Search results for "Detection limit"
showing 10 items of 810 documents
Determination of lidocaine in urine at low ppm levels using dispersive microextraction and attenuated total reflectance–Fourier transform infrared me…
2015
Abstract IR spectra provide valuable information about biological systems and can be obtained with compactable and affordable instruments, but the lack of sensitivity of this technique hampers its use in the determination of drugs in clinical fluids. Taking lidocaine as a target molecule, in this paper we introduced a methodology for determining drugs in urine samples using infrared spectroscopy. The lack of sensitivity of the IR was compensated with the combination of an effective and straightforward dispersive liquid–liquid microextraction and the measurement of the dry film of the organic extracts through attenuated total reflectance (ATR). The method developed improves the sensitivity b…
Dispersive liquid–liquid microextraction followed by gas chromatography–mass spectrometry for the determination of nitro musks in surface water and w…
2011
A new, simple, fast and high sensitive analytical method based on dispersive liquid-liquid microextraction (DLLME) followed by gas chromatography-mass spectrometry (GC-MS) for the simultaneous determination of nitro musks in surface water and wastewater samples is presented. Different parameters, such as the nature and volume of both the extraction and disperser solvents and the ionic strength and pH of the aqueous donor phase, were optimized. Under the selected conditions (injection of a mixture of 1 mL of acetone as disperser solvent and 50 μL of chloroform as extraction solvent, no salt addition and no pH adjustment) the figures of merit of the proposed DLLME-GC-MS method were evaluated.…
Enhancing extraction performance of organophosphorus flame retardants in water samples using titanium hierarchical porous silica materials as sorbent…
2021
Abstract A sorbent for the extraction of organophosphorus flame retardants has been proposed, based on UVM-7 (University of Valencia Materials) mesoporous silica doped with titanium. Designed cartridges have been applied to the extraction and preconcentration of flame retardants in water samples, followed by gas chromatography coupled to a mass spectrometry detector. Firstly, UVM-7 materials with different contents of titanium were synthesized and characterized by several techniques, thus confirming the proper mesoporous architecture. The potential of these materials was assessed in comparison with their morphological properties, resulting Ti50-UVM-7 the best solid phase. Several extraction…
Dispersive solid-phase extraction based on oleic acid-coated magnetic nanoparticles followed by gas chromatography-mass spectrometry for UV-filter de…
2011
Abstract A sensitive analytical method to concentrate and determine extensively used UV filters in cosmetic products at (ultra)trace levels in water samples is presented. The method is based on a sample treatment using dispersive solid-phase extraction (dSPE) with laboratory-made chemisorbed oleic acid-coated cobalt ferrite (CoFe 2 O 4 @oleic acid) magnetic nanoparticles (MNPs) as optimized sorbent for the target analytes. The variables involved in dSPE were studied and optimized in terms of sensitivity, and the optimum conditions were: mass of sorbent, 100 mg; donor phase volume, 75 mL; pH, 3; and sodium chloride concentration, 30% (w/v). After dSPE, the MNPs were eluted twice with 1.5 mL …
Reduced graphene oxide-based magnetic composite for trace determination of polycyclic aromatic hydrocarbons in cosmetics by stir bar sorptive dispers…
2020
This work describes a sensitive and rapid analytical method for trace determination of polycyclic aromatic hydrocarbons (PAHs) in cosmetic samples. The proposed method is based on stir bar sorptive-dispersive microextraction (SBSDME). A magnetic composite made of CoFe2O4 magnetic nanoparticles embedded into reduced graphene oxide sheets is used as sorbent phase. After the extraction, the target analytes are desorbed in toluene and then analyzed by gas chromatography-mass spectrometry (GC-MS). The main parameters involved in the extraction procedure (i.e., composite amount, extraction time and desorption time) were evaluated and optimized to provide the best extraction efficiency. The method…
