Search results for "Design"

showing 10 items of 5885 documents

Optical gain, spontaneous and stimulated emission of surface plasmon polaritons in confined plasmonic waveguide

2010

International audience; We develop a theoretical model to compute the local density of states in a confined plasmonic waveguide. Based on this model, we derive a simple formula with a clear physical interpretation for the lifetime modification of emitters embedded in the waveguide. The gain distribution within the active medium is then computed following the formalism developed in a recent work [Phys. Rev. B 78, 161401 (2008)], by taking rigorously into account the pump irradiance and emitters lifetime modifications in the system. We finally apply this formalism to describe gain–assisted propagation in a dielectric–loaded surface plasmon polariton waveguide.

Amplified spontaneous emissionWaveguide (electromagnetism)Optical amplifiersLightPhysics::Optics02 engineering and technologySurface plasmons01 natural sciences010309 opticsOptics0103 physical sciencesScattering RadiationComputer SimulationSpontaneous emissionStimulated emission[SPI.NANO]Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsOptical amplifierPhysicsQuantum electrodynamicsbusiness.industrySurface plasmonOptical DevicesEquipment DesignModels TheoreticalSurface Plasmon ResonanceWeights and Measures021001 nanoscience & nanotechnologySurface plasmon polaritonAtomic and Molecular Physics and OpticsComputer-Aided DesignOptoelectronics[ SPI.NANO ] Engineering Sciences [physics]/Micro and nanotechnologies/MicroelectronicsQuantum electrodynamics.0210 nano-technologybusiness(240.6680) Surface plasmons; (230.4480) Optical amplifiers; (020.5580) Quantum electrodynamics.Localized surface plasmon
researchProduct

Topological Approach to Analgesia

1994

AnalgesicsTheoretical computer scienceChemical PhenomenaMolecular StructureChemistry PhysicalComputer sciencebusiness.industryGeneral ChemistryComputer Science ApplicationsStructure-Activity RelationshipText miningModels ChemicalComputational Theory and MathematicsDrug DesignAnimalsbusinessInformation SystemsJournal of Chemical Information and Computer Sciences
researchProduct

ECO-FRIENDLY MATERIALS FOR THE ENERGY RETROFIT OF EXISTING BUILDINGS

2015

Today is widely recognized that the main cause of CO2 production and of non-renewable energy consumptions in Europe is due to the building field. For this reason, to improve the energy performance of existing houses through an energy retrofit action (adapting their performances to those required by regulations) is an important strategy to reduce energy consumptions since they are much more than new ones, also representing an economic opportunity. In particular, an important approach in the reducing energy needs consists in the thermal insulation of the envelope, through the application of innovative technologies and materials. The paper will present the result of a research about the possib…

Analisi Costi-benefici RetrofitCost-benefits analysis Energy retrofit Housing Insulating materials Sustainable design.Settore ICAR/10 - Architettura TecnicaAbitare Materiali isolanti Progettazione Sostenibile
researchProduct

Oval fiber posts do not improve adaptation to oval-shaped canal walls.

2011

Abstract Introduction Oval fiber posts attempt to provide better adaptation to root canals. The hypothesis of this study was that there are no differences in adaptation of oval and circular fiber posts to canal walls. Methods Posts were inserted in 20 canals; 10 were oval, and 10 were circular. The posts were cemented with composite cement. Coronal, middle, and apical sections were observed through a microscope. The space occupied by the post and the maximum distance between it and the canal wall were calculated. The 2 groups were compared with analysis of variance. In all the analyses the level of significance was set at P Results The proportion of space occupied by the post showed no sign…

Analysis of Variancedigestive oral and skin physiologyAnatomyDental Marginal Adaptationdigestive systemstomatognathic systemDental Prosthesis DesignHumansCanal wallBicuspidGlassDental Pulp CavityFiber postsGeneral DentistryCementationGeologyPost and Core TechniqueJournal of endodontics
researchProduct

