Search results for "Dental prosthesis design"
showing 10 items of 62 documents
A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Ma…
2012
Background: The use of endosseous dental implants has become common practice for the rehabilitation of edentulous patients, and a two-implant overdenture has been recommended as the standard of care. The use of small-diameter implants may extend treatment options and reduce the necessity for bone augmentation. However, the mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. Purpose: This randomized, controlled, double-blind, multicenter study investigated in a split-mouth model whether small-diameter implants made from Titanium-13Zirconium alloy (TiZr, Roxolid™) perform at least as well as Titanium Grade IV implants. Me…
Analysis of marginal bone loss and implant stability quotient by resonance frequency analysis in different osteointegrated implant systems. Randomize…
2019
Background The aim of the present prospective clinical study is to compare the stability of the implant-bone interface by the ISQ quotient and marginal bone loss (MBL) rate during one year of follow-up in four system implants with the same surface and different design. Material and Methods Prospective randomized clinical trial of 21 patients in which four implant systems with the same surface and different design were placed. Patients were treated by the same operator following a similar surgical protocol with submerged technique. The second surgery to perform the prosthesis was performed at 3 months. All patients went to their review at 6 months and a year. A periapical radiograph for cres…
Zirconia Removable Telescopic Dentures Retained on Teeth or Implants for Maxilla Rehabilitation. Three-Year Observation of Three Cases
2010
Abstract This report addresses maxillary restoration with removable telescopic crown-retained palatal free dentures. One patient with 7 natural teeth (PERIO), a second patient with 6 dental implants (IMPL), and a third patient with 2 natural teeth and 4 dental implants (IMPL-PERIO) were treated. Zirconia copings for natural teeth and individual zirconia implant abutments were fabricated in CAD/CAM and used as primary crowns. Electroformed gold copings were used as secondary telescopes. All maxilla supraconstructions were fabricated with zirconia and CAD/CAM. Patients were monitored during a 3-year period; all teeth and implants survived, and no biological or mechanical complications occurre…
Osseointegration of one-piece zirconia implants compared with a titanium implant of identical design: a histomorphometric study in the dog
2010
Objective: The aim of this study was to evaluate osseointegration of one-piece zirconia vs. titanium implants depending on their insertion depth by histomorphometry. Material and methods: Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: (1) an uncoated zirconia implant, (2) a zirconia implant coated with a calcium-liberating titanium oxide coating, (3) a titanium implant and (4) an experimental implant made of a synthetic material (polyetheretherketone). In a split-mouth manner they were inserted in submerged and non-submerged gingival healing modes. After 4 months, dissected blocks were stained with toluidine blue in order to histologically asse…
Repeatability of the resonance frequency analysis values in implants with a new technology
2019
Background Assess the reliability (by means of reproducibility and repeatability) of the PenguinRFA system, analyse the ISQ values of different implant types and correlate the ISQ with the insertion torque during the placement of the implant. Material and Methods 120 rough surface implants were placed in bovine bone (type II and III). The implants were divided into groups, according to its design. Once the implants were in place, the exact insertion torque was registered. Then, primary stability was measured by means of the resonance frequency analysis with the PenguinRFA and the Osstell ISQ devices. In each implant two transducers of each device were used. Three measurements were obtained …
The role of angiogenesis in implant dentistry part I: Review of titanium alloys, surface characteristics and treatments
2015
Background: Angiogenesis plays an important role in osseointegration process by contributing to inflammatory and regenerative phases of surrounding alveolar bone. The present review evaluated the effect of titanium alloys and their surface characteristics including: surface topography (macro, micro, and nano), surface wettability/ energy, surface hydrophilicity or hydrophobicity, surface charge, and surface treatments of dental implants on angiogenesis events, which occur during osseointegration period. Material and Methods: An electronic search was performed in PubMed, MEDLINE, and EMBASE databases via OVID using the keywords mentioned in the PubMed and MeSH headings regarding the role of …
Vertical osteoconductivity and early bone formation of titanium-zirconium and titanium implants in a subperiosteal rabbit animal model.
2013
Objectives The aim of this pilot study was to evaluate the vertical osteoconductive and osteointegrative dynamics around titanium–zirconium (TiZr) implants compared to titanium (Ti) implants. Materials and methods In a split-leg design, 12 TiZr-SLActive and 12 Ti-SLActive implants were inserted 3 mm above bone level in the proximal tibia of 12 rabbits. Full periosteal flaps were repositioned to cover the site. Specimens were obtained after 10, 20 and 30 days (each n = 4 per group). Histomorphometric measurements included percentage of linear bone fill (PLF; %), new marginal vertical bone height (VBH; mm) and vertical bone-to-implant contact (vBIC; %). Statistical analysis was performed with…
Soft Tissue Healing at One-Piece Zirconia Implants Compared to Titanium and PEEK Implants of Identical Design: A Histomorphometric Study in the Dog
2013
This study aimed to histomorphometrically evaluate the soft tissue reactions of one-piece zirconia implants versus titanium implants in regard to their insertion depth. Four one-piece implants of identical geometry were inserted on each side of six mongrel dogs: an uncoated zirconia implant, a zirconia implant coated with a calcium liberating titanium oxide, a titanium implant, and an experimental implant made of a synthetic material. Using a split-mouth design, they were inserted in both submerged and nonsubmerged healing modes. After 4 months, dissected blocks were stained with toluidine blue to histologically assess the marginal portion of the implant mucosa, apical extension of the barr…
The implant-supported milled bar overdenture : a literature review
2008
Purpose: This bibliographical review aims to determine the present situation of the implant-supported milled bar overdenture as a therapeutic option in implantology, as well as to set and compare the techniques and materials currently used for making them. Materials and methods: By searching the main electronic bibliographical data in indexed Medline articles, we obtained a total number of 20 articles that fulfilled the requirements of this bibliographical review. Results: The implant-supported milled bar overdenture offers excellent long-term successful results, although complication rates are higher in emergency cases of patients initially planned for a fixed prosthesis. Krenmair and coll…
Peri-implant defect grafting with autogenous bone or bone graft material in immediate implant placement in molar extraction sites-1- to 3-year result…
2020
Objectives To evaluate the survival rate, the orobuccal bone resorption and stability of peri-implant hard and soft tissues following immediate implant placement of wide diameter implants in molar extraction sites and peri-implant defect grafting with autogenous bone (AB) or biphasic bone graft material (BBGM) with 1- to 3-year follow-up examinations. Material and methods Fifty wide diameter implants were placed in 50 patients immediately into molar extraction sockets by a flapless approach. Peri-implant defect augmentation was performed randomized with either AB or BBGM. Primary outcome variable was implant survival. Marginal bone level changes, orobuccal width of the alveolar crest, probi…