Search results for "DOPPLER"

showing 10 items of 637 documents

Which is the best ultrasound parameter for the prediction of adverse perinatal outcome within 1 day of delivery?

2021

To compare the accuracies of several sonographic parameters for the prediction of adverse perinatal outcome (APO) prior to delivery.This was a prospective study of fetuses attending the day hospital unit of a tertiary referral hospital that were scanned at 34-41 weeks and gave birth within 24 h of examination. APO was defined as a composite of abnormal intrapartum fetal heart rate or intrapartum fetal scalp pH7.20 requiring urgent cesarean section, neonatal umbilical cord pH7.10, 5' Apgar score7 and postpartum admission to neonatal or pediatric intensive care units. The accuracies of the middle cerebral, vertebral and umbilical arteries pulsatility index multiples of the median (MoM), the c…

medicine.medical_specialtyMiddle Cerebral ArteryPerinatal outcomemacromolecular substancesUltrasonography PrenatalUmbilical ArteriesPregnancyPredictive Value of Testsmedicine.arterymedicineHumansProspective StudiesProspective cohort studyChildFetusbusiness.industryObstetricsCesarean SectionUltrasoundInfant NewbornPregnancy OutcomeObstetrics and GynecologyFetal dopplerUltrasonography DopplerPulsatile FlowPediatrics Perinatology and Child HealthMiddle cerebral arteryFemalebusinessThe journal of maternal-fetalneonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians
researchProduct

Birth-weight differences at term are explained by placental dysfunction and not by maternal ethnicity. Study in newborns of first generation immigran…

2020

The aim of the study was to investigate the influence of ethnicity and cerebroplacental ratio (CPR) on the birth weight (BW) of first generation Indo-Pakistan immigrants' newborns.This was a retrospective study in a mixed population of 620 term Caucasian and Indo-Pakistan pregnancies, evaluated in two reference hospitals of Spain and Italy. All fetuses underwent a scan and Doppler examination within two weeks of delivery. The influence of fetal gender, ethnicity, GA at delivery, CPR, maternal age, height, weight and parity on BW was evaluated by multivariable regression analysis.Newborns of first generation Indo-Pakistan immigrants were smaller than local Caucasian newborns (mean BW mean= 3…

medicine.medical_specialtyMiddle Cerebral Arterymedia_common.quotation_subjectBirth weightPlacentaImmigrationEthnic groupEmigrants and ImmigrantsGestational AgeUltrasonography PrenatalUmbilical ArteriesPlacental dysfunctionPregnancymedicineEthnicityBirth WeightHumanshealth care economics and organizationsmedia_commonRetrospective StudiesObstetricsbusiness.industryInfant NewbornParturitionObstetrics and GynecologyFetal dopplerFirst generationTerm (time)Pediatrics Perinatology and Child Healthpopulation characteristicsFemaleFetal nutritionbusinessgeographic locationsThe journal of maternal-fetalneonatal medicine : the official journal of the European Association of Perinatal Medicine, the Federation of Asia and Oceania Perinatal Societies, the International Society of Perinatal Obstetricians
researchProduct

Therapeutic decision-making for patients with fluctuating mitral regurgitation

2015

Mitral regurgitation (MR) is a common, progressive, and difficult-to-manage disease. MR is dynamic in nature, with physiological fluctuations occurring in response to various stimuli such as exercise and ischaemia, which can precipitate the development of symptoms and subsequent cardiac events. In both chronic primary and secondary MR, the dynamic behaviour of MR can be reliably examined during stress echocardiography. Dynamic fluctuation of MR can also have prognostic value; patients with a marked increase in regurgitant volume or who exhibit increased systolic pulmonary artery pressure during exercise have lower symptom-free survival than those who do not experience significant changes in…

medicine.medical_specialtyMitral Valve Annuloplastymedicine.medical_treatmentClinical Decision-MakingCardiac resynchronization therapyDoppler echocardiographyRevascularizationCardiac Resynchronization TherapyEchocardiography StreMitral valve annuloplastyInternal medicinemedicine.arteryMitral valveStress EchocardiographyHumansMedicineCardiac Resynchronization Therapy; Clinical Decision-Making; Echocardiography Doppler; Echocardiography Stress; Exercise; Humans; Mitral Valve; Mitral Valve Annuloplasty; Mitral Valve Insufficiency; Cardiology and Cardiovascular Medicine; Medicine (all)ExerciseMitral regurgitationmedicine.diagnostic_testbusiness.industryMedicine (all)Mitral Valve InsufficiencyEchocardiography Dopplermedicine.anatomical_structurePulmonary arteryCardiologyMitral ValveRadiologyCardiology and Cardiovascular MedicinebusinessHumanEchocardiography StressNature Reviews Cardiology
researchProduct

