Search results for "Detection limit"

showing 10 items of 810 documents

Selective determination of trimethylamine in air by liquid chromatography using solid phase extraction cartridges for sampling.

2004

Abstract The selective determination of trimethylamine (TMA) in air by liquid chromatography is reported. Sampling is effected by flushing air through C18-packed solid-phase extraction (SPE) cartridges at a flow rate of 15 mL/min for 15 min. Next, TMA is desorbed from the cartridges and injected into the chromatographic system. The analyte is then selectively retained on a precolumn ( 20 mm ×2.1 mm i.d., packed with 30 μm, Hypersil C18 phase), and derivatized on-line by injecting 9-fluorenylmethyl chloroformate (FMOC). Finally, the TMA-FMOC derivative is transferred to the analytical column ( 125 mm ×4 mm i.d., LiChrospher 100 RP18, 5 μm), and monitored at 262 nm. The method was applied to …

AnalyteAnalytical chemistryTrimethylamineChloroformateAir Pollutants OccupationalBuffersBiochemistryAnalytical ChemistryCartridgechemistry.chemical_compoundMethylaminesBoric AcidsSolid phase extractionDetection limitReproducibilityChromatographyOrganic ChemistryExtraction (chemistry)Reproducibility of ResultsGeneral MedicineReference StandardsSolutionschemistryCalibrationIndicators and ReagentsSpectrophotometry UltravioletChromatography Liquid
researchProduct

Tuning the selectivity of molecularly imprinted polymer extraction of arylcyclohexylamines: From class-selective to specific

2020

Abstract A molecularly imprinted polymer (MIP) has been prepared in presence of 3-hydroxy phencyclidine (3-OH PCP) as template by bulk polymerization using N,N-dimethylformamide, as porogenic solvent, for the selective solid-phase extraction (SPE) of arylcyclohexylamines from oral fluids. Experimental variables of the extraction procedure have been studied in order to increase both, extraction recovery of 3-OH PCP, used as model analyte, and imprinting factor. By modifying the composition of the washing solvent, the selectivity of the MIP extraction procedure can be tuned, moving from an arylcyclohexylamine selective method to a 3-OH PCP specific method. The applicability of the synthesized…

AnalyteArylcyclohexylamineBulk polymerizationSurface PropertiesIon-mobility spectrometry02 engineering and technology01 natural sciencesBiochemistryPolymerizationAnalytical ChemistryMolecularly Imprinted PolymersIon Mobility SpectrometrymedicineEnvironmental ChemistryParticle SizeSpectroscopyDetection limitCyclohexylaminesChromatographyMolecular StructureChemistry010401 analytical chemistryMolecularly imprinted polymer021001 nanoscience & nanotechnology0104 chemical sciencesSolvent0210 nano-technologySelectivitymedicine.drugAnalytica Chimica Acta
researchProduct

Synergistic combination of polyamide-coated paper-based sorptive phase for the extraction of antibiotics in saliva.

2021

Abstract The development of analytical methods that allow the simultaneous determination of a wide range of analytes with different properties is one of the focuses of attention in Analytical Chemistry. This work describes a proof-of-concept of the synergistic extraction of a planar paper-based sorptive phase modified with a polyamide such as nylon. This as-prepared sorptive phase enables the extraction of six penicillin-derived antibiotics of different polarity from human saliva samples in the same analysis, since the analytes either interact with the paper or with the nylon. The synthesis of the sorptive phase is simple as it only requires dipping the paper into an organic solution of the…

AnalyteBioanalysisFormic acid02 engineering and technology01 natural sciencesBiochemistryMass SpectrometryAnalytical Chemistrychemistry.chemical_compoundLimit of DetectionDesorptionPhase (matter)Environmental ChemistryHumansSalivaSpectroscopyDetection limitCoated paperChromatographyChemistry010401 analytical chemistryExtraction (chemistry)021001 nanoscience & nanotechnology0104 chemical sciencesAnti-Bacterial AgentsNylons0210 nano-technologyChromatography LiquidAnalytica chimica acta
researchProduct

Amphetamine-type stimulants analysis in oral fluid based on molecularly imprinting extraction

