Search results for "Data acquisition"
showing 10 items of 237 documents
Methodological Aspects of Infrared Thermography in Human Assessment
2016
Infrared thermography presents some important advantages in the determination of skin temperature, as it is a safe, non-invasive and non-contact technique with wide applications in the field of sports sciences. Like many others techniques, valid measurement in thermography requires following strict methodological steps from data acquisition to analyses and interpretation. In this chapter, we discuss the methodological aspects that must be taken into account when acquiring thermic images, along with some practical examples and recommendations based on the current literature.
Tunable-frequency three-dimensional structured illumination microscopy with reduced data-acquisition
2018
The performance of a tunable three-dimensional (3D) structured illumination microscope (SIM) system and its ability to provide simultaneously super-resolution (SR) and optical-sectioning (OS) capabilities are investigated. Numerical results show that the performance of our 3D-SIM system is comparable with the one provided by a three-wave interference SIM, while requiring 40% fewer images for the reconstruction and providing frequency tunability in a cost-effective implementation. The performance of the system has been validated experimentally with images from test samples, which were also imaged with a commercial SIM based on incoherent-grid projection for comparison. Restored images from d…
The marine activities performed within the TOMO-ETNA experiment
2016
<p>The TOMO-ETNA experiment was planned in order to obtain a detailed geological and structural model of the continental and oceanic crust beneath Mt. Etna volcano and northeastern Sicily up to the Aeolian Islands (southern Italy), by integrating data from active and passive refraction and reflection seismic methodologies, magnetic and gravity surveys. This paper focuses on the marine activities performed within the experiment, which have been carried out in the Ionian and Tyrrhenian Seas, during three multidisciplinary oceanographic cruises, involving three research vessels (“Sarmiento de Gamboa”, “Galatea” and “Aegaeo”) belonging to different countries and institutions. During the o…
Monitoring of system conditioning after blank injections in untargeted UPLC-MS metabolomic analysis
2019
AbstractUltra-performance liquid chromatography – mass spectrometry (UPLC-MS) is widely used for untargeted metabolomics in biomedical research. To optimize the quality and precision of UPLC-MS metabolomic analysis, evaluation of blank samples for the elimination of background features is required. Although blanks are usually run either at the beginning or at the end of a sequence of samples, a systematic analysis of their effect of the instrument performance has not been properly documented. Using the analysis of two common bio-fluids (plasma and urine), we describe how the injection of blank samples within a sequence of samples may affect both the chromatographic and MS detection performa…
Exploiting Low-Cost 3D Imagery for the Purposes of Detecting and Analyzing Pavement Distresses
2020
Road pavement conditions have significant impacts on safety, travel times, costs, and environmental effects. It is the responsibility of road agencies to ensure these conditions are kept in an acceptable state. To this end, agencies are tasked with implementing pavement management systems (PMSs) which effectively allocate resources towards maintenance and rehabilitation. These systems, however, require accurate data. Currently, most agencies rely on manual distress surveys and as a result, there is significant research into quick and low-cost pavement distress identification methods. Recent proposals have included the use of structure-from-motion techniques based on datasets from unmanned a…
The IceCube data acquisition system: Signal capture, digitization, and timestamping
2008
IceCube is a km-scale neutrino observatory under construction at the South Pole with sensors both in the deep ice (InIce) and on the surface (IceTop). The sensors, called Digital Optical Modules (DOMs), detect, digitize and timestamp the signals from optical Cherenkov-radiation photons. The DOM Main Board (MB) data acquisition subsystem is connected to the central DAQ in the IceCube Laboratory (ICL) by a single twisted copper wire-pair and transmits packetized data on demand. Time calibration is maintained throughout the array by regular transmission to the DOMs of precisely timed analog signals, synchronized to a central GPS-disciplined clock. The design goals and consequent features, func…
Optical noninvasive monitoring of skin blood pulsations
2005
Time-resolved detection and analysis of skin backscattered optical signals (remission photoplethysmography or PPG) provide rich information on skin blood volume pulsations and can serve for reliable cardiovascular assessment. Single- and multiple-channel PPG concepts are discussed. Simultaneous data flow from several locations on the human body allows us to study heartbeat pulse-wave propagation in real time and to evaluate vascular resistance. Portable single-, dual-, and four-channel PPG monitoring devices with special software have been designed for real-time data acquisition and processing. The prototype devices have been clinically studied, and their potential for monitoring heart arrh…
Development of a test station for accurate in situ I-V curve measurements of photovoltaic modules in Southern Norway
2011
The development of an outdoor test station for accurate in situ I-V curve measurements of photovoltaic (PV) modules is described. The modules are installed in an open-rack configuration at the University of Agder in Southern Norway. Seven new and three aged PV modules of different type and make are being tested, including mono-and multicrystalline silicon from differing manufacturing routes, triple-junction amorphous silicon, and CIS. Data acquisition is controlled with a multichannel electronic load system and LabVIEW software, recording high-resolution I-V curves at one-minute intervals. Between I-V curve sweeps, each module is operated at the maximum power point. Characteristic electrica…
The IceCube prototype string in Amanda
2006
The Antarctic Muon And Neutrino Detector Array (Amanda) is a high-energy neutrino telescope. It is a lattice of optical modules (OM) installed in the clear ice below the South Pole Station. Each OM contains a photomultiplier tube (PMT) that detects photons of Cherenkov light generated in the ice by muons and electrons. IceCube is a cubic-kilometer-sized expansion of Amanda currently being built at the South Pole. In IceCube the PMT signals are digitized already in the optical modules and transmitted to the surface. A prototype string of 41 OMs equipped with this new all-digital technology was deployed in the Amanda array in the year 2000. In this paper we describe the technology and demonst…
Panel Discussion on Trends in Optical and Radio Data Analysis
1985
Albrecht: What I want to do is to give a brief five-minute introduction to the subject, justifying the title which puts optical and radio astronomy in one and the same category, which I believe it is, as far as data analysis is concerned, and then I will ask the panel members to give us two-minute statements of their opinions on the subject and then I would like to ask the audience to fire questions at us.