Search results for "DICS"
showing 10 items of 2714 documents
A Locked Intraosseous Nail for Transverse Patellar Fractures: A Biomechanical Comparison with Tension Band Wiring Through Cannulated Screws.
2018
Background Displaced transverse patellar fractures require open reduction and internal fixation. State-of-the-art stabilization techniques are tension band wiring (TBW) using Kirschner wires or cannulated screws. These techniques are associated with high rates of secondary fracture displacement, implant migration, implant prominence, wound-healing disturbances, and the need for implant removal. Recently, a locked intraosseous patellar nail prototype was developed. The aim of the present study was to investigate the biomechanical performance of this nail compared with TBW using cannulated screws. Methods Seven paired fresh-frozen human cadaveric knees were stripped of all soft tissues except…
Leg and joint stiffness in human hopping
2010
The present study investigated the regulation of leg and joint stiffness in hopping at different intensity levels. Eight male subjects performed bilateral hopping at various intensity levels that were determined by peak vertical ground reaction force (GRF). In addition to the GRF, the measurements included hopping kinematics and electromyography (EMG) of selected leg muscles. While the leg and ankle joint stiffness remained invariant, the knee joint stiffness increased significantly (P<0.01) with the hopping intensity. EMG analysis revealed a significant increase in averaged EMG for all the measured muscles before and during the early phase of ground contact (P<0.05-0.001) with increasing h…
Influence of the Screw Positioning on the Stability of Locking Plate for Proximal Tibial Fractures: A Numerical Approach
2020
Tibial fractures are common injuries in people. The proper treatment of these fractures is important in order to recover complete mobility. The aim of this work was to investigate if screw positioning in plates for proximal tibial fractures can affect the stability of the system, and if it can consequently influence the patient healing time. In fact, a more stable construct could allow the reduction of the non-weight-bearing period and consequently speed up the healing process. For that purpose, virtual models of fractured bone/plate assemblies were created, and numerical simulations were performed to evaluate the reaction forces and the maximum value of the contact pressure at the screw/bo…
Traction test of temporary dental cements
2017
Background Classic self-curing temporary cements obstruct the translucence of provisional restorations. New dual-cure esthetic temporary cements need investigation and comparison with classic cements to ensure that they are equally retentive and provide adequate translucence. The objective is to analyze by means of traction testing in a in vitro study the retention of five temporary cements. Material and methods Ten molars were prepared and ten provisional resin restorations were fabricated using CAD-CAM technology (n=10). Five temporary cements were selected: self-curing temporary cements, Dycal (D), Temp Bond (TB), Temp Bond Non Eugenol (TBNE); dual-curing esthetic cements Temp Bond Clear…
Effects of muscle activation on shear between human soleus and gastrocnemius muscles
2015
Lateral connections between muscles provide pathways for myofascial force transmission. To elucidate whether these pathways have functional roles in vivo, we examined whether activation could alter the shear between the soleus (SOL) and lateral gastrocnemius (LG) muscles. We hypothesized that selective activation of LG would decrease the stretch-induced shear between LG and SOL. Eleven volunteers underwent a series of knee joint manipulations where plantar flexion force, LG, and SOL muscle fascicle lengths and relative displacement of aponeuroses between the muscles were obtained. Data during a passive full range of motion were recorded, followed by 20° knee extension stretches in both pass…
MRI findings and physical performance as predictors of flight-induced musculoskeletal pain incidence among fighter pilots
2017
Summary Study aim: The aim of this study was to evaluate the possible association of pre-career magnetic resonance imaging (MRI) findings and physical performance level with possible musculoskeletal disorders during jet flight training. Material and methods: The study group consisted of 73 fighter pilots who had undergone pre-career cervical and lumbar spine MRI. Physical performance of a subgroup of the pilots (n = 67) was measured initially at the same time and followed up to the fast jet training phase (ranging from 3.8 to 7.0 years). Musculoskeletal pain history during pilot training was taken from the medical charts. MRI findings and physical performance were associated with perceived…
Dynamic Gait Parameters in Patients With Nonunion of the Tibia Following Treatment With the Ilizarov Method.
2020
Abstract The purpose of this study was a comprehensive assessment of the dynamic parameters of gait in patients who underwent Ilizarov treatment for nonunion of the tibia. The experimental group consisted of 24 individuals treated with the Ilizarov method for nonunion of the tibia. The control group comprised 31 healthy individuals, matched for BMI, sex, and age. The dynamic gait parameters in patients and in the control group were measured with a Zebris pedobarographic platform. The treatment group and the control group showed statistically significant differences in terms of the following gait parameters: maximum force during braking nonoperated-limb (NOL), time maximum force during braki…
MRI evaluation to predict tendon size for knee ligament reconstruction.
2017
Background The aim of this study is to evaluate a possible correlation between specific anthropometric parameters and sizes of knee tendons commonly used for ACL reconstruction. We hypothesized that specific clinical and radiological knee measurements could be better tendon sizes predictors than age, gender, height and weight. Materials and methods 100 consecutive patients were enrolled and 77 patients met the inclusion criteria of the study. All patients underwent a MRI of the knee with a 1.5 T super conducting MR System. For each patient, anthropometric data such as gender, height, weight, body mass index (BMI) and knee circumference were recorded. Specific MRI knee measurements were perf…
Posterior stability in posterior-stabilized vs medially congruent total knee replacement: A radiological comparison of two polyethylene designs in a …
2020
Objective:The purpose of this radiological study was to assess the posterior laxity of a single model of a total knee arthroplasty design (TKA) having a medially constrained (MC) or a Posterior-Stabilized (PS) polyethylene insert using a well-documented stress x-ray. To the authors knowledge, this is the first report evaluating MC TKA outcomes according to the “kneeling view.”Materials and Methods:Sixty patients with non-traumatic primary knee osteoarthritis undergoing TKA were first matched by age, sex, BMI and diagnosis and then divided in two groups: group A (37 knees) received a MC TKA and group B (23 knees) a PS implant made by the same manufacturer. In all cases the posterior cruciate…
2019
Ultrasound tissue characterization (UTC) imaging has been previously used to describe the characteristics of patellar and Achilles tendons. UTC imaging compares and correlates successive ultrasonographic transverse tendon images to calculate the distribution of four color-coded echo-types that represent different tendon tissue types. However, UTC has not been used to describe the characteristics of patellar tendons after anterior cruciate ligament reconstruction (ACLR). The aim of this cross-sectional study was to assess the intra and inter-rater reliability of the UTC in unharvested and harvested patellar tendons of patients undergoing ACLR. Intra and inter-rater reliability of both UTC da…