Search results for "Dental Prosthesis"

showing 10 items of 135 documents

Biological and technical complications of tilted implants in comparison with straight implants supporting fixed dental prostheses. A systematic revie…

2018

OBJECTIVES To evaluate the implant failure, marginal bone loss (MBL), and other biological or technical complications of restorations supported by tilted and straight implants after at least 3 years in function. METHODS Electronic and manual searches were performed in MEDLINE, Embase, Web of Science, and OpenGrey to identify clinical studies published up to December 2017. After duplicate study selection and data extraction, the risk of bias was assessed with the ROBINS-I tool. Random-effects meta-analyses of relative risks (RRs) or mean differences (MD) and their 95% confidence intervals (CIs) were performed, followed by subgroup/sensitivity analyses and application of the GRADE approach. R…

Web of scienceMEDLINEDentistry610 Medicine & health10067 Clinic for Orthodontics and Pediatric DentistryDental Prosthesis03 medical and health sciences10068 Clinic of Reconstructive Dentistry0302 clinical medicineHumansMedicineDental Restoration Failure030212 general & internal medicine610 Medicine & healthbusiness.industry3504 Oral SurgeryDental Implantation EndosseousImplant failureRetrospective cohort study030206 dentistryConfidence intervalMeta-analysisRelative riskDental Prosthesis Implant-SupportedImplantOral Surgerybusiness
researchProduct

Effect of thermocycling with or without 1 year of water storage on retentive strengths of luting cements for zirconia crowns

2015

Abstract Statement of problem Bond stability between zirconia crowns and luting cement and between cement and dentin is a main concern; however, only limited evidence is available as to its longevity. Purpose The purpose of this in vitro study was to measure the retentive strengths of 7 self-adhesive cements (RelyX Unicem Aplicap, RelyX Unicem Clicker, RelyX Unicem 2 Automix, iCEM, Maxcem Elite, Bifix SE, SpeedCem), 2 adhesive cements with self-etch primers (Panavia 21, SEcure), 1 glass ionomer cement (Ketac Cem), 1 resin-modified glass ionomer cement (Meron Plus), and 1 zinc phosphate cement for luting zirconia crowns (LAVA) to extracted teeth after thermocycling with or without 1 year of …

Zinc Phosphate CementTime FactorsMaterials scienceGlass ionomer cementDental CementsDentistryDental bondingComposite ResinsPhosphatesDental Prosthesis RetentionDental MaterialsMaterials TestingDentinmedicineHumansCubic zirconiaLimited evidenceCementationCementPolycarboxylate CementCrownsbusiness.industryDental BondingTemperatureWaterDental PolishingResin Cementsmedicine.anatomical_structureGlass Ionomer CementsZirconiumAdhesiveZinc OxideOral SurgeryMagnesium OxidebusinessZinc Phosphate CementThe Journal of Prosthetic Dentistry
researchProduct

Evaluation of the primary stability in dental implants placed in low density bone with a new drilling technique, osseodensification: an in vitro study

2020

Background Primary stability is an important key determinant of implant osseointegration. We investigated approaches to improve primary implant stability using a new drilling technique termed osseodensification (OD), which was compared with the conventional under-drilling (UD) method utilized for low-density bones. Material and Methods We placed 55 conical internal connection implants in each group, in 30 low-density sections of pig tibia. The implants were placed using twist drill bits in both groups; groups Under Drilling (UD) and Osseodensification (OD) included bone sections subjected to conventional UD and OD drilling, respectively. Before placing the implants, we randomized the bone s…

computer-assisted diagnosisMaterials scienceSwinecomputer-assisted image processingOsseointegrationDental Prosthesis Retentionradicular cysts03 medical and health sciences0302 clinical medicineBone DensityOsseointegrationLow densityAnimalscomputer-assisted image analysisIn vitro studyTibiaGeneral DentistryUNESCO:CIENCIAS MÉDICASInternal connectionDental ImplantsResearchTwist drillDental Implantation EndosseousResonance Frequency Analysis030206 dentistryResonance frequency analysisTorqueOtorhinolaryngologykeratocystsodontogenic cystsSurgeryImplantImplantologyBiomedical engineering
researchProduct

Recurrent central giant cell granuloma in the mandible: surgical treatment and dental implant restoration.

