Search results for "Detection limit"

showing 10 items of 810 documents

Development of a real-time PCR assay for detection and quantification of enterotoxigenic members of Bacillus cereus group in food samples

2009

A highly sensitive real-time PCR (qPCR) procedure, targeting the phosphatidylcholine-specific phospholipase C gene (pc-plc), was developed for specific detection and quantification of strains belonging to Bacillus cereus group. The target region was selected based on the enterotoxigenic profiles of 75 Bacillus strains. The inclusivity and exclusivity of the RTi-PCR assay were assessed with 59 isolates of the B. cereus group, 16 other Bacillus spp., and 4 non-Bacillus strains. The assay was also used to construct calibration curves for different food matrices, and it had a wide quantification range of 6 log units using both serial dilutions of purified DNA and calibrated cell suspensions of …

DNA BacterialSerial dilutionEggsMolecular Sequence DataColony Count MicrobialBacillus cereusFood ContaminationPolymerase Chain ReactionSensitivity and SpecificityMicrobiologyMicrobiologyEnterotoxinsBacillus cereusSpecies SpecificityHumansFood microbiologyDetection limitBacillus (shape)ChromatographybiologyfungiInfant NewbornInfantReproducibility of ResultsSequence Analysis DNAGeneral Medicinebiology.organism_classificationBacillalesInfant FormulaCereusCalibrationFood MicrobiologyFood ScienceFood contaminantInternational Journal of Food Microbiology
researchProduct

Supported liquid membrane extraction with single hollow fiber for the analysis of fluoroquinolones from environmental surface water samples

2010

Abstract In this work, the simple analytical method for the determination of four fluoroquinolone antibiotics: ciprofloxacin, enrofloxacin, norfloxacin and danofloxacin, in environmental surface water samples is described. Sample pretreatment step was performed by the application of a technique based on supported liquid membrane extraction with the configuration of single hollow fiber (HF-SLM). The HPLC system with diode array detection was used for final analysis of studied analytes. Various parameters affecting the extraction efficiency during HF-SLM enrichment, such as type of membrane diluent, pH of donor (sample) and acceptor phases, as well as an enrichment time and salt content of sa…

DanofloxacinAnalytical chemistrySodium ChlorideBiochemistryHigh-performance liquid chromatographyDiluentSensitivity and SpecificityAnalytical ChemistryRiversmedicinehollow fiberenvironmental samplesSample preparationfluoroquinolonesChromatography High Pressure LiquidDetection limitChromatographysample preparationChemistryOrganic ChemistryExtraction (chemistry)Reproducibility of ResultsMembranes ArtificialGeneral MedicineHydrogen-Ion ConcentrationAnti-Bacterial Agentssupported liquid membrane extractionWater treatmentHydrochloric AcidEnrichment factorWater Pollutants Chemicalmedicine.drugJournal of Chromatography A
researchProduct

Ultrahigh-Resolution Mass Spectrometry in Real Time: Atmospheric Pressure Chemical Ionization Orbitrap Mass Spectrometry of Atmospheric Organic Aeros…

2018

The accurate and precise mass spectrometric measurement of organic compounds in atmospheric aerosol particles is a challenging task that requires analytical developments and adaptations of existing techniques for the atmospheric application. Here we describe the development and characterization of an atmospheric pressure chemical ionization Orbitrap mass spectrometer (APCI-Orbitrap-MS) for the measurement of organic aerosol in real time. APCI is a well-known ionization technique, featuring minimal fragmentation and matrix dependencies, and allows rapid alternation between the positive and negative ionization mode. As a proof of principle, we report ambient organic aerosol composition in rea…

Detection limit010504 meteorology & atmospheric sciencesChemistryAnalytical chemistryAtmospheric-pressure chemical ionization010501 environmental sciencesMass spectrometryOrbitrap01 natural sciencesAnalytical Chemistrylaw.inventionAerosolIonFragmentation (mass spectrometry)lawIonization0105 earth and related environmental sciencesAnalytical Chemistry
researchProduct

Rapid evaluation of ammonium in different rain events minimizing needed volume by a cost-effective and sustainable PDMS supported solid sensor.

2020

Abstract The presence of ammonium ion in rainwater is due to atmospheric processes which involve its scavenging from gas phase and particulate matter. The fractionated samplings of rainwater can provide information about these processes and their potential sources. However, only a low sample volume may be available, which constrained the analysis in general and more particularly in situ mode. For minimizing this limitation, this work proposes a polydimethylsiloxane (PDMS)-salicylate sensor that produces a color change. The embedding of solid reagents into PDMS was optimized. Good analytical characteristics (analysis time of 10 min, sample volume of 500 μL, limit of detection 0.03 μgmL−1) we…

Detection limit010504 meteorology & atmospheric sciencesHealth Toxicology and MutagenesisCost-Benefit AnalysisRainEnvironmental engineeringGeneral Medicine010501 environmental sciencesParticulatesToxicologyRainout01 natural sciencesPollutionIon selective electrodeRainwater harvestingchemistry.chemical_compoundchemistryVolume (thermodynamics)SpainAmmonium CompoundsCarbon footprintEnvironmental scienceAmmoniumDimethylpolysiloxanes0105 earth and related environmental sciencesEnvironmental pollution (Barking, Essex : 1987)
researchProduct

Flow injection near-infrared determination of ethanol in chloroform

1995

A simple and direct flow injection (FIA) procedure has been developed for the determination of the stabilizing agent ethanol in chloroform samples. The procedure is based on the use of the absorbance band of ethanol in the near-infrared (NIR) region at 2272 nm, measured in front of a reference sample of chloroform stabilized with amylene. The method developed provides a limit of detection of 0.0045% (v/v) and a dynamic range until 10% (v/v) with a typical variation coefficient of 0.4% for six independent analysis of a real sample containing approximately 1% (v/v) of ethanol. The sample injection frequency allowed by the method is 78 h−1.

