Safety and efficacy of implantable defibrillator therapy with programmed shock energy at twice the augmented step-down defibrillation threshold: resu…

1999

Whether the safety and efficacy of implantable cardioverter defibrillator (ICD) therapy can be assured with lower output devices is an important question. The purpose of this study was to evaluate whether programming the device output at twice the augmented defibrillation threshold was as safe and effective as using the maximum energy. Patients indicated for ICD therapy, but without slow monomorphic ventricular tachycardia (MVT), who achieved an augmented defibrillation threshold (DFT plus)or = 15 joules (J) with a single endocardial lead system and a biphasic defibrillator were included in the study. Prior to ICD implantation, patients were randomized into 2 groups. The shock energies in t…

AdultMalemedicine.medical_specialtyDefibrillationTest groupmedicine.medical_treatmentImplantable defibrillatorDefibrillation thresholdElectrocardiographyLow energyInternal medicineMedicineHumansProspective StudiesAgedEjection fractionEquipment Safetybusiness.industryMiddle AgedImplantable cardioverter-defibrillatorDefibrillators ImplantableSurvival RateTreatment OutcomeShock (circulatory)Ventricular FibrillationCardiologyTachycardia VentricularFemalemedicine.symptomCardiology and Cardiovascular MedicinebusinessSoftwareThe American journal of cardiology
researchProduct

Optimal Response to Cardiac Arrest study: Defibrillation waveform effects

2001

Abstract Introduction: Advances in early defibrillation access, key to the “Chain of Survival”, will depend on innovations in defibrillation waveforms, because of their impact on device size and weight. This study compared standard monophasic waveform automatic external defibrillators (AEDs) to an innovative biphasic waveform AED. Material and methods: Impedance-compensated biphasic truncated exponential (ICBTE) and either monophasic truncated exponential (MTE) or monophasic damped sine (MDS) AEDs were prospectively, randomly assigned by date in four emergency medical services. The study design compared ICBTE with MTE and MDS combined. This subset analysis distinguishes between the two clas…

AdultMalemedicine.medical_specialtyTime FactorsEndpoint DeterminationDefibrillationmedicine.medical_treatmentElectric CountershockEmergency NursingReturn of spontaneous circulationhemic and lymphatic diseasesInternal medicineIntensive careHumansMedicineChain of survivalCardiopulmonary resuscitationAutomated external defibrillatorAgedAged 80 and overbusiness.industryEquipment DesignMiddle Agedmedicine.diseaseSurvival AnalysisCardiopulmonary ResuscitationDefibrillators ImplantableHeart ArrestSurgeryEuropeTreatment OutcomeShock (circulatory)Ventricular fibrillationEmergency MedicineCardiologyFemalemedicine.symptomCardiology and Cardiovascular MedicinebusinessResuscitation
researchProduct

Effektivit�t pr�klinischer Notfallversorgung Fiktion oder Fakt?

1996

The current increase in the cost of health care must be considered as a severe threat to the prehospital emergency services system. Two examples have been selected--the patient with polytrauma and the patient in cardiac arrest--to demonstrate the dilemma between a need for objective data and the requirements of emergency patients. Study results obtained in trauma patients indicating that total prehospital time, including scene time, is correlated to patient outcome have led to the conclusion that at the scene treatment by emergency physicians may be dispensable. It has, however also been demonstrated that the time required for medical treatment at the scene is equivalent to 20% of the total…

Artificial ventilationmedicine.medical_specialtyEmergency managementbusiness.industryDefibrillationmedicine.medical_treatmentMEDLINEGeneral Medicinemedicine.diseasePolytraumaAnesthesiology and Pain MedicineVentricular fibrillationHealth caremedicineCardiopulmonary resuscitationIntensive care medicinebusinessDer Anaesthesist
researchProduct

“Three-level shock” in ablation-refractory paroxysmal atrial fibrillation

1987

His-bundle ablation is a very effective method to control drug-refractory supraventricular arrhythmias. We present a 69-year-old woman with paroxysmal atrial fibrillation, in whom several attempts of unipolar and bipolar His-bundle ablation were ineffective. Ultimately a stable 2/1 atrioventricular block was induced when three successive shocks of 400 W were applied. The first shock was given in that position with the largest His-potential deflection. The other two shocks were applied at catheter positions more distal and more proximal from the first one, respectively. We suppose that the initial lack of success was due to an atypical atrioventricular junction anatomy.

Bundle of HisCardiac Catheterizationmedicine.medical_specialtyDefibrillationParoxysmal atrial fibrillationmedicine.medical_treatmentElectric CountershockElectrocardiographyInternal medicineAtrial Fibrillationmental disordersmedicineHumanscardiovascular diseasesAgedSupraventricular arrhythmiabusiness.industryAtrial fibrillationGeneral Medicinemedicine.diseaseAblationCatheterHeart Blockcardiovascular systemCardiologyFemaleSupraventricular tachycardiaCardiology and Cardiovascular MedicinebusinessAtrioventricular blockClinical Cardiology
researchProduct

Fibrilación ventricular con parada cardiorrespiratoria durante la administración de dexmedetomidina

2015

Defibrillationbusiness.industrymedicine.medical_treatmentAdvanced cardiac life supportMEDLINEElectric countershockCritical Care and Intensive Care MedicineDrug SubstitutionAnesthesiology and Pain MedicineAnesthesiamedicineDexmedetomidinebusinessPropofolmedicine.drugRevista Española de Anestesiología y Reanimación
researchProduct

Protocol of a multicenter international randomized controlled manikin study on different protocols of cardiopulmonary resuscitation for laypeople (MA…