2007

Central giant cell granuloma is an uncommon benign intraosseus lesion of jaws. Traditional treatment has been local curettage, although aggressive sub-types have a high tendency to recur. This patient report describes a recurrent central giant cell granuloma involving the body of the mandible in a 48-year-old-woman. Initial treatment of lesion consisted of curettage and peripheral ostectomy. When recurrence was detected one year later, an en bloc resection and defect regeneration with a composite bone graft of autogenous bone, xenograft, and autologous platelet-rich plasma was carried out. Adequate new bone formation was observed during follow-up of 24 months. Two dental implants were place…

dental implantsMandíbulaUNESCO::CIENCIAS MÉDICAScélula gigantedental prosthesisMandiblegiant cellimplante dental:CIENCIAS MÉDICAS [UNESCO]granulomaprótesis dental
researchProduct

Randomized multicenter comparison of two coatings of intramobile cylinder implants in 313 partially edentulous mandibles followed up for 5 years

2002

Intramobile cylinder (IMZ) implants with either of two coatings, hydroxyapatite (HA) or titanium plasma-flame (TPF), as distal abutments for combined tooth implant-supported restorations, were compared in 313 partially edentulous mandibles with respect to postprosthetical failure patterns and complication frequencies in a randomized multicenter clinical trial. Within the treatment protocols, the two coatings do not show evidence of different efficacy with respect to occurrence of postprosthetical integration deficiency (ID) or functional deficiency (FD). Statistical equivalence for an absolute effect of +/-15% in event-free survival could only be demonstrated for FD, not for ID, however. In…

education.field_of_studyProportional hazards modelbusiness.industryTreatment outcomeDental prosthesisPopulationSignificant differenceDentistrylaw.inventionRandomized controlled triallawMedicineImplantOral SurgerybusinesseducationProspective cohort studyClinical Oral Implants Research
researchProduct

Is clinical experience important for obtaining the primary stability of dental implants with aggressive threads? An ex vivo study

2018

GECKILI, ONUR/0000-0002-7852-3915; dayan, suleyman cagatay/0000-0003-3081-9618; Bilhan, Hakan/0000-0003-1787-3003 WOS:000460131200015 PubMed ID: 30818319 Background: The aim of this study was to investigate the clinicians' experience on maintaining the primary stability of implants with aggressive threads belonging to a novel dental implant system. Material and Methods: Three hundred implants with aggressive threads were inserted in fresh bovine ribs mimicking Type IV bone by five clinicians which were classified according to their previous experience of total number of implant insertion. An independent examiner measured the primary stability of all implants after insertion by using resonan…

experimental designmedicine.medical_treatmentDentistryIn Vitro TechniquesOsseointegration03 medical and health sciences0302 clinical medicineOsseointegrationmedicineDental Prosthesis DesignAnimalsDental implantGeneral DentistryDental Implantsbusiness.industryResearchDental Implantation EndosseousDental Modelsosseointegration030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Models DentalBiomechanical PhenomenaResonance frequency analysisDental Implant-Abutment DesignOtorhinolaryngologyDental Prosthesis DesignTorqueResearch DesignUNESCO::CIENCIAS MÉDICASSurgeryCattleImplantOral SurgerybusinessImplantologyEx vivo
researchProduct

Assessing osseointegration of metallic implants with boronized surface treatment

2020

Background Modification of endosteal implants through surface treatments have been investigated to improve osseointegration. Boronization has demonstrated favorable mechanical properties, but limited studies have assessed translational, in vivo outcomes. This study investigated the effect of implant surface boronization on bone healing. Material and Methods Two implant surface roughness profiles (acid etched, machined) in CP titanium (type II) alloy implants were boronized by solid-state diffusion until 10-15µm boron coating was achieved. The surface-treated implants were placed bilaterally into 5 adult sheep ilia for three and six weeks. Four implant groups were tested: boronized machined …

inorganic chemicalsBone RegenerationMaterials scienceSurface Propertieschemistry.chemical_elementBone healingOsseointegration03 medical and health sciences0302 clinical medicineOsseointegrationAnimalsBone regenerationGeneral DentistryDental ImplantsTitaniumSheepResearchDental Implantation Endosseous030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Bone to implant contactDental Prosthesis DesignOtorhinolaryngologychemistryUNESCO::CIENCIAS MÉDICASImplant typesSurgeryImplantAdult sheepImplantologyBiomedical engineeringTitaniumMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Four color-measuring devices compared with a spectrophotometric reference system

