Search results for "Defibrillation"

showing 10 items of 22 documents

Multicenter, Randomized, Controlled Trial of 150-J Biphasic Shocks Compared With 200- to 360-J Monophasic Shocks in the Resuscitation of Out-of-Hospi…

2000

Background —In the present study, we compared an automatic external defibrillator (AED) that delivers 150-J biphasic shocks with traditional high-energy (200- to 360-J) monophasic AEDs. Methods and Results —AEDs were prospectively randomized according to defibrillation waveform on a daily basis in 4 emergency medical services systems. Defibrillation efficacy, survival to hospital admission and discharge, return of spontaneous circulation, and neurological status at discharge (cerebral performance category) were compared. Of 338 patients with out-of-hospital cardiac arrest, 115 had a cardiac etiology, presented with ventricular fibrillation, and were shocked with an AED. The time from the e…

medicine.medical_specialtyResuscitationbusiness.industryDefibrillationmedicine.medical_treatmentReturn of spontaneous circulationmedicine.diseaseSurgerylaw.inventionRandomized controlled triallawPhysiology (medical)AnesthesiaVentricular fibrillationmedicineEmergency medical servicesCardiopulmonary resuscitationCardiology and Cardiovascular MedicinebusinessSurvival rateCirculation
researchProduct

Fibrilación ventricular con parada cardiorrespiratoria durante la administración de dexmedetomidina

2015

Defibrillationbusiness.industrymedicine.medical_treatmentAdvanced cardiac life supportMEDLINEElectric countershockCritical Care and Intensive Care MedicineDrug SubstitutionAnesthesiology and Pain MedicineAnesthesiamedicineDexmedetomidinebusinessPropofolmedicine.drugRevista Española de Anestesiología y Reanimación
researchProduct

Erstdefibrillation durch Not�rzte oder durch Rettungsassistenten?

1994

In a controlled prospective randomized study, defibrillation by emergency medical technicians (EMTs) was compared with the current standard of care in Germany (basic life support by EMTs and defibrillation by emergency physicians only) in order to answer the following questions: 1. Does EMT defibrillation improve the survival rate and long-term prognosis of patients in ventricular fibrillation as compared to the current German standards in resuscitation (basic life support by EMTs and defibrillation by emergency physicians)? 2. Are the prerequisites for the use of semiautomatic defibrillators fulfilled in the emergency medical systems (EMS) of the participating centers? Methods. The study p…

medicine.medical_specialtyResuscitationbusiness.industryDefibrillationmedicine.medical_treatmentAdvanced cardiac life supportGlasgow Coma ScaleBasic life support030208 emergency & critical care medicineGeneral Medicine030204 cardiovascular system & hematologyReturn of spontaneous circulationmedicine.disease3. Good health03 medical and health sciences0302 clinical medicineAnesthesiology and Pain MedicineInternal medicineAnesthesiaVentricular fibrillationCardiologymedicinebusinessSurvival rateDer Anaesthesist
researchProduct

186 Early Defibrillation in a Two-Tier Emergency Medical System (EMS) with Physician Staffed Ambulances

1993

medicine.medical_specialtybusiness.industryEmergency medicineEmergency MedicineMedicineMedical emergencyEmergency Nursingbusinessmedicine.diseaseEmergency medical systemEarly defibrillationPrehospital and Disaster Medicine
researchProduct

“Three-level shock” in ablation-refractory paroxysmal atrial fibrillation

1987

His-bundle ablation is a very effective method to control drug-refractory supraventricular arrhythmias. We present a 69-year-old woman with paroxysmal atrial fibrillation, in whom several attempts of unipolar and bipolar His-bundle ablation were ineffective. Ultimately a stable 2/1 atrioventricular block was induced when three successive shocks of 400 W were applied. The first shock was given in that position with the largest His-potential deflection. The other two shocks were applied at catheter positions more distal and more proximal from the first one, respectively. We suppose that the initial lack of success was due to an atypical atrioventricular junction anatomy.

Bundle of HisCardiac Catheterizationmedicine.medical_specialtyDefibrillationParoxysmal atrial fibrillationmedicine.medical_treatmentElectric CountershockElectrocardiographyInternal medicineAtrial Fibrillationmental disordersmedicineHumanscardiovascular diseasesAgedSupraventricular arrhythmiabusiness.industryAtrial fibrillationGeneral Medicinemedicine.diseaseAblationCatheterHeart Blockcardiovascular systemCardiologyFemaleSupraventricular tachycardiaCardiology and Cardiovascular MedicinebusinessAtrioventricular blockClinical Cardiology
researchProduct

ICD Implantation in infants and small children: the extracardiac technique.

2007

There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…

Malemedicine.medical_specialtyDefibrillationmedicine.medical_treatmentAnterior wallElectric Countershock030204 cardiovascular system & hematologyProsthesis Implantation03 medical and health sciences0302 clinical medicinemedicineHumans030212 general & internal medicineLead (electronics)Childbusiness.industrySmall childrenInfantArrhythmias CardiacGeneral MedicineImplantable cardioverter-defibrillator3. Good healthIcd implantationSurgeryDefibrillators Implantablemedicine.anatomical_structureTreatment OutcomeVentricleChild PreschoolFemaleCardiology and Cardiovascular MedicinebusinessVertebral columnPacing and clinical electrophysiology : PACE
researchProduct

Effektivit�t pr�klinischer Notfallversorgung Fiktion oder Fakt?