Computer simulations for bioequivalence trials: Selection of analyte in BCS class II and IV drugs with first-pass metabolism, two metabolic pathways …

2018

A semi-physiological two compartment pharmacokinetic model with two active metabolites (primary (PM) and secondary metabolites (SM)) with saturable and non-saturable pre-systemic efflux transporter, intestinal and hepatic metabolism has been developed. The aim of this work is to explore in several scenarios which analyte (parent drug or any of the metabolites) is the most sensitive to changes in drug product performance (i.e. differences in in vivo dissolution) and to make recommendations based on the simulations outcome. A total of 128 scenarios (2 Biopharmaceutics Classification System (BCS) drug types, 2 levels of KM Pgp, in 4 metabolic scenarios at 2 dose levels in 4 quality levels of t…

AnalyteCmaxPharmaceutical ScienceAdministration Oral02 engineering and technologyEquivalence Trials as TopicPharmacologyBioequivalence030226 pharmacology & pharmacyModels Biological03 medical and health sciencesFirst pass effect0302 clinical medicinePharmacokineticsHumansComputer SimulationPharmacokineticsIntestinal MucosaBiotransformationChemistryMembrane Transport Proteins021001 nanoscience & nanotechnologyBiopharmaceutics Classification SystemNONMEMNonlinear DynamicsPharmaceutical PreparationsSolubilityTherapeutic EquivalencyResearch DesignArea Under CurveLinear Models0210 nano-technologyMonte Carlo MethodDrug metabolismEuropean journal of pharmaceutical sciences : official journal of the European Federation for Pharmaceutical Sciences
researchProduct

Multiplexed plasmon sensor for rapid label-free analyte detection.

2013

Efficient and cost-effective multiplexed detection schemes for proteins in small liquid samples would bring drastic advances to fields like disease detection or water quality monitoring. We present a novel multiplexed sensor with randomly deposited aptamer functionalized gold nanorods. The spectral position of plasmon resonances of individual nanorods, monitored by dark-field spectroscopy, respond specifically to different proteins. We demonstrate nanomolar sensitivity, sensor recycling, and the potential to upscale to hundreds or thousands of targets.

AnalyteMaterials scienceAptamerNanophotonicsProtein Array AnalysisBioengineeringNanotechnology02 engineering and technologyBiosensing Techniques010402 general chemistry01 natural sciencesMultiplexingNanotechnologyGeneral Materials ScienceSpectroscopyPlasmonLabel freeStaining and LabelingMechanical EngineeringProteinsGeneral ChemistryEquipment DesignSurface Plasmon Resonance021001 nanoscience & nanotechnologyCondensed Matter Physics0104 chemical sciencesEquipment Failure AnalysisNanorod0210 nano-technologyNano letters
researchProduct

Highly Sensitive Detection of Naphthalene in Solvent Vapor Using a Functionalized PBG Refractive Index Sensor

2012

We report an optical refractive index sensor system based on a planar Bragg grating which is functionalized by substituted γ-cyclodextrin to determine low concentrations of naphthalene in solvent vapor. The sensor system exhibits a quasi-instantaneous shift of the Bragg wavelength and is therefore capable for online detection. The overall shift of the Bragg wavelength reveals a linear relationship to the analyte concentration with a gradient of 12.5 ± 1.5 pm/ppm. Due to the spectral resolution and repeatability of the interrogation system, this corresponds to acquisition steps of 80 ppb. Taking into account the experimentally detected signal noise a minimum detection limit of 0.48 ± 0.05 pp…

AnalyteMaterials sciencegas detection; optical sensor; Bragg grating; cyclodextrin; aromatic hydrocarbonsTransducersaromatic hydrocarbonsAnalytical chemistryPhysics::OpticsNaphthaleneslcsh:Chemical technologyBiochemistryNoise (electronics)gas detectionArticleAnalytical ChemistryFiber Bragg gratinglcsh:TP1-1185Electrical and Electronic Engineeringoptical sensorInstrumentationDetection limitCyclodextrinsEquipment DesignAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryWavelengthTransducercyclodextrinSolventsBragg gratingGasesRefractometryRefractive indexSensors
researchProduct

Strategies for the enantiomeric determination of amphetamine and related compounds by liquid chromatography.

