Safety and efficacy of implantable defibrillator therapy with programmed shock energy at twice the augmented step-down defibrillation threshold: resu…
1999
Whether the safety and efficacy of implantable cardioverter defibrillator (ICD) therapy can be assured with lower output devices is an important question. The purpose of this study was to evaluate whether programming the device output at twice the augmented defibrillation threshold was as safe and effective as using the maximum energy. Patients indicated for ICD therapy, but without slow monomorphic ventricular tachycardia (MVT), who achieved an augmented defibrillation threshold (DFT plus)or = 15 joules (J) with a single endocardial lead system and a biphasic defibrillator were included in the study. Prior to ICD implantation, patients were randomized into 2 groups. The shock energies in t…
Optimal Response to Cardiac Arrest study: Defibrillation waveform effects
2001
Abstract Introduction: Advances in early defibrillation access, key to the “Chain of Survival”, will depend on innovations in defibrillation waveforms, because of their impact on device size and weight. This study compared standard monophasic waveform automatic external defibrillators (AEDs) to an innovative biphasic waveform AED. Material and methods: Impedance-compensated biphasic truncated exponential (ICBTE) and either monophasic truncated exponential (MTE) or monophasic damped sine (MDS) AEDs were prospectively, randomly assigned by date in four emergency medical services. The study design compared ICBTE with MTE and MDS combined. This subset analysis distinguishes between the two clas…
Effektivit�t pr�klinischer Notfallversorgung Fiktion oder Fakt?
1996
The current increase in the cost of health care must be considered as a severe threat to the prehospital emergency services system. Two examples have been selected--the patient with polytrauma and the patient in cardiac arrest--to demonstrate the dilemma between a need for objective data and the requirements of emergency patients. Study results obtained in trauma patients indicating that total prehospital time, including scene time, is correlated to patient outcome have led to the conclusion that at the scene treatment by emergency physicians may be dispensable. It has, however also been demonstrated that the time required for medical treatment at the scene is equivalent to 20% of the total…
“Three-level shock” in ablation-refractory paroxysmal atrial fibrillation
1987
His-bundle ablation is a very effective method to control drug-refractory supraventricular arrhythmias. We present a 69-year-old woman with paroxysmal atrial fibrillation, in whom several attempts of unipolar and bipolar His-bundle ablation were ineffective. Ultimately a stable 2/1 atrioventricular block was induced when three successive shocks of 400 W were applied. The first shock was given in that position with the largest His-potential deflection. The other two shocks were applied at catheter positions more distal and more proximal from the first one, respectively. We suppose that the initial lack of success was due to an atypical atrioventricular junction anatomy.
Fibrilación ventricular con parada cardiorrespiratoria durante la administración de dexmedetomidina
2015
Protocol of a multicenter international randomized controlled manikin study on different protocols of cardiopulmonary resuscitation for laypeople (MA…
2018
IntroductionOut-of-hospital cardiac arrest is one of the leading causes of death in industrialised countries. Survival depends on prompt identification of cardiac arrest and on the quality and timing of cardiopulmonary resuscitation (CPR) and defibrillation. For laypeople, there has been a growing interest on hands-only CPR, meaning continuous chest compression without interruption to perform ventilations. It has been demonstrated that intentional interruptions in hands-only CPR can increase its quality. The aim of this randomised trial is to compare three CPR protocols performed with different intentional interruptions with hands-only CPR.Methods and analysisThis is a prospective randomise…
European Clinical Experience with a Dual Chamber Single Pass Sensing and Pacing Defibrillation Lead
2002
Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of…
ICD Implantation in infants and small children: the extracardiac technique.
2007
There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…
Active compression-decompression resuscitation: a prospective, randomized study in a two-tiered EMS system with physicians in the field.
1996
Improved cardiopulmonary circulation with active compression-decompression cardiopulmonary resuscitation (ACD-CPR) has been demonstrated in studies using different animal models and a small number of humans in cardiac arrest (CA). However, prehospital studies have shown both positive and no extra benefit of ACD-CPR on return of spontaneous circulation (ROSC), hospital admission and discharge rates. The aim of our prospective study was to compare standard manual CPR (S-CPR) with ACD-CPR as the initial technique of resuscitating patients with out-of-hospital CA, with respect to survival rates and neurological outcome. Patients with out-of-hospital CA treated by emergency medical services (EMS…
A novel technique to follow fast PaO2 variations during experimental CPR
2003
An ultrafast responding fluorescent-quenching PO2 probe allows time-resolved, in vivo measurement of PO2. This study describes several validation experiments of this new device in vitro, and reports its first use during cardiopulmonary resuscitation in an animal model of cardiac arrest.The influence of CO2, temperature and motion artefacts on the signal response of the PO2 probe was analysed in vitro by systematic variation of these values. Thereafter, with approval of the Review Board for the care and use of animals, CPR was performed in four pigs. The PaO2 course was recorded continuously at time resolution of80 ms in the abdominal aorta using an uncoated fluorescence-quenching probe (Fox…