Volumetric variation of peri-implant soft tissues in convergent collar implants and crowns using the biologically oriented preparation technique (BOP…
2018
Background To evaluate the changes in the peri-implant soft tissues of convergent collar implants with biologically oriented preparation technique (BOPT) crowns, 10 months after loading. Material and Methods A pilot study was carried out from January 2016 to October 2017 involving 14 patients with one or two implants in the posterior mandibular sector. A total of 32 convergent collar implants were placed using a non-submerged protocol. Three months later the provisional cemented crowns were fitted using the BOPT approach with the finish line 1-1.5 mm below the gingival margin, simulating coronal emergence of a natural tooth. The soft tissue changes were measured with an intraoral scanner at…
Torque de desinserción y propiedades fisico-químicas de implantes dentales grabados con ácidos fluorhídrico y nítrico: Estudio experimental en perros
2006
Objetivo: Estudiar la composición, características superficiales y respuesta al torque de desinserción de una superficie implantaria tratada inicialmente con ácido fluorhídrico y posterior pasivado con ácidos fluorhídrico y nítrico. Diseño del estudio: En una primera fase, se seleccionaron 12 implantes en los que se estudiaron las características fisico-químicas mediante mediciones de energía dispersa de rayos X (EDS), microscopio electrónico de barrido y análisis de XPS (espectrometría de fotoelectrones). Asimismo, se colocaron 24 implantes -doce de 8 mm y doce de 10 mm de longitud-, en seis perros beagle, en los que tras un período de reposo, se procedió a la retirada de 12 implantes a la…
Effect of bone loss on the fracture resistance of narrow dental implants after implantoplasty. An in vitro study
2021
Background Implantoplasty (IP) involves polishing of the exposed surface of implants affected by peri-implantitis (PI). A study was made to determine whether the degree of bone loss influences the fracture resistance of implants with or without IP. Material and Methods An in vitro study was carried out on 32 narrow (3.5 mm) dental implants with a rough surface and external hexagonal connection. Implantoplasty was performed in half of the implants of the sample. Both the IP and control implants were divided into two subgroups according to the amount of bone loss (3 mm or 7.5 mm). Standardized radiographic assessment of implant width was performed using specific software. The main outcome var…
Infections in implantology: From prophylaxis to treatment
2007
Since the introduction of osseointegrated implant treatment, odontology, and in particular the area of prosthodontic replacement of lost teeth, has evolved in an unimaginable way, to the extent that the age-old idea of "restitutio ad integrum" has almost become possible. Implant treatment has a high success rate that has been rated as high as 95 to 99%, according to different casuists, but there is another group of cases in which implants fail, and in fact it is hard to know the causes of such failures. The microbiological component plays an important role in encouraging and facilitating implant infection during implant placement, and also later when the implant is in function in the mouth,…
Relation between bone density and primary implant stability
2010
Aims: This study aims to relate bone density in Hounsfield units (Hu) with the primary implant stability measured by insertion torque (Ncm) and resonance frequency analysis (ISQ). Materials and Methods: Ten patients were included in this study. A total of 54 implant sites were provided from 10 computerized tomography scans. The computerized tomography scan was used for the preoperative evaluation of bone density for each patient. The bone mean density around planned implants was determined with Physioplanet TM software. Bone quality according resistance to drilling, insertion torque and resonance frequency measurements were recorded. Results: A statistically significant relationship was obs…
Implant insertion torque value in immediate loading : a retrospective study
2019
Background The aim of this study is to verify if the Insertion Torque Value (ITV) of 32 Ncm for immediate loading protocol (ILP), as indicated by literature, is still, with the advance in implant research, a real significant cut-off for long-term implant survival. Material and Methods In this retrospective study, data from 224 patients that during three years of clinical practice, were submitted to the insertion of 322 implants with immediate loading protocol, have been recorded, pooled and analyzed. Data were organized based on Insertion Torque Value (ITV): > 32 Ncm (CG) and 32 Ncm are still characterized by a lower crestal bone resorption, there are no statistically significant difference…
Assessment of Osstell ISQ's reliability for implant stability measurement: a cross-sectional clinical study
2013
Resonance frequency analysis (RFA) allows assess implant stability by measuring implant oscillation frequency on the bone. RFA is an objective and non-invasive method for implant stability measurement, although scarce evidence has been provided so far on its reliability. Objectives: Assess the Osstell ISQ system's reliability (i.e., its measurement reproducibility and repeatability) by means of the intraclass correlation coefficient (ICC) as statistical method. Study Desing: Implants stability registers were completed by means of Osstell ISQ on 85 implants on 23 patients. Six measurements were completed on each implant by means of two different SmartPegs (types I and II); that is, three con…
Thermal increment due to ErCr: YSGG and CO2 laser irradiation of different implant surfaces. A pilot study
2010
Podeu consultar la versió en castellà http://hdl.handle.net/2445/118903
Impact of crestal and subcrestal implant placement upon changes in marginal peri-implant bone level. A systematic review.
2019
Background To systematically assess studies analyzing peri-implant bone loss in implants placed in crestal and subcrestal position. Material and Methods Following the recommended methods for systematic reviews and meta-analyses (PRISMA), an electronic search was conducted in the PubMed (MEDLINE), EMBASE and LILACS databases to identify all relevant articles published up until April 2017. The search included human studies comparing marginal bone loss (MBL) between a control group and a study group with a minimum of 10 patients and a minimum follow-up of 6 months after prosthetic loading with rough neck implants. Two independent reviewers assessed the risk of bias in the selected studies base…
Retrospective study of the bone morphology in the posterior mandibular region. Evaluation of the prevalence and the degree of lingual concavity and t…
2016
Background In order to choose the appropriate implant size and to prevent complications, an oral surgeon must know the size and shape of the mandible. In the posterior mandibular region, a lingual undercut is often found and could represent a difficulty hard to manage if a lingual or buccal perforation occur. A large series of computed tomography (CT) images of the mandibular first molar was evaluated and the bone morphology, the prevalence and the degree of the lingual concavity in the first molar region were studied. Material and Methods One hundred and fifty-one computed tomography (CT) examinations of patients were retrospectively evaluated to determine anatomical variations in bone mor…