2002

This paper summarizes recent research on the stereospecific analysis of amphetamine, its analogs and metabolites, by liquid chromatography. The different methods proposed have been evaluated and compared in terms of resolution power, time of analysis, sensitivity, or potential for automation. Chiral derivatization, followed by separation of the diastereomers formed in achiral chromatographic systems, is still the method preferred for the analysis of amphetamines at trace levels, as derivatization also improves analyte detectability. This is the method of choice for the enantiomeric analysis of amphetamines at the low concentrations typically encountered in biological samples. In recent year…

AnalyteResolution (mass spectrometry)medicine.drug_classBiophysicsBiochemistrySensitivity and Specificitychemistry.chemical_compoundIsomerismmedicineHumansEphedrineDerivatizationAmphetamineChromatography High Pressure LiquidChromatographyStaining and LabelingIllicit DrugsAmphetaminesDiastereomerReproducibility of ResultsDesigner drugSubstance Abuse DetectionchemistryModels ChemicalEnantiomermedicine.drugChromatography LiquidJournal of biochemical and biophysical methods
researchProduct

Comparison of the solid-phase extraction efficiency of a bounded and an included cyclodextrin-silica microporous composite for polycyclic aromatic hy…

2016

Solid-phase extraction is one of the most important techniques for sample purification and concentration. A wide variety of solid phases have been used for sample preparation over time. In this work, the efficiency of a new kind of solid-phase extraction adsorbent, which is a microporous material made from modified cyclodextrin bounded to a silica network, is evaluated through an analytical method which combines solid-phase extraction with high-performance liquid chromatography to determine polycyclic aromatic hydrocarbons in water samples. Several parameters that affected the analytes recovery, such as the amount of solid phase, the nature and volume of the eluent or the sample volume and …

Analytical chemistry010501 environmental sciences01 natural sciencesHigh-performance liquid chromatographyAnalytical ChemistryAdsorptionColumn chromatographyLimit of DetectionPhase (matter)Sample preparationSolid phase extractionPolycyclic Aromatic HydrocarbonsChromatography High Pressure Liquid0105 earth and related environmental sciencesCyclodextrinsChromatographyChemistry010401 analytical chemistryExtraction (chemistry)Solid Phase ExtractionWaterMicroporous materialEquipment DesignSilicon Dioxide0104 chemical sciencesAdsorptionPorosityWater Pollutants ChemicalTalanta
researchProduct

Use of radiation sources with mercury isotopes for real-time highly sensitive and selective benzene determination in air and natural gas by different…

2015

A new analytical portable system is proposed for the direct determination of benzene vapor in the ambient air and natural gas, using differential absorption spectrometry with the direct Zeeman effect and innovative radiation sources: capillary mercury lamps with different isotopic compositions ((196)Hg, (198)Hg, (202)Hg, (204)Hg, and natural isotopic mixture). Resonance emission of mercury at a wavelength of 254 nm is used as probing radiation. The differential cross section of benzene absorption in dependence on wavelength is determined by scanning of magnetic field. It is found that the sensitivity of benzene detection is enhanced three times using lamp with the mercury isotope (204)Hg in…

Analytical chemistrychemistry.chemical_elementNatural GasMass spectrometryBiochemistryAnalytical Chemistrychemistry.chemical_compoundsymbols.namesakeLimit of DetectionEnvironmental ChemistryBenzeneSpectroscopyDetection limitAir PollutantsZeeman effectSpectrometerSpectrophotometry AtomicAbsorption RadiationBenzeneEquipment DesignTolueneMercury (element)WavelengthMercury IsotopeschemistrysymbolsEnvironmental MonitoringAnalytica chimica acta
researchProduct