Search results for "DOT"

showing 10 items of 5147 documents

Granulometric moments and corneal endothelium status

2001

Abstract Specular microscopy is a common practice in Ophthalmology. The corneal endothelium status is usually evaluated by means of the density, the hexagonality, the mean, the standard deviation and the coefficient of variation of cell areas. We propose to replace the cell area moments by the corresponding moments of a different probability distribution, the granulometric size distribution associated to a disc. All cells touching the frame are ignored by the area moments but used by the granulometric moments. Twenty images have been analyzed. When the size of the focused region is reduced, the area moments show a greater variation than the corresponding granulometric moments.

Corneal endotheliumArtificial IntelligenceCoefficient of variationSignal ProcessingMathematical analysisSPECULAR MICROSCOPYStatisticsProbability distributionComputer Vision and Pattern RecognitionSoftwareStandard deviationShape analysis (digital geometry)MathematicsPattern Recognition
researchProduct

Granulometric analysis of corneal endothelium specular images by using a germ–grain model

2007

Specular microscopy is widely used to study the human corneal endothelium status in vivo. In this paper, the corneal endothelium is represented as a binary image composed of the cell inscribed circles. The granulometric distribution function of the complement of this image is used as a functional descriptor, which provides information about the shape, size and spatial arrangement of cells. Experimental evaluation using bootstrap techniques shows its ability to discriminate between controls and pathological cases. It represents a reliable and graphical alternative to the classical indices (cell density, hexagonality and coefficient of variation of cell areas), which behave poorly when detect…

Corneal endotheliumMaterials sciencegenetic structuresCell CountHealth InformaticsCell densityImage Processing Computer-AssistedHumansComputer SimulationComputer visionGermSpecular reflectionCell SizeMicroscopyFourier Analysisbusiness.industryBinary imageEndothelium CornealNumerical Analysis Computer-AssistedComputer Science ApplicationsOphthalmoscopySPECULAR MICROSCOPYArtificial intelligenceBiological systembusinessSoftwareShape analysis (digital geometry)Computers in Biology and Medicine
researchProduct

Corneal Oxygen Supply Conditions

1976

Pronounced cornea hypoxia induces swelling and a loss of transparency. Hypoxia of longer duration causes necrosis, particularly of the corneal endothelium. These findings were observed after ligation of the cilial arteries and the arteria carotis interna, after reduction of oxygen tension on the anterior corneal surface as well as after prolonged wearing of ill-fitted contact lenses (11, 15, 18, 22, 23). Because the normal function of the corneal endothelium plays a central role in maintaining transparency, an insufficient endothelial oxygen supply can directly influence vision (3, 17).

Corneal endotheliumOxygen supplymedicine.medical_specialtyNecrosisgenetic structuresbusiness.industryHypoxia (medical)eye diseasesOxygen tensionArteria carotis internamedicine.anatomical_structureCorneaOphthalmologyMedicinesense organsmedicine.symptomLigationbusiness
researchProduct

MORPHOMETRIC ANALYSIS OF HUMAN CORNEAL ENDOTHELIUM BY MEANS OF SPATIAL POINT PATTERNS

2002

This paper presents a method for detecting abnormalities in spatial arrangements of cells within any tissue that can be described by different sets of relevant points. The method has been applied to the detection of subtle abnormalities in corneal endothelia. Images of this type of tissue can be characterized by two types of points: cell centroids and triple points associated with the apical intersections as it was proposed by Díaz.7 Both types of points jointly considered are modeled using a bivariate spatial point process; then a statistical analysis based on certain distributional descriptors proposed by Doguwa4,9 is carried out to discriminate severe and subtle abnormalities from contr…

Corneal endotheliumbusiness.industryCentroidPattern recognitionBivariate analysisPoint processMorphometric analysisArtificial IntelligenceCell densityStatisticsPoint (geometry)Statistical analysisComputer Vision and Pattern RecognitionArtificial intelligencebusinessSoftwareMathematicsInternational Journal of Pattern Recognition and Artificial Intelligence
researchProduct

A granulometric analysis of specular microscopy images of human corneal endothelia