1996

The current increase in the cost of health care must be considered as a severe threat to the prehospital emergency services system. Two examples have been selected--the patient with polytrauma and the patient in cardiac arrest--to demonstrate the dilemma between a need for objective data and the requirements of emergency patients. Study results obtained in trauma patients indicating that total prehospital time, including scene time, is correlated to patient outcome have led to the conclusion that at the scene treatment by emergency physicians may be dispensable. It has, however also been demonstrated that the time required for medical treatment at the scene is equivalent to 20% of the total…

Artificial ventilationmedicine.medical_specialtyEmergency managementbusiness.industryDefibrillationmedicine.medical_treatmentMEDLINEGeneral Medicinemedicine.diseasePolytraumaAnesthesiology and Pain MedicineVentricular fibrillationHealth caremedicineCardiopulmonary resuscitationIntensive care medicinebusinessDer Anaesthesist
researchProduct

Safety and efficacy of implantable defibrillator therapy with programmed shock energy at twice the augmented step-down defibrillation threshold: resu…

1999

Whether the safety and efficacy of implantable cardioverter defibrillator (ICD) therapy can be assured with lower output devices is an important question. The purpose of this study was to evaluate whether programming the device output at twice the augmented defibrillation threshold was as safe and effective as using the maximum energy. Patients indicated for ICD therapy, but without slow monomorphic ventricular tachycardia (MVT), who achieved an augmented defibrillation threshold (DFT plus)or = 15 joules (J) with a single endocardial lead system and a biphasic defibrillator were included in the study. Prior to ICD implantation, patients were randomized into 2 groups. The shock energies in t…

AdultMalemedicine.medical_specialtyDefibrillationTest groupmedicine.medical_treatmentImplantable defibrillatorDefibrillation thresholdElectrocardiographyLow energyInternal medicineMedicineHumansProspective StudiesAgedEjection fractionEquipment Safetybusiness.industryMiddle AgedImplantable cardioverter-defibrillatorDefibrillators ImplantableSurvival RateTreatment OutcomeShock (circulatory)Ventricular FibrillationCardiologyTachycardia VentricularFemalemedicine.symptomCardiology and Cardiovascular MedicinebusinessSoftwareThe American journal of cardiology
researchProduct

Experimental study on the effects of physical training on the defibrillation threshold

2011

Background: Chest compression artifacts during cardiopulmonary resuscitation (CPR) deteriorate the rhythm diagnosis of automated external defibrillators (AED). Cardiopulmonary resuscitation must therefore be interrupted for a reliable shock/no-shock decision. However, these hands-off intervals adversely affect the defibrillation success, and, in addition, pauses in chest compressions compromise circulation. An accurate diagnosis of the rhythmwhile performing CPR is therefore needed to minimize these hands-off intervals. Methods: The characteristics of the CPR artifact are very variable, and the artifact presents an important spectral overlap with human cardiac arrest rhythms. Consequently, …

medicine.medical_specialtyArtifact (error)Compression artifactDefibrillationbusiness.industrymedicine.medical_treatmentmedicine.diseaseAdaptive filterDefibrillation thresholdInternal medicineVentricular fibrillationmedicineCardiologyCardiopulmonary resuscitationAsystoleCardiology and Cardiovascular MedicinebusinessJournal of Electrocardiology
researchProduct

[Is ICD-programming for double intraoperative defibrillation threshold energy safe and effective during long-time follow-up? Results of a prospective…

1999

The aim of this prospective and randomized study was to evaluate the safety and efficacy of a reduced shock strength in transvenous implantable defibrillator therapy. So far clinical data concerning the safety margin of the shock energy in ICD therapy do not exist. The shock energy tested during long-term follow-up in this study was twice the intraoperatively measured defibrillation threshold (DFT). A total number of 176 consecutive patients representing a typical cohort of ICD patients were evaluated. All patients received a non-thoracotomy lead system (CPI, Endotak 0070, 0090) and a biphasic cardioverter-defibrillator with the ability to store episodes (Cardiac Pacemakers Inc., Ventac TM …

inorganic chemicalsMalemedicine.medical_specialtyDefibrillationmedicine.medical_treatmentElectric CountershockImplantable defibrillatorAmiodaroneSudden cardiac deathlaw.inventionDefibrillation thresholdIntraoperative PeriodRandomized controlled triallawInternal medicinemedicineHumansProspective StudiesEquipment Safetybusiness.industryMiddle Agedmedicine.diseaseSurgeryDefibrillators ImplantableShock (circulatory)Ventricular fibrillationCardiologymedicine.symptomCardiology and Cardiovascular Medicinebusinessmedicine.drugFollow-Up StudiesZeitschrift fur Kardiologie
researchProduct