2018

Abstract A methamphetamine-based molecularly imprinted polymer (MIP) has been prepared by bulk polymerization to recognize new psychoactive substances (NPS) of the amphetamine, cathinones and 2C families in oral fluid samples, being the first precedent of a synthetized MIP for the extraction and preconcentration 32 NPS including amphetamine type substances and synthetic cathinones from oral fluids. Pre-polymerization complex and resulting materials were appropriately characterized by infrared spectroscopy, scanning electron microscopy, and nitrogen adsorption-desorption isotherms. Appropriateness of the material for the specific recognition of the target analytes was also evaluated through …

AnalyteCathinoneIon-mobility spectrometryInfrared spectroscopy02 engineering and technologyChemical FractionationMass spectrometry01 natural sciencesBiochemistryPolymerizationAnalytical ChemistryMolecular ImprintingmedicineHumansEnvironmental ChemistrySolid phase extractionSpectroscopyDetection limitChromatographyChemistrySolid Phase Extraction010401 analytical chemistryMolecularly imprinted polymerGreen Chemistry Technology021001 nanoscience & nanotechnologyBody Fluids0104 chemical sciencesAmphetamineCentral Nervous System StimulantsAdsorption0210 nano-technologymedicine.drugAnalytica Chimica Acta
researchProduct

Control of propranolol intake by direct chromatographic detection of alpha-naphthoxylactic acid in urine.

2002

A rapid chromatographic procedure with a C18 column, a mobile phase of 0.15 M sodium dodecyl sulfate (SDS)-10% (v/v) 1-propanol at pH 3 (0.01 M phosphate buffer), and fluorimetric detection, is reported for the control of propranolol (PPL) intake in urine samples, which are injected directly without any other treatment than filtration. The peak of PPL was only observed in samples taken a few hours after ingestion of the drug due to its extensive conjugation and metabolisation. The detection of several unconjugated PPL metabolites was therefore considered: desisopropylpropranolol (DIP), propranolol glycol (PPG), alpha-naphthoxylactic acid (NLT) and alpha-naphthoxyacetic acid (NAC). NLT showe…

AnalyteClinical BiochemistryAdrenergic beta-AntagonistsUrinePropranololBiochemistrySensitivity and SpecificityAnalytical Chemistrychemistry.chemical_compoundOral administrationmedicineHumansSodium dodecyl sulfateDetection limitChromatographyElutionReproducibility of ResultsCell BiologyGeneral MedicinePropranololSpectrometry FluorescencechemistryMicellar liquid chromatographyLactatesmedicine.drugChromatography LiquidJournal of chromatography. B, Analytical technologies in the biomedical and life sciences
researchProduct

Determination of the herbicide benfuresate by its photo-induced chemiluminescence using flow multicommutation methodology.

2007

The present paper deals with an analytical strategy based on coupling photo-induced chemiluminescence in a multicommutation continuous-flow methodology for the determination of the herbicide benfuresate. The solenoid valve inserted as small segments of the analyte solution was sequentially alternated with segments of the NaOH solution for adjusting the medium for the photodegradation. Both flow rates (sample and medium) were adjusted to required time for photodegradation, 90 s; and then, the resulting solution was also sequentially inserted as segments alternated with segments of the oxidizing solution system, hexacyanoferrate (III) in alkaline medium. The calibration range from 1 microg L(…

AnalyteCorrelation coefficientAnalytical chemistryFresh WaterAlkaliesAnalytical Chemistrylaw.inventionlawOxidizing agentWater Pollution ChemicalHumansPhotodegradationChemiluminescenceBenzofuransDetection limitReproducibilityChromatographyPhotolysisMolecular StructureChemistryHerbicidesVolumetric flow rateFlow Injection AnalysisLuminescent MeasurementsMineral WatersSulfonic AcidsAcidsTalanta
researchProduct

Evaluation of analytical performance of gas chromatography coupled with atmospheric pressure chemical ionization Fourier transform ion cyclotron reso…

2019

Abstract A new analytical method was established and validated for the analysis of eighteen halogenated flame retardants (HFRs)in food products. Gas chromatography (GC) coupled to Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS) employing atmospheric pressure chemical ionization (APCI) was used for the identification and quantitation of contaminants. Intra-laboratory validation of the method was performed with respect to recovery, repeatability, linear calibration ranges, instrumental and method limits of quantitation (i-LOQ and m-LOQ), and trueness was verified where possible by analysis of reference materials (RMs). The validation results indicated recoveries of ana…