2005

The inner layer of the human cornea, called the corneal endothelium, plays an important role in the maintenance of corneal transparency. Specular microscopy is the most widely used technique to study the corneal endothelium in vivo. Improvements in technology have allowed us to obtain good quality specular images, but the detection and quantification of small size-shape cell changes is not obvious, specially when the physician wants to evaluate endothelial cell changes after some surgical procedures. This paper proposes a methodology to analyze specular microscopy images. Every corneal endothelium is described by means of different cumulative distribution functions or some moments (mean, st…

Corneal endotheliumgenetic structuresCoefficient of variationCumulative distribution functioneye diseasesStandard deviationmedicine.anatomical_structureSkewnessCorneaSignal ProcessingmedicineKurtosissense organsComputer Vision and Pattern RecognitionSoftwareShape analysis (digital geometry)MathematicsBiomedical engineeringComputer Vision and Image Understanding
researchProduct

Measuring the Spatial Homogeneity in Corneal Endotheliums by Means of a Randomization Test

1999

Quantification of regularity of cell sizes and the spatial arrangement of cells in corneal endotheliums becomes of a great importance associated to stress situations such as cataract surgery, corneal transplantation or implantation of intra-ocular lenses. A new index of regularity of the spatial distribution of cell sizes in corneal endotheliums is proposed. The corneal endothelium is described by means of a spatial marked point pattern (the cell centroids marked with the cell areas). The hypothesis of no dependency between mark and locations is tested by a Monte Carlo test. The new index is the p-value of the test validating the hypothesis. Pairs of endotheliums from different eyes of the …

Corneal endotheliumgenetic structuresCoefficient of variationmedicine.medical_treatmentCentroidSpatial distributioneye diseasesMonte carlo testResamplingStatisticsmedicinesense organsSpatial homogeneityCorneal transplantationMathematics
researchProduct

Classifying human endothelial cells based on individual granulometric size distributions

2002

Abstract This paper presents an application to a medical problem of methods of shape analysis based on mathematical morphology. The medical problem consists on the detection of abnormalities in the corneal endothelium, a tissue composed by quasi-planar cells of ideally regular hexagonal shape. Images of this tissue are taken by a specular microscope and used to evaluate the corneal endothelium status. Up to now, cell density, hexagonality and an analysis of cell areas are the usual descriptors of a corneal endothelium. These parameters are not sensitive enough to detect subtle lesions. What this paper proposes is an analysis based on granulometries, which are size-shape descriptors widely u…

Corneal endotheliumgenetic structuresComputer scienceHexagonal crystal systemSignal ProcessingCell densitySPECULAR MICROSCOPYCell analysisComputer Vision and Pattern RecognitionMathematical morphologyBiological systemShape analysis (digital geometry)Image and Vision Computing
researchProduct

Set Descriptors for Visual Evaluation of Human Corneal Endothelia

2001

Images of corneal endothelium obtained from specular microscopy are of great importance in the evaluation of the corneal endothelium status. Several commercial tools provide some numerical descriptors to characterize these images in terms of cell density, hexagonality, and some descriptive statistics of the cell areas. However, it is a too simple analysis that only detects severe abnormal endothelia with many irregular and large cells. Detection of subtle abnormalities needs a more refined analysis. This paper proposes a shape-size descriptor based on some modified versions of the geometric covariogram. This descriptor is presented as a valid alternative to the classical analysis that provi…

Corneal endotheliumgenetic structuresbusiness.industryComputer scienceSet (abstract data type)Signal ProcessingNumerical descriptorsCell densitySPECULAR MICROSCOPYcardiovascular systemComputer visionComputer Vision and Pattern RecognitionArtificial intelligencebusinessSoftwareComputer Vision and Image Understanding
researchProduct

Contributi firmati al volume "Alla ricerca di un ordine nuovo: Napoli e Palermo fra antico regime, rivoluzione e restaturazione (1759-1821)" tomo II,

2011

Costituzione siciliana del 1812 Antico RegimeSettore SPS/02 - Storia Delle Dottrine Politiche
researchProduct

Le Fonti del Diritto Italiano - Codice di Procedura Penale a cura di Giovanni Tranchina

2008

Costituzione codice di procedura penale norme di attuazione di coordinamento e transitorie leggi complementari dottrina e giurisprudenzaSettore IUS/16 - Diritto Processuale Penale
researchProduct