Modified magnetic-based solvent-assisted dispersive solid-phase extraction: application to the determination of cortisol and cortisone in human saliv…
2021
A modification of magnetic-based solvent-assisted dispersive solid-phase extraction (M-SA-DSPE) has been employed for the determination of the biomarkers cortisol and cortisone in saliva samples. M-SA-DSPE is based on the dispersion of the sorbent material by using a disperser solvent like in dispersive solid phase extraction (SA-DSPE) but a magnetic sorbent is used like in magnetic dispersive solid-phase extraction (M-DSPE). Thus, the magnetic sorbent containing the target analytes is retrieved using an external magnet like in M-DSPE. Finally, the analytes are desorbed into a small volume of organic solvent for the subsequent chromatographic analysis. To this regard, a M-SA-DSPE-based meth…
A hybrid nano-MOF/polymer material for trace analysis of fluoroquinolones in complex matrices at microscale by on-line solid-phase extraction capilla…
2021
Abstract A hybrid material (nano-metal organic framework@organic polymer, named as nano-MOF@polymer) was applied for the first time as sorbent for on-line solid-phase extraction capillary electrophoresis with ultraviolet detection (SPE-CE-UV). The resulting material was prepared building layer-by-layer a HKUST-1 (Hong Kong University of Science and Technology-1) nano-MOF onto the polymer surface, which allowed controlling the thickness and maximizing the active surface area. The sorbent was widely characterized at micro- and nano-scale to validate the synthesis and to establish the material properties. Then, fritless microcartridges (2 mm) were assembled by packing only a few micrograms of …
Preconcentration of emerging contaminants in environmental water samples by using silica supported Fe3O4 magnetic nanoparticles for improving mass de…
2011
A magnetic material based on Fe(3)O(4) magnetic nanoparticles incorporated in a silica matrix by using a sol-gel procedure has been used to extract and preconcentrate emerging contaminants such as acetylsalicylic acid, acetaminophen, diclofenac and ibuprofen from environmental water samples prior to the analysis with Capillary LC-MS. The use of the proposed silica supported Fe(3)O(4) magnetic nanoparticles enables surfactant free extracts for the analysis with MS detection without interferences in the ionisation step. Under the optimum conditions, we demonstrated the reusability of the magnetic sorbent material during 20 uses without loss in the extraction efficiency. In addition, no cleanu…
Rapid whole protein quantitation of staphylococcal enterotoxins A and B by liquid chromatography/mass spectrometry
2012
Abstract Staphylococcus aureus is an important pathogen and has been indicated as the fifth causative agent of food-borne human illness throughout the world. Staphylococcal enterotoxins (SEs) are toxic compounds excreted mainly by strains of S. aureus. Among these toxins, enterotoxins A (SEA) and B (SEB) are both of the most prevalent compounds in staphylococcal food poisoning. In this work, reverse phase liquid chromatography coupled to ESI mass spectrometry (LC–ESI/MS) has been applied for its rapid identification and quantification. Limit of detection (LOD) values were 0.5 and 0.2 ng for SEA and SEB, respectively and limit of quantification (LOQ) value was 1 ng for both enterotoxins. SEA…
Estimation of alcohol consumption during >Fallas> festivity in the wastewater of Valencia city (Spain) using ethyl sulfate as a biomarker
2016
Alcohol consumption has been increasing in the last years and it has become a sociological problem due its derived health and safety problems. Ethyl sulfate is a secondary metabolite of the alcohol degradation that is excreted through the urine (0.010-0.016%) after alcohol ingestion and it is quite stable in water. In this study, a new methodology to determine ethyl sulfate by ion-pair liquid chromatography-tandem mass spectrometry (LC-MS/MS) was developed. Different ion-pairs and additives were tested directly in the sample extracts or in the mobile phase. The best ion-pair was set up adding 0.5M of tributylamine and 0.1% of formic acid to the sample. The limit of quantification was 0.3μgL…