Search results for "Derivatization"

showing 10 items of 215 documents

One-Pot Analysis: a New Integrated Methodology for Determination of TAG and FA Determination through LC/MS and in-silico Saponification

2017

Vegetable oils differ significantly for their lipid profile and are mainly constituted by triacylglycerols (TAGs). These are esters formed bonding glycerol to three fatty acids (FAs). To the best of our knowledge, FA and TAG profiles in oils and fats are obtained using at least two different experimental techniques. In particular, FA determination requires elaborated procedures for sample preparation and analyte derivatization. In this work, we propose a one-pot analysis able to determine both TAG and FA contents of edible oils, using experimental data obtained from a simple liquid chromatography/mass spectrometry determination of TAGs. This experimental procedure is followed by an in silic…

AnalyteMass spectrometryTriacylglycerol01 natural sciencesApplied Microbiology and BiotechnologyAnalytical Chemistrychemistry.chemical_compound0404 agricultural biotechnologyLiquid chromatography–mass spectrometryGlycerolSample preparationFood scienceSafety Risk Reliability and QualityDerivatizationChromatography010401 analytical chemistry04 agricultural and veterinary sciencesFatty acid040401 food scienceFAME0104 chemical sciencesLipid profileVegetable oilBlood chemistrychemistryIn silico saponificationSafety ResearchSaponificationFood ScienceFood Analytical Methods
researchProduct

Determination of amphetamines in hair by integrating sample disruption, clean-up and solid phase derivatization

2016

The utility of matrix solid phase dispersion (MSPD) for the direct analysis of amphetamines in hair samples has been evaluated, using liquid chromatography (LC) with fluorescence detection and precolumn derivatization. The proposed approach is based on the employment of MSPD for matrix disruption and clean-up, followed by the derivatization of the analytes onto the dispersant-sample blend. The fluorogenic reagent 9-fluorenylmethyl chloroformate (FMOC) has been used for derivatization. Different conditions for MSPD, analyte purification and solid phase derivatization have been tested, using amphetamine (AMP), methamphetamine (MET), ephedrine (EPE) and 3,4-methylenedioxymethamphetamine (MDMA)…

AnalyteN-Methyl-34-methylenedioxyamphetamine02 engineering and technologyChloroformate01 natural sciencesBiochemistryMethamphetamineAnalytical ChemistryMatrix (chemical analysis)chemistry.chemical_compoundmedicineHumansEphedrineDerivatizationFluorescent DyesEphedrineDetection limitFluorenesChromatographyAmphetamines010401 analytical chemistryOrganic ChemistryGeneral Medicine021001 nanoscience & nanotechnology0104 chemical sciencesClean-upAmphetaminechemistryReagent0210 nano-technologyChromatography LiquidHairmedicine.drugJournal of Chromatography A
researchProduct

Strategies for the enantiomeric determination of amphetamine and related compounds by liquid chromatography.

2002

This paper summarizes recent research on the stereospecific analysis of amphetamine, its analogs and metabolites, by liquid chromatography. The different methods proposed have been evaluated and compared in terms of resolution power, time of analysis, sensitivity, or potential for automation. Chiral derivatization, followed by separation of the diastereomers formed in achiral chromatographic systems, is still the method preferred for the analysis of amphetamines at trace levels, as derivatization also improves analyte detectability. This is the method of choice for the enantiomeric analysis of amphetamines at the low concentrations typically encountered in biological samples. In recent year…

AnalyteResolution (mass spectrometry)medicine.drug_classBiophysicsBiochemistrySensitivity and Specificitychemistry.chemical_compoundIsomerismmedicineHumansEphedrineDerivatizationAmphetamineChromatography High Pressure LiquidChromatographyStaining and LabelingIllicit DrugsAmphetaminesDiastereomerReproducibility of ResultsDesigner drugSubstance Abuse DetectionchemistryModels ChemicalEnantiomermedicine.drugChromatography LiquidJournal of biochemical and biophysical methods
researchProduct

