Search results for "DOSIMETRY"

showing 10 items of 297 documents

<title>Use of AlN ceramics in ultraviolet radiation dosimetry</title>

2003

AlN-Y2O3 ceramics is studied as a material for application in the area of ultraviolet radiation (UVR) dosimetry. The properties of optically stimulated luminescence (OSL) and thermally stimulated luminescence (TL) revealed by AlN ceramics are characterized and considered for practical application. A special attention is devoted to studies of the spectral properties of the material, including stimulated luminescence. Spectral properties of the material make it potentially suitable for dosimetric application both in UV-C region (200-290 nm), where it has the maximum sensitivity, and in UV-B+UV-A (290-350 nm) region, where the spectral behavior of its sensitivity coincides rather well with tha…

Materials scienceOptically stimulated luminescencebusiness.industryOptical engineeringSpectral propertiesvisual_artvisual_art.visual_art_mediumOptoelectronicsDosimetryCeramicbusinessLuminescenceSensitivity (electronics)Ultraviolet radiationSPIE Proceedings
researchProduct

RADICAL DISTRIBUTIONS IN AMMONIUM TARTRATE SINGLE CRYSTALS EXPOSED TO PHOTON AND NEUTRON BEAMS

2014

The radiation therapy carried out by means of heavy charged particles (such as carbon ions) and neutrons is rapidly becoming widespread worldwide. The success of these radiation therapies relies on the high density of energy released by these particles or by secondary particles produced after primary interaction with matter. The biological damages produced by ionising radiations in tissues and cells depend more properly on the energy released per unit pathlength, which is the linear energy transfer and which determines the radiation quality. To improve the therapy effectiveness, it is necessary to grasp the mechanisms of free radical production and distribution after irradiation with these …

Materials sciencePhotonFree RadicalsTrack nanodosimetryLinear energy transferElectronsRadiationMolecular physicsIonizing radiationMagneticsRadiation IonizingRadiology Nuclear Medicine and imagingHeavy IonsIrradiationCobalt RadioisotopesRadiometryTartratesNeutronsRange (particle radiation)PhotonsRadiationRadiological and Ultrasound TechnologyRadiation induced radicals ammonium tartrate pulsed electron paramagnetic resonanceelectron spin resonancePublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyGeneral MedicineCharged particleNeutron temperatureSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)CarbonGamma RaysTrack nanodosimetry; electron spin resonanceCrystallization
researchProduct

Study of the glow curves of TLD exposed to thermal neutrons.

2007

The glow curves of thermoluminescent dosimeters (TLD600, TLD700 and MCP), exposed to a mixed field of thermal neutrons and gamma photons are analysed. The fluence values of thermal neutrons used, comparable with those used in radiotherapy, allow one to define the reliability of the TLDs, in particular the most sensitive MCP, in this radiation field and to get information on the dose absorbed values. The glow curves obtained have been deconvoluted using general order kinetics and the observed differences for the different LET components have been analysed. In particular, the ratio of the n(0) parameter of two different peaks seems to allow to discriminate the different contributions of neutr…

Materials sciencePhotonHot TemperatureThermoluminescenceAstrophysics::High Energy Astrophysical PhenomenaPhysics::Medical PhysicsRadiation DosageThermoluminescenceFluenceSensitivity and SpecificityRadiation ProtectionDosimetryRadiology Nuclear Medicine and imagingNeutronComputer SimulationNeutron beamNeutronsRadiationDosimeterRadiological and Ultrasound Technologybusiness.industryPublic Health Environmental and Occupational HealthReproducibility of ResultsGeneral MedicineEquipment DesignModels TheoreticalSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Neutron temperatureEquipment Failure AnalysisComputer-Aided DesignThermoluminescent DosimetryThermoluminescent dosimeterAtomic physicsNuclear medicinebusinessBeam (structure)Radiation protection dosimetry
researchProduct

A monte carlo study of dose rate distribution around the specially asymmetric CSM3-a 137Cs source.

