Search results for "Defibrillators"
showing 10 items of 25 documents
Implantation of a biventricular defibrillator in a borderline case of arrhythmogenic right ventricular dysplasia/cardiomyopathy
2014
European Clinical Experience with a Dual Chamber Single Pass Sensing and Pacing Defibrillation Lead
2002
Dual chamber ICDs are increasingly implanted nowadays, mainly to improve discrimination between supraventricular and ventricular arrhythmias but also to maintain AV synchrony in patients with bradycardia. The aim of this study was to investigate a new single pass right ventricular defibrillation lead capable of true bipolar sensing and pacing in the right atrium and integrated bipolar sensing and pacing in the right ventricle. The performance of the lead was evaluated in 57 patients (age 61 +/- 12 years; New York Heart Association 1.9 +/- 0.6, left ventricular ejection fraction 0.38 +/- 0.15) at implant, at prehospital discharge, and during a 1-year follow-up. Sensing and pacing behavior of…
Patient Alert to detect ICD lead failure: efficacy, limitations, and implications for future algorithms.
2006
Aims An algorithm that alerts implantable cardioverter-defibrillator (ICD) patients, in case of abnormal lead impedance (Patient Alert™, Medtronic), may help to recognize lead dysfunction. We aimed to determine the utility of Patient Alert for ICD lead-failure detection in a prospective study. Methods and results Three hundred and sixty ICD patients were followed for 22±14 months. Patient Alert was active for pacing impedance 2000–3000 Ω, and high-voltage conductor impedance 200 Ω. Ten alert events and a total of 29 severe system complications occurred. Patient Alert detected three of 10 ICD lead failures, with a positive predictive value (PPV) of 77.8% for any severe system complication. R…
Prophylactic Implantable Cardioverter Defibrillator Placement in a Sporadic Desmin Related Myopathy and Cardiomyopathy
2004
Desminopathy is a neuromuscular disorder associated with the accumulation of the protein desmin. This article reports a case of a man with a mutation in the desmin gene suffering from cardiomyopathy and skeletal myopathy. This patient underwent implantable cardioverter defibrillator (ICD) implantation for prognostic considerations and subsequently developed a sustained ventricular tachycardia (SVT). While nonsustained VTs (NSVT) have previously been reported, this is the first time that a SVT could be seen in a patient with this disease.
ICD Implantation in infants and small children: the extracardiac technique.
2007
There is no clear methodology for implantation of an internal cardioverter-defibrillator (ICD) in infants and small children. The aim of this study was to assess efficacy and safety of an extracardiac ICD implantation technique in pediatric patients.An extracardiac ICD system was implanted in eight patients (age: 0.3-8 years; body weight: 4-29 kg). Under fluoroscopic guidance a defibrillator lead was tunneled subcutaneously starting from the anterior axillar line along the course of the 6th rib until almost reaching the vertebral column. After a partial inferior sternotomy, bipolar steroid-eluting sensing and pacing leads were sutured to the atrial wall (n = 2) and to the anterior wall of t…
Clinical Benefit of Cardiac Resynchronization Therapy With a Defibrillator in Patients With an Ejection Fraction > 35% Estimated by Cardiac Magnet…
2014
A B S T R A C T Introduction and objectives: Cardiac resynchronization therapy with a defibrillator prolongs survival and improves quality of life in advanced heart failure. Traditionally, patients with ejection fraction > 35 estimated by echocardiography have been excluded. We assessed the prognostic impact of this therapy in a group of patients with severely depressed systolic function as assessed by echocardiography but with an ejection fraction > 35% as assessed by cardiac magnetic resonance. Methods: We analyzed consecutive patients admitted for decompensated heart failure between 2004 and 2011. The patients were in functional class II-IV, with a QRS to 120 ms, ejection fraction 35% es…
Natural history of the Sprint Fidelis lead: survival analysis from a large single-center study.
2012
The purposes of our study were to: (1) determine lead failure rate in a large single-center cohort of Sprint Fidelis 6949 (Fidelis) leads, (2) define the risk of lead failure over time, (3) assess the impact of the Lead Integrity Alert (LIA) on lead failure presentation, and (4) identify independent predictors of Fidelis lead failure. All patients who underwent implantation of a Fidelis lead between September 2004 and July 2007 were included. Demographic, clinical, and device characteristics at the time of implant and prior to failure were collected and analyzed. A total of 971 Fidelis leads (706 men, 265 women, mean age 68.4 ± 12.8 years) were implanted. Over a mean follow-up of 46.3 month…
Efficacy of a web-based intervention for improving psychosocial well-being in patients with implantable cardioverter-defibrillators: the randomized c…
2019
Abstract Aims Anxiety, depression, and reduced quality of life (QoL) are common in patients with implantable cardioverter-defibrillators (ICDs). Treatment options are limited and insufficiently defined. We evaluated the efficacy of a web-based intervention (WBI) vs. usual care (UC) for improving psychosocial well-being in ICD patients with elevated psychosocial distress. Methods and results This multicentre, randomized controlled trial (RCT) enrolled 118 ICD patients with increased anxiety or depression [≥6 points on either subscale of the Hospital Anxiety and Depression Scale (HADS)] or reduced QoL [≤16 points on the Satisfaction with Life Scale (SWLS)] from seven German sites (mean age 58…
Should subcutaneous implantable cardioverter-defibrillators be implanted in patients who are candidates for continuous flow left ventricular assist d…
2017
Mortality after cardioverter-defibrillator replacement: Results of the DECODE survival score index
2020
Background Device replacement is the ideal time to reassess health care goals regarding continuing implantable cardioverter-defibrillator (ICD) therapy. Only few data are available on the decision making at this time. Objectives The goals of this study were to identify factors associated with poor prognosis at the time of ICD replacement and to develop a prognostic index able to stratify those patients at risk of dying early. Methods DEtect long-term COmplications after implantable cardioverter-DEfibrillator replacement (DECODE) was a prospective, single-arm, multicenter cohort study aimed at estimating long-term complications in a large population of patients who underwent ICD/cardiac resy…