and Chiang Mai universities for a number of years. Here we describe a number of innovations and procedures that have been incorporated into the LabView-based software. The basic operation involves the coordination of the beam blanker and five motor-actuated translators with high accuracy, close to the minimum step size with proper anti-collision algorithms. By using special approaches, such writing calibration patterns, linearisation of position and careful backlash correction the absolute accuracy of the aperture size and position, can be improved beyond the standard afforded by the repeata…

Nuclear and High Energy Physicsta114business.industryApertureComputer sciencemicrofluidicsScalable Vector GraphicsFaraday cupcomputer.file_formatMeV ion beam lithographyprogrammable proximity aperture lithography (PPAL)symbols.namesakeSoftwareOpticsion-fluencePosition (vector)CalibrationElectronic engineeringsymbolsbusinessInstrumentationLithographycomputerBeam (structure)Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Estimation of errors in mechanical efficiency

1990

Errors in measurements of mechanical work, net energy expenditure and mechanical efficiency (ME) were calculated, when subjects performed isolated eccentric or concentric muscle actions and combinations of these actions [stretch-shortening cycle (SSC) exercises] with a special sledge apparatus. The relative error of mechanical work was 6.1%. When estimating the error of energy metabolism from oxygen consumption the error would be about 4% (McArdle et al. 1981). The maximum error of ME was the sum of these two values (10.1%). Obviously the error of ME was less than 5%, because 30 muscle actions were averaged and, in addition, the errors of mechanical work and energy expenditure were not in t…

Observational errorPhysiologyMusclesPublic Health Environmental and Occupational HealthBiomechanicsEfficiencyGeneral MedicineFunction (mathematics)ConcentricModels BiologicalStretch shortening cycleBiomechanical PhenomenaMechanical systemControl theoryApproximation errorPhysiology (medical)HumansEccentricOrthopedics and Sports MedicineEnergy MetabolismExerciseMathematicsMathematicsEuropean Journal of Applied Physiology and Occupational Physiology
researchProduct

Neuromuscular Adaptations after Blood Flow Restriction Training Combined with Nutritional Supplementation: A Preliminary Study

2019

Blood fl ow restriction training (BFRT) has been shown to be an eff ective alternative technique to conventional resistance training to increase skeletal muscle hypertrophy and strength. However, neuromuscular response to BFRT in combination with nutritional supplementation has rarely been studied. Th e purpose of this study was to investigate the eff ects of BFRT combined with creatine monohydrate (CrM) and/or hydroxymethyl butyrate (HMB) on skeletal muscle size and strength. Fift een healthy males were randomly divided into three groups: a) BFRT without supplementation (C-BFR); b) BFRT with CrM supplementation (0.3 g / kg-1) (CrM-BFR); and c) BFRT with CrM (0.3 g / kg-1) and HMB (3 g) sup…

Occlusion trainingNutritional SupplementationFisioteràpiabusiness.industryocclusion trainingMuscle strengthRehabilitationSkeletal muscle hypertrophyPhysiologyPhysical Therapy Sports Therapy and RehabilitationBlood flow restrictionSkeletal muscle hypertrophyGV557-1198.995Sports medicineMuscle strengthmuscle strengthEducación Física y DeportivaMedicineOrthopedics and Sports MedicinebusinessRC1200-1245Sports
researchProduct

Validity of long-term and short-term recall of occupational sitting time in Finnish and Chinese office workers.

2020

Abstract Background As sedentary behavior is a global health issue, there is a need for methods of self-reported sitting assessment. The accuracy and reliability of these methods should also be tested in various populations and different cultural contexts. This study examined the validity of long-term and short-term recall of occupational sitting time in Finnish and Chinese subgroups. Methods Two cohort groups of office-based workers (58.6% female, age range 22–67 years) participated: a Finnish group (FIN, n  = 34) and a Chinese group (CHI, n  = 36). Long-term (past 3-month sitting) and short-term (daily sitting assessed on 5 consecutive days) single-item measures were used to assess self-r…

Occupational sittingAdultMalemedicine.medical_specialtyChinaTime FactorsDaily recallPhysical Therapy Sports Therapy and RehabilitationSittingSitting timeOffice workersValidity03 medical and health scienceslcsh:GV557-1198.995Young Adult0302 clinical medicineAccelerometryMedicineHumansOrthopedics and Sports Medicine030212 general & internal medicinelcsh:Sports medicineWorkplaceFinlandAgedlcsh:SportsSitting PositionRecallbusiness.industryQuestionnaireReproducibility of Results030229 sport sciencesMiddle AgedSitting timeConfidence intervalTerm (time)Regular paperCohortMental RecallPhysical therapyFemaleSelf ReportSedentary BehaviorOffice workersbusinesslcsh:RC1200-1245Self-reportJournal of sport and health science
researchProduct

Digital acrometastasis revealing endometrial cancer relapse

2012

Oncology030222 orthopedicsmedicine.medical_specialtybusiness.industryEndometrial cancerImmunologymedicine.disease03 medical and health sciences0302 clinical medicineRheumatology030220 oncology & carcinogenesisInternal medicinemedicineImmunology and AllergyPharmacology (medical)businessArthritis & Rheumatism
researchProduct