2018

IntroductionOut-of-hospital cardiac arrest is one of the leading causes of death in industrialised countries. Survival depends on prompt identification of cardiac arrest and on the quality and timing of cardiopulmonary resuscitation (CPR) and defibrillation. For laypeople, there has been a growing interest on hands-only CPR, meaning continuous chest compression without interruption to perform ventilations. It has been demonstrated that intentional interruptions in hands-only CPR can increase its quality. The aim of this randomised trial is to compare three CPR protocols performed with different intentional interruptions with hands-only CPR.Methods and analysisThis is a prospective randomise…

Defibrillationmedicine.medical_treatmenteducation030204 cardiovascular system & hematologyManikinscardiopulmonary resuscitationcardiopulmonary resuscitation; feedback devices; training; Medicine (all)03 medical and health sciencesContinuous chest compression0302 clinical medicineInformed consentProtocolmedicineHumans1506Prospective StudiesCardiopulmonary resuscitationTrial registrationRandomized Controlled Trials as TopicProtocol (science)trainingbusiness.industryMedicine (all)Ethics committeeBasic life support030208 emergency & critical care medicineGeneral Medicinemedicine.disease1691feedback deviceItalyfeedback devicesEmergency MedicineMedical emergencybusinessOut-of-Hospital Cardiac Arrest
researchProduct

European Clinical Experience with a Dual Chamber Single Pass Sensing and Pacing Defibrillation Lead

2002

Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of…

MaleBradycardiaTachycardiaPacemaker Artificialmedicine.medical_specialtyDefibrillationHeart Ventriclesmedicine.medical_treatmentImplantable defibrillatorElectrocardiographyInternal medicineTachycardia SupraventricularmedicineHumansHeart AtriaProspective Studiescardiovascular diseasesLead (electronics)AgedEjection fractionbusiness.industryP waveGeneral MedicineMiddle AgedDefibrillators ImplantableElectrodes ImplantedEuropemedicine.anatomical_structureVentricleVentricular Fibrillationcardiovascular systemCardiologyFemalemedicine.symptomCardiology and Cardiovascular MedicinebusinessPacing and Clinical Electrophysiology
researchProduct

ICD Implantation in infants and small children: the extracardiac technique.

2007

There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…

Malemedicine.medical_specialtyDefibrillationmedicine.medical_treatmentAnterior wallElectric Countershock030204 cardiovascular system & hematologyProsthesis Implantation03 medical and health sciences0302 clinical medicinemedicineHumans030212 general & internal medicineLead (electronics)Childbusiness.industrySmall childrenInfantArrhythmias CardiacGeneral MedicineImplantable cardioverter-defibrillator3. Good healthIcd implantationSurgeryDefibrillators Implantablemedicine.anatomical_structureTreatment OutcomeVentricleChild PreschoolFemaleCardiology and Cardiovascular MedicinebusinessVertebral columnPacing and clinical electrophysiology : PACE
researchProduct

Active compression-decompression resuscitation: a prospective, randomized study in a two-tiered EMS system with physicians in the field.

1996

Improved cardiopulmonary circulation with active compression-decompression cardiopulmonary resuscitation (ACD-CPR) has been demonstrated in studies using different animal models and a small number of humans in cardiac arrest (CA). However, prehospital studies have shown both positive and no extra benefit of ACD-CPR on return of spontaneous circulation (ROSC), hospital admission and discharge rates. The aim of our prospective study was to compare standard manual CPR (S-CPR) with ACD-CPR as the initial technique of resuscitating patients with out-of-hospital CA, with respect to survival rates and neurological outcome. Patients with out-of-hospital CA treated by emergency medical services (EMS…

Malemedicine.medical_specialtyResuscitationEmergency Medical ServicesDefibrillationmedicine.medical_treatmenteducationEmergency NursingReturn of spontaneous circulationlaw.inventionRandomized controlled triallawhealth services administrationmedicineEmergency medical servicesHumanscardiovascular diseasesCardiopulmonary resuscitationProspective StudiesProspective cohort studyhealth care economics and organizationsbusiness.industryIntensive care unitSurvival AnalysisCardiopulmonary ResuscitationSurgeryTreatment OutcomeAnesthesiaEmergency MedicineFemaleCardiology and Cardiovascular MedicinebusinesstherapeuticsResuscitation
researchProduct

A novel technique to follow fast PaO2 variations during experimental CPR

2003

An ultrafast responding fluorescent-quenching PO2 probe allows time-resolved, in vivo measurement of PO2. This study describes several validation experiments of this new device in vitro, and reports its first use during cardiopulmonary resuscitation in an animal model of cardiac arrest.The influence of CO2, temperature and motion artefacts on the signal response of the PO2 probe was analysed in vitro by systematic variation of these values. Thereafter, with approval of the Review Board for the care and use of animals, CPR was performed in four pigs. The PaO2 course was recorded continuously at time resolution of80 ms in the abdominal aorta using an uncoated fluorescence-quenching probe (Fox…

Novel techniquemedicine.medical_specialtySwineDefibrillationPartial Pressuremedicine.medical_treatmentEmergency NursingSignalAnimal modelIn vivoIntensive caremedicineAnimalsFiber Optic TechnologyCardiopulmonary resuscitationFluorescent Dyesbusiness.industryTemperatureTime resolutionEquipment DesignCarbon DioxideCardiopulmonary ResuscitationHeart ArrestSurgeryOxygenDisease Models AnimalEmergency MedicineArtifactsCardiology and Cardiovascular MedicinebusinessBiomedical engineering