Search results for "Detection limit"
showing 10 items of 810 documents
Flow spectrophotometric determination of ammonium ion
1999
Abstract A flow procedure is proposed for the determination of ammonium ion. The sample in basic medium is forced through a solid-phase reactor containing immobilized AgCl on polymeric pearl beads. The released Ag + , complexed with the ammonia, gives a blue ternary complex with the aid of bromopyrogallol red and 1,10-phenanthroline which is spectrophotometrically monitored at 636 nm. The calibration graph is linear over the range 1–20 μg ml −1 ammonium ion, detection limit ( s / n = 3) 0.35 μg ml −1 and relative standard deviation (slope) 1.9 % ( n = 7). The sample throughput is 48 h −1 . The influence of foreign compounds is studied and the procedure is applied to ammonium ion determi…
Contribution to the adsorption voltammetric determination of manganese
1994
The adsorption voltammetric determination of Mn(II) with Bromopyrogallol Red (BPR) and Mordant Red 19 (MDR) has been investigated using a hanging drop mercury electrode. In NH3/NH4Cl solution, ligands and Mn(II) complexes give well separated voltammetric peaks after enrichment onto the electrode. The conditions for determining manganese by adsorption voltammetry with these reagents have been investigated in detail, as has the influence of foreign ions on the determination. The detection limits are 4·10−10 mol/L Mn for BPR and 8·10−10 mol/L Mn for MDR, respectively.
Urine polyamines determination using dansyl chloride derivatization in solid-phase extraction cartridges and HPLC
1999
The derivatization of biogenic amines such as putrescine, cadaverine, spermidine and spermine with dansyl chloride in solid phase extraction cartridges is described. Different types of filling materials were tested in order to have the highest retention of the different analytes. The best results were obtained by using C18 cartridges. The optimal conditions were: amine solution buffered at pH 12, 2 mM dansyl chloride (acetone-bicarbonate solution 20 mM (pH 9-9.5), 2 + 3 v/v) as reagent concentration, room temperature and 30 min reaction time. The developed procedure was applied to the determination of these polyamines in urine samples from healthy controls and cancer patients using HPLC wit…
Determination of aluminum at the parts per billion level by solvent extraction and flame atomic emission spectrometry
1991
A new method for the determination of aluminum at the parts per billion level, by N 2 O/ C 2 H 2 flame emission spectrometry with prior solvent extraction with acetylacetone or 8-hydroxyquinoline in 4-methylpentan-2-one, has been performed. The influence of extraction conditions and instrumental parameters on the sensitivity, precision, and dynamic range of the emission calibration curves have been studied. The limit of detection is between 5 and 10 ppb for both ligands, the variation coefficient being 0.2 and 3% at levels of 75 and 25 ppb, respectively. The method has been applied to the determination of Al in water and the results obtained are compared with those found by the standard add…
Capillary electrophoresis for the determination of pesticide residues
2003
Capillary electrophoresis (CE) is becoming an advantageous tool for determining pesticide residues in environmental matrices because of its simplicity and high separation efficiency. However, inadequate limits of detection (LODs) and a lack of selective detectors limit the technique. The present review gives an overview of current developments in off-column and on-column approaches to trace enrichment in analysing real samples, and summarises the determination of pesticides residues by conventional CE as well as by the emerging techniques, such as CE-mass spectrometry (MS). The usefulness of these approaches in environmental applications is documented.
Separation of plutonium and neptunium species by capillary electrophoresis-inductively coupled plasma-mass spectrometry and application to natural gr…
2003
Capillary electrophoresis (CE) was coupled to ICPMS in order to combine the good performance of this separation technique with the high sensitivity of the ICPMS for the analysis of plutonium and neptunium oxidation states. The combination of a fused-silica capillary with a MicroMist AR 30-I-FM02 nebulizer and a Cinnabar small-volume cyclonic spray chamber yielded the best separation results. With this setup, it was possible to separate a model element mixture containing neptunium (NpO2(+)), uranium (UO2(2+)), lanthanum (La3+), and thorium (Th4+) in 1 M acetic acid. The same conditions were also suitable for the separation of various oxidation states of plutonium and neptunium in different a…
Preliminary Results on the Use of Leather Chrome Shavings for Air Passive Sampling
2012
A new passive sampler based on low-density polyethylene (LDPE) layflat tube filled with chrome shavings from tannery waste residues was evaluated to determine volatile organic compounds (VOCs) in indoor and outdoor areas. VOCs were directly determined by head space-gas chromatography-mass spectrometry (HS-GC-MS) without any pretreatment of the sampler and avoiding the use of solvents. Limit of detection values ranging from 20 to 75 ng sampler−1and good repeatability values were obtained for VOCs under study with relative standard deviation values from 2.8 to 9.6% except for carbon disulfide for which it was 22.5%. The effect of the amount of chrome shavings per sampler was studied and resul…
Development and characterization of a thermal inkjet-based aerosol generator for micro-volume sample introduction in analytical atomic spectrometry
2011
A novel system for the introduction of liquid samples into analytical plasmas for atomic spectrometric analysis is presented in this manuscript for the first time. The proposed “drop-on-demand” (DOD) aerosol generator is based on the use of a modified thermal inkjet cartridge. This system employs a lab-built microcontroller, which allows accessing all parameters important for driving the dosing cartridge for the generation of pL-droplets from sample volumes in the μL range. The droplet generation frequency, thus the resulting liquid flow rate, is variable over a wide range from the generation of isolated droplets up to a theoretical flow rate of approximately 2 mL min−1, with parallel opera…
Study of passive sampling of polycyclic aromatic hydrocarbons in gas phase using Amberlite XAD resins as filling materials of semipermeable membranes
2013
Abstract In this work, a study was performed to evaluate the use of Amberlite XAD resins (XAD-2, XAD-4 and XAD-16), for the first time, as filling materials for low-density polyethylene membranes, which will be inserted as passive samplers for polycyclic aromatic hydrocarbons (PAHs) in gas phase. The use of samplers deployed for 48 h evidenced a relative capability to retain the compounds under study. A detailed study was performed to evaluate the recovery of analytes from the sampler through microwave-assisted extraction by using acetonitrile. A clean-up step using alumina-C18 cartridges was necessary before determination of the PAHs by high performance liquid chromatography with fluoresce…
Flow injection flame atomic absorption analysis of Fe and Mn in cement samples
1993
A new procedure has been developed for the determination of Fe and Mn in cements. It consists in dispersing 50 mg of the solid sample in 25 ml of 0.15 mol/l HNO3 and 0.12 mol/l HCl solution. Acid slurries are heated at 50°C for 10 min and then different volumes of the slurry are injected into a water carrier stream. This previous acid treatment leaches the elements to be determined and permits the use of acid solutions as standards. For the Mn determination, the use of a single line flow injection manifold provides a limit of detection of 0.03 mgl−1 and a dynamic range up to 6 mgl−1. For the determination of Fe, the on-line dispersion of samples, using a well stirred mixing chamber, increas…