2001

The CSM3 137Cs type stainless-steel encapsulated source is widely used in manually afterloaded low dose rate brachytherapy. A specially asymmetric source, CSM3-a, has been designed by CIS Bio International (France) substituting the eyelet side seed with an inactive material in the CSM3 source. This modification has been done in order to allow a uniform dose level over the upper vaginal surface when this `linear' source is inserted at the top of the dome vaginal applicators. In this study the Monte Carlo GEANT3 simulation code, incorporating the source geometry in detail, was used to investigate the dosimetric characteristics of this special CSM3-a 137Cs brachytherapy source. The absolute do…

Materials scienceRadiological and Ultrasound Technologybusiness.industryRadioactive sourceRadiotherapy Planning Computer-AssistedMonte Carlo methodBrachytherapyDose levelSievert integralLow-Dose Rate BrachytherapyComputational physicsDistribution (mathematics)Cesium RadioisotopesNeoplasmsVaginaDosimetryHumansRadiology Nuclear Medicine and imagingFemaleDose rateNuclear medicinebusinessRadiometryMonte Carlo MethodAlgorithmsPhysics in medicine and biology
researchProduct

Depth-dose measurement corrections for the surface electronic brachytherapy beams of an Esteya® unit: a Monte Carlo study

2020

Abstract Three different correction factors for measurements with the parallel-plate ionization chamber PTW T34013 on the Esteya electronic brachytherapy unit have been investigated. This chamber type is recommended by AAPM TG-253 for depth-dose measurements in the 69.5 kV x-ray beam generated by the Esteya unit. Monte Carlo simulations using the PENELOPE-2018 system were performed to determine the absorbed dose deposited in water and in the chamber sensitive volume at different depths with a Type A uncertainty smaller than 0.1%. Chamber-to-chamber differences have been explored performing measurements using three different chambers. The range of conical applicators available, from 10 to 30…

Materials scienceRadiological and Ultrasound Technologymedicine.medical_treatmentMonte Carlo methodBrachytherapyConical surface030218 nuclear medicine & medical imagingComputational physics03 medical and health sciences0302 clinical medicine030220 oncology & carcinogenesisAbsorbed doseIonization chambermedicineDosimetryRadiology Nuclear Medicine and imagingDepth doseBeam (structure)Physics in Medicine & Biology
researchProduct

An EPR method for discriminating radiation beams in ammonium tartrate and tooth enamel

2008

The radiation linear energy transfer (LET), which is the energy released by ionizing radiation per path unit, arouses great scientific interest because the biological damage produced by ionizing radiation in tissues is strictly related to LET. Radiation beams with different LETs will cause different spatial energy distribution and therefore different effects inside matter. In the last twenty years the EPR spectroscopy has become a valuable dosimetric tool. This technique allows absorbed dose measurements through the detection of free radicals produced by ionizing radiation in organic and/or inorganic compounds. In this work we have analyzed the possibility of using the acquisition of two co…

Materials scienceRenewable Energy Sustainability and the EnvironmentHealth Toxicology and MutagenesisPublic Health Environmental and Occupational HealthLinear energy transferRadiationIonizing radiationlaw.inventionNuclear Energy and EngineeringlawAbsorbed doseDosimetryIrradiationAtomic physicsSafety Risk Reliability and QualityElectron paramagnetic resonanceAbsorption (electromagnetic radiation)Waste Management and DisposalRadioprotection
researchProduct

Neutron ESR dosimetry through ammonium tartrate with low Gd content.