Objective measures of nasal function

1995

Numerous techniques to objectively measure nasal function are available to the rhinologic surgeon. Rhinomanometry, acoustic rhinometry, laser Doppler flowmetry, saccharin transport time, determination of ciliary beat frequency, and olfactory and trigeminal event-related potentials are all techniques in current use. Rhinomanometry is the standard clinical tool used to indicate those patients complaining of nasal obstruction who are likely to benefit from septal and turbinate surgery. Acoustic rhinometry permits the precise localization of nasal stenoses and is the best predictor of a patient's postoperative satisfaction. It is, in addition, more sensitive than rhinomanometry in recording cha…

medicine.medical_specialtyMucosal swellingmedicine.diagnostic_testbusiness.industryTransport timeBlood flowLaser Doppler velocimetryAcoustic rhinometryOtorhinolaryngologyOlfactory nerveOphthalmologyotorhinolaryngologic diseasesMedicineSurgeryRhinomanometrybusinessAirwayCurrent Opinion in Otolaryngology & Head and Neck Surgery
researchProduct

Echocardiographic assessment of coronary microvascular dysfunction: Basic concepts, technical aspects, and clinical settings

2021

Abstract Coronary flow reserve is the capacity of the coronary circulation to augment the blood flow in response an increase in myocardial metabolic demands and has a powerful prognostic significance in different clinical situations. It might assess with invasive and noninvasive technique. Transthoracic echocardiography Doppler is an emerging diagnostic technique, noninvasive, highly feasible, safe for patient and physician, without radiation, and able to detect macrovascular and microvascular anomalies in the coronary circulation. This review aims to describe the benefit and limits of echocardiographic assessment of coronary flow reserve.

medicine.medical_specialtyMyocardial ischemiacoronary flow reservecoronary physiologyMyocardial IschemiaReviewsClinical settingsReview030204 cardiovascular system & hematologyDoppler echocardiographycoronary flow reserve; coronary microvascular dysfunction; coronary physiology; Doppler echocardiography; microcirculation; Blood Flow Velocity; Coronary Circulation; Echocardiography; Echocardiography Doppler; Humans; Microcirculation; Coronary Vessels; Myocardial IschemiaMicrocirculation03 medical and health sciencesCoronary circulation0302 clinical medicineCoronary CirculationInternal medicineHumansMedicineRadiology Nuclear Medicine and imaging030212 general & internal medicineCoronary Vesselcoronary microvascular dysfunctionmedicine.diagnostic_testbusiness.industryMicrocirculationDopplerCoronary flow reserveBlood flowCoronary VesselsDoppler echocardiographyEchocardiography Dopplermedicine.anatomical_structureEchocardiographyCardiologyCardiology and Cardiovascular MedicinebusinessCoronary physiologyBlood Flow VelocityHumanEchocardiography
researchProduct

Role of cardiac dyssynchrony and resynchronization therapy in functional mitral regurgitation

2016

Functional mitral regurgitation (FMR) is a common complication of left ventricle (LV) dysfunction and remodelling. Recently, it has been recognized as an independent prognostic factor in both ischaemic and non-ischaemic LV dysfunctions. In this review article, we discuss the mechanisms through which cardiac dyssynchrony is involved in FMR pathophysiologic cascade and how cardiac resynchronization therapy (CRT) can have therapeutic effects on FMR by reverting specific dyssynchrony pathways. We analyse recent clinical trials focusing on CRT impact on FMR in 'real-world' patients, the limits and future perspectives that could eventually generate new predictors of CRT response in terms of FMR r…

medicine.medical_specialtyPacemaker Artificialmedicine.medical_treatmentCardiac resynchronization therapyVentricular dyssynchrony030204 cardiovascular system & hematologyCardiac resynchronization; Mitral regurgitation; Ventricular dyssynchrony; Cardiology and Cardiovascular Medicine; Radiology Nuclear Medicine and ImagingVentricular Function LeftCardiac Resynchronization Therapy03 medical and health sciencesVentricular Dysfunction Left0302 clinical medicineInternal medicineCardiac resynchronizationNuclear Medicine and ImagingmedicineHumansRadiology Nuclear Medicine and imaging030212 general & internal medicineVentricular remodelingVentricular dyssynchronyMitral regurgitationMitral regurgitationClinical Trials as TopicVentricular Remodelingbusiness.industryCardiac Pacing ArtificialMitral Valve InsufficiencyStroke VolumeGeneral MedicineStroke volumemedicine.diseasePrognosisReview articleEchocardiography Doppler ColorClinical trialmedicine.anatomical_structureTreatment OutcomeVentriclecardiovascular systemCardiologyRadiologybusinessCardiology and Cardiovascular MedicineRadiology
researchProduct

PaO2oscillations caused by cyclic alveolar recruitment can be monitored in pig buccal mucosa microcirculation

