Search results for "DOSIMETRY"
showing 10 items of 297 documents
Brachytherapy treatment planning for complex applicators based on the AAPM TG-43 dosimetry algorithm: Case studies and clinical impact
2009
Spinal metastases: Is stereotactic body radiation therapy supported by evidences?
2016
Stereotactic body radiotherapy (SBRT) is becoming widely adopted in the treatment of primary and secondary tumors. Spinal bone metastases are frequently discovered in cancer patients, and in the past have been usually treated with a palliative goal. Nevertheless, in some particular clinical settings, such as oligometastatic patients and/or those with a long life expectancy, spinal SBRT could be considered a valid therapeutic option to obtain long-lasting palliation and, when possible, with a curative goal. This review aims to summarize available clinical and dosimetric data of published studies about spinal SBRT.
Dosimetric characterization of two radium sources for retrospective dosimetry studies
2015
Purpose: During the first part of the 20th century, Ra-226 was the most used radionuclide for brachytherapy. Retrospective accurate dosimetry, coupled with patient follow up, is important for advan ...
REVIEW OF RETROSPECTIVE DOSIMETRY TECHNIQUES FOR EXTERNAL IONISING RADIATION EXPOSURES
2011
The current focus on networking and mutual assistance in the management of radiation accidents or incidents has demonstrated the importance of a joined-up approach in physical and biological dosimetry. To this end, the European Radiation Dosimetry Working Group 10 on 'Retrospective Dosimetry' has been set up by individuals from a wide range of disciplines across Europe. Here, established and emerging dosimetry methods are reviewed, which can be used immediately and retrospectively following external ionising radiation exposure. Endpoints and assays include dicentrics, translocations, premature chromosome condensation, micronuclei, somatic mutations, gene expression, electron paramagnetic re…
Uncertainty on radiation doses estimated by biological and retrospective physical methods
2018
International audience; Biological and physical retrospective dosimetry are recognised as key techniques to provide individual estimates of dose following unplanned exposures to ionising radiation. Whilst there has been a relatively large amount of recent development in the biological and physical procedures, development of statistical analysis techniques has failed to keep pace. The aim of this paper is to review the current state of the art in uncertainty analysis techniques across the 'EURADOS Working Group 10- Retrospective dosimetry' members, to give concrete examples of implementation of the techniques recommended in the international standards, and to further promote the use of Monte…
Ionising radiation and lens opacities in interventional physicians: results of a German pilot study
2019
We assessed the feasibility of an epidemiological study on the risk of radiation-related lens opacities among interventional physicians in Germany. In a regional multi-centre pilot study associated with a European project, we tested the recruitment strategy, a European questionnaire on work history for the latter dosimetry calculation and the endpoint assessment. 263 interventional physicians and 129 non-exposed colleagues were invited. Questionnaires assessed eligibility criteria, risk factors for cataract, and work history relating to occupational exposure to ionising radiation, including details on type and amount of procedures performed, radiation sources, and use of protective equipmen…
EPR dosimetry intercomparison using smart phone touch screen glass
2014
International audience; This paper presents the results of an interlaboratory comparison of retrospective dosimetry using the electron paramagnetic resonance method. The test material used in this exercise was glass coming from the touch screens of smart phones that might be used as fortuitous dosimeters in a large-scale radiological incident. There were 13 participants to whom samples were dispatched, and 11 laboratories reported results. The participants received five calibration samples (0, 0.8, 2, 4, and 10 Gy) and four blindly irradiated samples (0, 0.9, 1.3, and 3.3 Gy). Participants were divided into two groups: for group A (formed by three participants), samples came from a homogene…
Therapeutic laser guidelines: On the effects of laser radiation on human skin-fibroblast metabolism in culture
1989
A promising field of laser utilization is the modification of cell behaviour. Acting on cell biological functions it might be possible to use them to improve medical therapies. This possibility suggests investigation of dosimetry guidelines employing different wavelenghts, power and exposure durations for future potential use of lasers in medicine.
2014
Background and purpose: A substantial reduction of uncertainties in clinical brachytherapy should result in improved outcome in terms of increased local control and reduced side effects. Types of uncertainties have to be identified, grouped, and quantified. Methods: A detailed literature review was performed to identify uncertainty components and their relative importance to the combined overall uncertainty. Results: Very few components (e.g., source strength and afterloader timer) are independent of clinical disease site and location of administered dose. While the influence of medium on dose calculation can be substantial for low energy sources or non-deeply seated implants, the influence…
SU-G-201-02: Application of RayStretch in Clinical Cases: A Calculation for Heterogeneity Corrections in LDR Permanent I-125 Prostate Brachytherapy
2016
Purpose: Tissue heterogeneities and calcifications have significant impact on the dosimetry of low energy brachytherapy (BT). RayStretch is an analytical algorithm developed in our institution to incorporate heterogeneity corrections in LDR prostate brachytherapy. The aim of this work is to study its application in clinical cases by comparing its predictions with the results obtained with TG-43 and Monte Carlo (MC) simulations. Methods: A clinical implant (71 I-125 seeds, 15 needles) from a real patient was considered. On this patient, different volumes with calcifications were considered. Its properties were evaluated in three ways by i) the Treatment planning system (TPS) (TG-43), ii) a M…