2014

This paper continues analyses on organic compounds for application in neutron dosimetry performed through electron spin resonance (ESR). Here, the authors present the results obtained by ESR measurements of a blend of ammonium tartrate dosemeters and gadolinium oxide (5 % by weight). The choice of low amount of Gd is due to the need of improving neutron sensitivity while not significantly influencing tissue equivalence. A study of the effect of gadolinium presence on tissue equivalence was carried out. The experiments show that the neutron sensitivity is enhanced by more than an order of magnitude even with this small additive content. Monte Carlo simulations on the increment of energy rele…

Materials scienceSettore ING-IND/20 - Misure E Strumentazione NucleariGadoliniumMonte Carlo methodAnalytical chemistrychemistry.chemical_elementGadoliniumRadiationRadiation Dosagelaw.inventionlawDosimetryRadiology Nuclear Medicine and imagingNeutronElectron paramagnetic resonanceRadiometryTartratesNeutronsRadiationRadiological and Ultrasound Technologyammonium tartratebusiness.industryPublic Health Environmental and Occupational HealthElectron Spin Resonance SpectroscopyResonanceGeneral MedicineESR Dosimetryneutron dosimetrySettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)chemistryMeasuring instrumentNuclear medicinebusinessMonte Carlo MethodRadiation protection dosimetry
researchProduct

Study of encapsulated T170m sources for their potential use in brachytherapy

2010

Purpose: High dose-rate (HDR) brachytherapy is currently performed with {sup 192}Ir sources, and {sup 60}Co has returned recently into clinical use as a source for this kind of cancer treatment. Both radionuclides have mean photon energies high enough to require specific shielded treatment rooms. In recent years, {sup 169}Yb has been explored as an alternative for HDR-brachytherapy implants. Although it has mean photon energy lower than {sup 192}Ir, it still requires extensive shielding to deliver treatment. An alternative radionuclide for brachytherapy is {sup 170}Tm (Z=69) because it has three physical properties adequate for clinical practice: (a) 128.6 day half-life, (b) high specific a…

Materials sciencebusiness.industryCenter (category theory)Bremsstrahlungchemistry.chemical_elementGeneral MedicinePhoton energySpectral lineThuliumchemistryDosimetryEmission spectrumAtomic physicsCobalt-60Nuclear medicinebusinessMedical Physics
researchProduct

Confirmation of a realistic reactor model for BNCT dosimetry at the TRIGA Mainz

2014

Purpose: In order to build up a reliable dose monitoring system for boron neutron capture therapy (BNCT) applications at the TRIGA reactor in Mainz, a computer model for the entire reactor was established, simulating the radiation field by means of the Monte Carlo method. The impact of different source definition techniques was compared and the model was validated by experimental fluence and dose determinations. Methods: The depletion calculation code ORIGEN2 was used to compute the burn-up and relevant material composition of each burned fuel element from the day of first reactor operation to its current core. The material composition of the current core was used in a MCNP5 model of the in…

Materials sciencebusiness.industryNuclear engineeringMonte Carlo methodGeneral MedicineTRIGANeutron captureNuclear reactor coreCalibrationDosimetryNeutron sourceNeutronNuclear medicinebusinessMedical Physics
researchProduct

SU-E-T-691: Shielding Evaluation of a Treatment Room with An Electronic Brachytherapy System

2015

Purpose: Esteya™ (Elekta) is a brachytherapy electronic system used for treating skin cancer lesions. This unit is based on a 69.5 kV X-ray source and a surface applicator which produces a circular beam of a specific diameter, which varies from 1 to 3 cm. This study aims to establish the radiation protection measures for the system. Methods: A characterization of the scattered and leakage radiation of the system was implemented by means of experimental measurements. The scattered radiation measurements were performed with a Berthold LB133 ionization chamber, evaluating the dose rate for different distances from the applicator surface. The patient was simulated through water equivalent solid…

Materials sciencebusiness.industrymedicine.medical_treatmentBrachytherapyGeneral MedicineIonizing radiationLead shieldingAbsorbed doseIonization chamberElectromagnetic shieldingmedicineDosimetryRadiation protectionbusinessNuclear medicineMedical Physics
researchProduct