2012

BACKGROUND Cyclic alveolar recruitment and derecruitment play a role in the pathomechanism of acute lung injury and may lead to arterial partial pressure of oxygen (PaO(2) ) oscillations within the respiratory cycle. It remains unknown, however, if these PaO(2) oscillations are transmitted to the microcirculation. The present study investigates if PaO(2) oscillations can be detected in the pig buccal mucosa microcirculation. METHODS Respiratory failure was induced by surfactant depletion in seven pigs. PaO(2) oscillations caused by cyclic recruitment and derecruitment were measured in the thoracic aorta by fast fluorescence quenching of oxygen technology. Haemoglobin oxygen saturation, haem…

medicine.medical_specialtyPathologyRespiratory ratebusiness.industrychemistry.chemical_elementGeneral MedicineBlood flowLung injuryLaser Doppler velocimetryOxygenMicrocirculationAnesthesiology and Pain MedicineRespiratory failurechemistryInternal medicineCardiologyMedicinebusinessOxygen saturation (medicine)Acta Anaesthesiologica Scandinavica
researchProduct

Ticlopidine in the Treatment of Multiple Atherosclerotic Arteriopathy: a Strain Gauge Plethysmography and Döppler Spectrum Analysis Evaluation

1987

The effect of ticlopidine was compared with flunarizine in patients with iliac–femoral and / or femoral–popliteal arteriosclerotic arteriopathy accompanied by lesions of the cervical arteries of no haemodynamic significance. In the lower limbs, plethysmography (strain gauge measurements) and Döppler ultrasonography integrated by spectral analysis of the cervical arteries showed qualitative and quantitative improvements of the regional haematic flow. Side-effects were negligible which suggests that ticlopidine is useful in the treatment of multiple arteriosclerotic arteriopathy.

medicine.medical_specialtyPathologyTiclopidineArteriosclerosisCervical ArteryHemodynamics030204 cardiovascular system & hematologyBiochemistry03 medical and health sciencessymbols.namesake0302 clinical medicineInternal medicineHumansMedicinePlethysmograph030212 general & internal medicineTiclopidineFlunarizineAgedUltrasonographybusiness.industryVascular diseaseBiochemistry (medical)Cell BiologyGeneral MedicineMiddle Agedmedicine.diseasePlethysmographyCardiologysymbolsbusinessDoppler effectBlood Flow VelocityFlunarizinemedicine.drugStrain gauge plethysmographyJournal of International Medical Research
researchProduct

Correlation of skeletal muscle blood oxygenation level-dependent MRI and skin laser doppler flowmetry in patients with systemic sclerosis

2013

Purpose To investigate the origin of skeletal muscle BOLD MRI alterations in patients with systemic sclerosis (SSc) by correlating BOLD MRI T2* signal of calf muscles with microcirculatory blood flow of calf skin measured by laser Doppler flowmetry (LDF). Materials and Methods BOLD MRI (3T) and LDF measurements were performed in 12 consecutive SSc patients (6 women, 6 men; mean age 54.0 ± 10.0 years) and 12 healthy volunteers (4 men, 8 women; mean age 44.7 ± 13.1 years). For both modalities, the same cuff compression paradigm at mid-thigh level was used. LDF datasets were acquired using a PeriScan PIM II Imager (Perimed AB, Stockholm, Sweden) at the upper calf corresponding to the level of …

medicine.medical_specialtyPathologyintegumentary systembusiness.industryBlood oxygenation level dependentSkeletal muscleBlood flowLaser Doppler velocimetryCorrelationmedicine.anatomical_structureInternal medicineCuffmedicineCardiologyRadiology Nuclear Medicine and imagingIn patientbusinessPerfusionJournal of Magnetic Resonance Imaging
researchProduct

On the Number of Measurements Necessary to Assess Regional Cerebral Blood Flow by Local Laser Doppler Recordings: A Simulation Study with Data from 4…

1995

Laser Doppler fluxmetry may improve the monitoring of cortical blood flow in neurosurgical patients. So far, however, the variability of laser Doppler readings found in the cerebral cortex has prevented a consequent usage of the technique in clinical practice. The current report analyzes the regional variability of laser Doppler readings from experimental animals. Typical frequency histograms of observed flow values display non-Gaussian distributions. A simulation technique is used to assess the number of measuring sites required for valid estimates of regional cortical flow. From a total of 990 local flow measurements from 45 rabbits random samples of sizes between 5 and 100 were repeatedl…

medicine.medical_specialtyPercentilePhysiologyReproducibility of ResultsBlood flowLaser Doppler velocimetryMicrocirculationSurgeryRandom AllocationCerebral blood flowFlow (mathematics)Evaluation Studies as TopicSample size determinationCerebrovascular CirculationLaser doppler fluxmetryLaser-Doppler FlowmetrymedicineAnimalsEnvironmental scienceComputer SimulationFemaleRabbitsCardiology and Cardiovascular MedicineBiomedical engineeringInternational Journal of Microcirculation
researchProduct