Detection limitAbsorbancechemistry.chemical_compoundEthanolChloroformchemistryReference sampleNear-infrared spectroscopyAnalytical chemistryAlcoholBiochemistryDirect flowFresenius' Journal of Analytical Chemistry
researchProduct

Comparative study of reflectance cells for PLS-FTIR determination of sugars in soft drinks

1998

A comparative study has been carried out between a horizontal Attenuated Total Reflectance (h-ATR) cell and a Cylindrical Internal Reflection (CIR) cell (CIRCLE cell). Both cells were employed for the determination of glucose, fructose, sucrose and total sugar in soft drinks and fruit juices using absorbance measurements at two resolution values (4 and 8 cm–1). Data were processed by Partial Least Squares regression (PLS). Using a resolution of 4 cm–1, mean relative errors of prediction from 0.6% to 1.3% were obtained using the horizontal-ATR and from 0.6% to 2.8% using the CIRCLE cell resulting in a limit of detection from 0.03% in the case of sucrose to 0.21% for total sugar for the h-ATR…

Detection limitAbsorbancechemistry.chemical_compoundSucrosechemistryAttenuated total reflectionPartial least squares regressionAnalytical chemistryFructoseSugarBiochemistryQuantitative analysis (chemistry)Fresenius' Journal of Analytical Chemistry
researchProduct

Optical recognition and removal of Hg(II) using a new self-chemosensor based on a modified amino-functionalized Al-MOF

2017

Abstract We developed a simple self-chemical optical sensor for the monitoring and removal of ultra-trace levels of Hg(II) from aqueous media. The development of this sensor was based on the covalent attachment of amino-functionalized aluminum-based MOF particles with ninhydrin. The new sensor is densely coated with a chelating ligand to permit an ultra-fast, selective, pH-dependent visualization for removal of Hg(II) with detection limit (LOD∼0.494 μg L−1). Monitoring was accomplished via both a colorimetric signal visible to the naked eye as well as UV–vis absorption spectroscopy. Digital image-based colorimetric analysis has also used as a semi-quantitative analysis for determination the…

Detection limitAbsorption spectroscopyMetals and AlloysAnalytical chemistry02 engineering and technology010402 general chemistry021001 nanoscience & nanotechnologyCondensed Matter Physics01 natural sciences0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialschemistry.chemical_compoundchemistryCovalent bondNinhydrinMaterials ChemistryChelationNaked eyeElectrical and Electronic Engineering0210 nano-technologyColorimetric analysisInstrumentationSilver oxideNuclear chemistrySensors and Actuators B: Chemical
researchProduct

New optical paper sensor for in situ measurement of hydrogen sulphide in waters and atmospheres

2016

A novel and low-cost colorimetric sensor for the determination of hydrogen sulphide in environmental samples has been developed. This sensor is based on the immobilization of the reagent N,N-Dimethyl-p-phenylenediamine and FeCl3 in paper support, in which the H2S is adsorbed in order to give rise to the formation of methylene blue as reaction product. The sensor has been applied to determine H2S in water and air samples. Two different sampling systems for H2S caption from the air have been assayed: active and passive sampling. The analytical properties of the different systems have been obtained and compared. The analytical signals, corresponding to the methylene blue, have been obtained me…

Detection limitAccuracy and precision010401 analytical chemistryAnalytical chemistry02 engineering and technology021001 nanoscience & nanotechnology01 natural sciencesSignal0104 chemical sciencesAnalytical ChemistryAbsorbancechemistry.chemical_compoundchemistrySampling (signal processing)ReagentNaked eye0210 nano-technologyDerivatizationTalanta
researchProduct

A new flow cell design for chemiluminiscence analysis.

2001

The present study proposes a new flow cell called a bundle cell for chemiluminescence analysis. The results obtained were compared with those achieved by manual and automated batch procedures and flow manifolds with different cells: an common quartz flow cell, a helix cell and the most used spiral cell. Figures of merit such as limit of detection, sensitivity, accuracy and precision for the Cr(III) determination were established with light emission produced by catalysed Cr(III) luminol oxidation by hydrogen peroxide in a basic aqueous solution. An improvement in sensitivity about 50% as compared with the spiral cell and even larger with respect to the other flow cells tested was observed. T…

Detection limitAccuracy and precisionAqueous solutionChemistryAnalytical chemistryMineralogyAnalytical ChemistryLuminollaw.inventionchemistry.chemical_compoundFlow (mathematics)lawBatch processingLight emissionChemiluminescenceTalanta
researchProduct

Addition of thiourea and hydrochloric acid: Accurate nanogram level analysis of mercury in humic-rich natural waters by inductively coupled plasma ma…

2020

Abstract An analytical method was developed for the direct determination of total mercury in natural waters at low ng L−1 level by inductively coupled plasma mass spectrometry (ICP-MS). The presented method overcomes previously observed problems relating to poor spike recoveries by adding 0.12% thiourea in addition to 3% HCl to all samples and standards. The sample preparation is fast and easy to perform by the developed method since it requires only the addition of HCl and thiourea to the water samples. A very low instrument detection limit (0.4 ng L−1) was obtained without time-consuming preconcentration procedures. The accuracy and precision of the developed method were found excellent b…

Detection limitAccuracy and precisionChromatographyChemistry010401 analytical chemistrychemistry.chemical_elementHydrochloric acid02 engineering and technology021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesAnalytical ChemistryMercury (element)chemistry.chemical_compoundThioureaSample preparation0210 nano-technologyMethylmercuryInductively coupled plasma mass spectrometryTalanta
researchProduct