More about sampling and estimation of mercaptans in air samples

2013

[EN] Several strategies have been developed for sampling and determination of volatile thiols. The selectivity and sensitivity of the proposed methodologies are achieved by using a specific derivatizing reagent. The different procedures assayed are based on air sampling followed by derivatization of the analytes with OPA and isoleucine in alkaline solution. The derivatization products are separated and determined by liquid chromatography and fluorescence detection. To start, the derivatization conditions and stability of the derivates have been studied in order to establish the storage conditions. In general, the strategies studied consisted on trapping and detivatization the thiol compound…

AnalyteSorbentAir samplesAlkaliesHigh-performance liquid chromatographyAnalytical ChemistryCartridgeO-Phthalaldehydechemistry.chemical_compoundMercaptansQUIMICA ANALITICAHumansSulfhydryl CompoundsIsoleucineDerivatizationAir sampling systemFluorescent DyesAir PollutantsChromatographyAirSampling (statistics)DerivatizationSolutionsSpectrometry FluorescencechemistryReagentCalibrationHPLCo-PhthalaldehydeChromatography Liquid
researchProduct

Clean analytical method for the determination of propoxur

1995

Abstract A method has been developed for the determination of propoxur, a carbamate pesticide, by means of its reaction with p-aminophenol (PAP). The method involves the reaction, in the presence of KIO4, between the quinoneimine form of PAP and the deprotonated form of 2-isopropoxyphenol, obtained by the alkaline hydrolysis of propoxur, to provide an indophenol dye which absorbs at 600 nm. The analysis is carried out in a flow system and, after the measurement step, the waste, the reaction product and the unreacted derivatising agent is detoxified in a UV-irradiated coil placed after the measurement flow-cell and after mixing the waste with a TiO2(anatase) catalyst slurry, which can be reu…

AnataseChromatographymedicine.diagnostic_testPropoxurAlkaline hydrolysis (body disposal)BiochemistryAnalytical ChemistryCatalysischemistry.chemical_compoundchemistrySpectrophotometrySlurrymedicineEnvironmental ChemistryIndophenolDerivatizationSpectroscopyAnalytica Chimica Acta
researchProduct

Determination of fatty alcohol ethoxylates and alkylether sulfates by anionic exchange separation, derivatization with a cyclic anhydride and liquid …

2011

A method for the separation, characterization and determination of fatty alcohol ethoxylates (FAE) and alkylether sulfates (AES) in industrial and environmental samples is described. Separation of the two surfactant classes was achieved in a 50:50 methanol-water medium by retaining AES on a strong anionic exchanger (SAX) whereas most FAE were eluted. After washing the SAX cartridges to remove cations, the residual hydrophobic FAE were eluted by increasing methanol to 80%. Finally, AES were eluted using 80:20 and 95:5 methanol-concentrated aqueous HCl mixtures. Methanol and water were removed from the FAE and AES fractions, and the residues were dissolved in 1,4-dioxane. In this medium, este…

AnionsEthylene OxideFatty alcoholBiochemistryAnalytical ChemistryDioxanesSurface-Active Agentschemistry.chemical_compoundAcetic acidSeawaterDerivatizationChromatography High Pressure LiquidPhthalic anhydrideAqueous solutionChromatographyEsterificationSulfatesElutionOrganic ChemistryExtraction (chemistry)General MedicineChromatography Ion ExchangechemistryMethanolFatty AlcoholsDibenzoxepinsJournal of Chromatography A
researchProduct

Determination of non-ionic and anionic surfactants in industrial products by separation on a weak ion-exchanger, derivatization and liquid chromatogr…

2013

Abstract A method for the determination of priority surfactants, including fatty alcohol ethoxylates (FAE), alkylether sulfates (AES) and linear alkylbenzene sulfonates (LAS) is described. The samples were diluted with 50% methanol at pH 4 prior to solid-phase extraction on a weak anionic exchanger (WAX). The AES and LAS surfactant classes were retained, whereas the non-ionic components, including most FAE oligomers were eluted. After washing the WAX cartridge to remove cations, the remaining hydrophobic FAE oligomers were eluted using hot 80% methanol at pH 4 (at ca. 50 °C). These two eluates were combined to constitute the non-ionic fraction. Then, AES and LAS were eluted using 80% MeOH w…