2009

Abstract Objectives The objective of this study was to compare the L*C*h° color coordinates of dental color-measuring devices with those of a spectrophotometric reference system. Methods The International Commission on Illumination (CIE) L*C*h° color coordinates of ceramic samples, matching the colors of the VITA Linearguide, were recorded using four color-measuring devices (VITA Easyshade (A), VITA Easyshade compact (B), Degudent Shadepilot (C), X-Rite Shadevision (D)) and a spectrophotometric reference system under standardized test conditions. The intraclass correlation coefficients, regression lines with coefficients of determination, and mean deviations of the dental color-measuring de…

medicine.diagnostic_testProsthesis ColoringIntraclass correlationAnalytical chemistryColorReproducibility of ResultsRepeatabilityDental Prosthesis DesignSpectrophotometrySpectrophotometryLinear regressionLinear ModelsmedicineMeasuring instrumentHumansTooth DiscolorationColorimetryColorimetryGeneral DentistryColor coordinatesHueMathematicsJournal of Dentistry
researchProduct

Implants in patients with oral manifestations of autoimmune or muco-cutaneous diseases – A systematic review

2018

Background To give an overview on implant survival rates in patients with oral manifestations of systemic autoimmune (oral Lichen planus (oLp), Pemphigus (Pe)), muco-cutaneous (Epidermolysis bullosa (EB)), autoimmune multisystemic rheumatic diseases (Sjögren´s syndrome (SjS), systemic Lupus erythematosus (sLE), or systemic Sclerosis (sSc)). Material and Methods Systematic literature review (PubMed/Medline, Embase) using MESH and search term combinations, published between 1980 and August 2018 in English language reporting on dental implant-prosthetic rehabilitation of patients with oLp, Pe, EB, SjS, sLE, sSc, study design, age, gender, follow-up period (≥ 12 months), implant survival rate. …

medicine.medical_specialtyDatabases FactualReviewScleroderma03 medical and health sciences0302 clinical medicinemedicineHumansLupus Erythematosus SystemicDental Restoration Failureskin and connective tissue diseasesGeneral DentistrySurvival rateDental ImplantsScleroderma SystemicLupus erythematosusintegumentary systembusiness.industryDental prosthesis030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Medically compromised patients in Dentistrymedicine.diseaseDermatologystomatognathic diseasesPemphigusSjogren's SyndromeTreatment OutcomeOtorhinolaryngologyUNESCO::CIENCIAS MÉDICASSurgeryOral lichen planusDental Prosthesis Implant-SupportedImplantEpidermolysis bullosaEpidermolysis BullosaMouth DiseasesbusinessPemphigusLichen Planus OralMedicina Oral Patología Oral y Cirugia Bucal
researchProduct

Influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient satisfaction

2016

Background: To assess the influence of the prosthetic arm length (palatal position) of zygomatic implants upon patient comfort and stability, speech, functionality and overall satisfaction. Material and Methods: A retrospective clinical study was made of patients subjected to rehabilitation of atrophic maxilla with complete maxillary implant-supported fixed prostheses involving a minimum of two zygomatic implants (one on each side) in conjunction with premaxillary implants, and with 12 months of follow-up after implant loading. Subjects used a VAS to score general satisfaction, comfort and stability, speech and functionality, and the results were analyzed in relation to the prosthetic arm l…

medicine.medical_treatmentDentistryOdontologíaRetrospective data03 medical and health sciences0302 clinical medicinePatient satisfactionGeneral satisfactionMaxillaAtrophic maxillaHumansJaw EdentulousMedicine030212 general & internal medicineImplant loadingGeneral DentistryRetrospective StudiesPatient comfortDental ImplantsZygomaRehabilitationbusiness.industryResearchDental Implantation Endosseous030206 dentistry:CIENCIAS MÉDICAS [UNESCO]Ciencias de la saludTreatment OutcomeOtorhinolaryngologyPatient SatisfactionMaxillaUNESCO::CIENCIAS MÉDICASSurgeryDental Prosthesis Implant-SupportedOral SurgerybusinessFollow-Up Studies
researchProduct