AnalyteEnvironmental EngineeringMaterials scienceFood SafetyHalogenationHealth Toxicology and Mutagenesis0208 environmental biotechnologyAtmospheric-pressure chemical ionization02 engineering and technology010501 environmental sciences01 natural sciencesFourier transform ion cyclotron resonanceGas Chromatography-Mass SpectrometryMass SpectrometryCalibrationHalogenated Diphenyl EthersEnvironmental ChemistryHumans0105 earth and related environmental sciencesFlame RetardantsDetection limitChromatographyFourier AnalysisPublic Health Environmental and Occupational HealthGeneral MedicineGeneral ChemistryRepeatabilityCyclotronsPollution020801 environmental engineeringFoodFood productsGas chromatographyFood AnalysisChemosphere
researchProduct

Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.

2017

A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to b…

AnalyteIon-mobility spectrometry02 engineering and technologyMass spectrometry01 natural sciencesBiochemistryAnalytical ChemistryMatrix (chemical analysis)Cocaine-Related DisordersCocaineHumansSolid phase extractionSalivaDetection limitChromatographyChemistryElutionSpectrum Analysis010401 analytical chemistryOrganic ChemistryExtraction (chemistry)Solid Phase ExtractionGeneral Medicine021001 nanoscience & nanotechnology0104 chemical sciences0210 nano-technologyJournal of chromatography. A
researchProduct

Experimental Study of the Oriented Immobilization of Antibodies on Photonic Sensing Structures by Using Protein A as an Intermediate Layer

2018

[EN] A proper antibody immobilization on a biosensor is a crucial step in order to obtain a high sensitivity to be able to detect low target analyte concentrations. In this paper, we present an experimental study of the immobilization process of antibodies as bioreceptors on a photonic ring resonator sensor. A protein A intermediate layer was created on the sensor surface in order to obtain an oriented immobilization of the antibodies, which enhances the interaction with the target antigens to be detected. The anti-bovine serum albumin (antiBSA)-bovine serum albumin (BSA) pair was used as a model for our study. An opto-fluidic setup was developed in order to flow the different reagents and,…

AnalyteMaterials scienceIntegrated photonicsSerum albuminBiosensing TechniquesRing resonator02 engineering and technologylcsh:Chemical technologyBiotecnologia01 natural sciencesBiochemistryAntibodiesArticleAnalytical Chemistry010309 opticsResonatorring resonatorsensorQUIMICA ANALITICATEORIA DE LA SEÑAL Y COMUNICACIONES0103 physical scienceslcsh:TP1-1185Electrical and Electronic EngineeringStaphylococcal Protein AInstrumentationIntegrated photonics; ring resonator; sensor; biosensingSensorDetection limitPhotonsChromatographybiologyBiosensingbusiness.industrySerum Albumin BovineRepeatabilityÒptica021001 nanoscience & nanotechnologyAtomic and Molecular Physics and Opticsbiology.proteinbiosensingPhotonics0210 nano-technologybusinessProtein ABiosensorSensors
researchProduct

Highly Sensitive Detection of Naphthalene in Solvent Vapor Using a Functionalized PBG Refractive Index Sensor

2012

We report an optical refractive index sensor system based on a planar Bragg grating which is functionalized by substituted γ-cyclodextrin to determine low concentrations of naphthalene in solvent vapor. The sensor system exhibits a quasi-instantaneous shift of the Bragg wavelength and is therefore capable for online detection. The overall shift of the Bragg wavelength reveals a linear relationship to the analyte concentration with a gradient of 12.5 ± 1.5 pm/ppm. Due to the spectral resolution and repeatability of the interrogation system, this corresponds to acquisition steps of 80 ppb. Taking into account the experimentally detected signal noise a minimum detection limit of 0.48 ± 0.05 pp…

AnalyteMaterials sciencegas detection; optical sensor; Bragg grating; cyclodextrin; aromatic hydrocarbonsTransducersaromatic hydrocarbonsAnalytical chemistryPhysics::OpticsNaphthaleneslcsh:Chemical technologyBiochemistryNoise (electronics)gas detectionArticleAnalytical ChemistryFiber Bragg gratinglcsh:TP1-1185Electrical and Electronic Engineeringoptical sensorInstrumentationDetection limitCyclodextrinsEquipment DesignAtomic and Molecular Physics and OpticsEquipment Failure AnalysisRefractometryWavelengthTransducercyclodextrinSolventsBragg gratingGasesRefractometryRefractive indexSensors
researchProduct