AnionsWaxPhthalic anhydrideChromatographyEsterificationLinear alkylbenzeneElutionOrganic ChemistryExtraction (chemistry)Fatty alcoholGeneral MedicineHydrogen-Ion ConcentrationChromatography Ion ExchangeBiochemistryAnalytical ChemistrySurface-Active Agentschemistry.chemical_compoundchemistryvisual_artvisual_art.visual_art_mediumMethanolDerivatizationChromatography High Pressure LiquidJournal of Chromatography A
researchProduct

Molecular Characterization of White Wines Antioxidant Metabolome by Ultra High Performance Liquid Chromatography High-Resolution Mass Spectrometry

2020

International audience; The knowledge about the molecular fraction contributing to white wines oxidative stability is still poorly understood. However, the role of S- and N-containing compounds, like glutathione and other peptides, as a source of reductant in many oxidation reactions, and acting against heavy metals toxicity, or lipid and polyphenol oxidation as ROS-scavenger is today very well established. In that respect, the aim of the present study is to introduce an original analytical tool for the direct determination of the available nucleophilic compounds in white wine under acidic pH conditions. One step derivatization of nucleophiles has been realized directly in wines using 4-met…

AntioxidantUHPLC-QqTOF-MSPhysiologymedicine.medical_treatmentClinical BiochemistrynucleophilesMass spectrometry01 natural sciencesBiochemistryArticlechemistry.chemical_compound0404 agricultural biotechnologymedicineMetabolomeDerivatizationuntargeted analysisMolecular BiologyMETLINthiolsWineChromatographyChardonnay wine oxidationChemistry010401 analytical chemistrylcsh:RM1-950food and beverages04 agricultural and veterinary sciencesCell Biology040401 food science0104 chemical sciencesQuinonelcsh:Therapeutics. PharmacologyPolyphenolpeptides[SDV.AEN]Life Sciences [q-bio]/Food and Nutrition
researchProduct

Determination of alkylamines in atmospheric aerosol particles: a comparison of gas chromatography–mass spectrometry and ion chromatography approaches

2014

Abstract. In recent years low molecular weight alkylamines have been recognized to play an important role in particle formation and growth in the lower atmosphere. However, major uncertainties are associated with their atmospheric processes, sources and sinks, mostly due to the lack of ambient measurements and the difficulties in accurate quantification of alkylamines at trace level. In this study, we present the evaluation and optimization of two analytical approaches, i.e., gas chromatography–mass spectrometry (GC-MS) and ion chromatography (IC), for the determination of alkylamines in aerosol particles. Alkylamines were converted to carbamates through derivatization with isobutyl chlorof…

Atmospheric ScienceIon chromatographyAnalytical chemistryMass spectrometrychemistryammoniachemistry.chemical_compoundColumn chromatographyaliphatic-aminesderivatizationlcsh:TA170-171phaseDerivatizationDetection limitChromatographyChemistrylcsh:TA715-787lcsh:Earthwork. Foundationsaromatic-aminesAerosollcsh:Environmental engineering13. Climate actionReagentnanoparticleschemical-compositionGas chromatography–mass spectrometryseasonal-variationsecondary organic aerosol
researchProduct

Automated pre-column derivatization of amines in biological samples with dansyl chloride and with or without post-column chemiluminescence formation …

1999

On-line automation of two different liquid chromatographic procedures, a pre-column derivatization system and a pre- and post-column system, in order to generate chemiluminescence is reported. Dansyl chloride (Dns-Cl) was used as a pre-column reagent to form fluorophores and bis(2,4,6-trichlorophenyl) oxalate (TCPO) and hydrogen peroxide (H2O2) as a post-column reagent to generate chemiluminescence. This procedure is based on the employment of a primary column packed with C18 material inserted in a multi-dimensional assembly for sample clean-up and derivatization with Dns-Cl. The dansyl derivatives formed are transferred and separated in a LiChrospher 100 RP18 analytical column (125 x 4 mm …

BiochemistryAnalytical Chemistrylaw.inventionMethamphetaminechemistry.chemical_compoundColumn chromatographylawElectrochemistryEnvironmental ChemistryHumansTCPOAminesHydrogen peroxideDerivatizationSpectroscopyChemiluminescenceDansyl CompoundsOxalatesChromatographyChemistryDansyl chlorideAmphetamineReagentLuminescent MeasurementsIndicators and ReagentsQuantitative analysis (chemistry)Chromatography LiquidThe Analyst
researchProduct