Search results for "Detectors"

showing 10 items of 2229 documents

Resolution, efficiency and stability of HPGe detector operating in a magnetic field at various gamma-ray energies

2008

Abstract The use of High Purity Germanium detectors (HPGe) has been planned in some future experiments of hadronic physics. The crystals will be located close to large spectrometers where the magnetic fringing field will not be negligible and their performances might change. Moreover high precision is required in these experiments. The contribution of magnetic field presence and long term measurements is unique. In this paper the results of systematic measurements of the resolution, stability and efficiency of a crystal operating inside a magnetic field of 0.8 T, using radioactive sources in the energy range from 0.08 to 1.33 MeV, are reported. The measurements have been repeated during sev…

PhysicsNuclear and High Energy PhysicsSpectrometerField (physics)HPGe; PANDA; Double HypernucleiPANDAResolution (electron density)DetectorHPGe detectorsGamma raychemistry.chemical_elementHPGe detectors; hypernuclear gamma-ray spectroscopy; magnetic fieldGermaniummagnetic fieldSemiconductor detectorComputational physicsMagnetic fieldNuclear physicshypernuclear gamma-ray spectroscopychemistryDouble HypernucleiHPGeNuclear ExperimentInstrumentation
researchProduct

A New Front-End High-Resolution Sampling Board for the New-Generation Electronics of EXOGAM2 and NEDA Detectors

2015

19th Real Time Conference (RT) -- MAY 26-30, 2014 -- Nara, JAPAN WOS: 000356458000028 This paper presents the final design and results of the FADC Mezzanine for the EXOGAM (EXOtic GAMma array spectrometer) and NEDA (Neutron Detector Array) detectors. The measurements performed include those of studying the effective number of bits, the energy resolution using HP-Ge detectors, as well as timing histograms and discrimination performance. Finally, the conclusion shows how a common digitizing device has been integrated in the experimental environment of two very different detectors which combine both low-noise acquisition and fast sampling rates. Not only the integration fulfilled the expected …

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and DetectorsDetectorBandwidth (signal processing)Acquisition in HP-Ge detectorshigh-speed ADCsFront and back endshigh-speed ADCEffective number of bitsAcquisition in HP-Ge detectorNuclear Energy and Engineeringlow-noise electronics designElectronic engineeringNeutron detectionNeutronElectronics[PHYS.PHYS.PHYS-INS-DET]Physics [physics]/Physics [physics]/Instrumentation and Detectors [physics.ins-det]Electrical and Electronic Engineering
researchProduct

Cubic boron nitride: A new prospective material for ultracold neutron application

2009

Abstract At the ultracold neutron (UCN) source of the TRIGA research reactor in Mainz, we have measured for the first time the material optical wall-potential of cubic boron nitride. The measurements were performed with a time-of-flight (TOF) spectrometer. The samples investigated had a wall-potential of ( 305 ± 15 ) neV . This value is in good agreement with the result extracted from neutron reflectometry data and theoretical expectations. Because of its high critical velocity for UCN and its good dielectric characteristics, cubic boron nitride coatings (isotopically enriched) will be useful for a number of applications in UCN experiments.

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and DetectorsFOS: Physical sciencesDielectricCritical ionization velocityTRIGACondensed Matter::Materials Sciencechemistry.chemical_compoundNuclear magnetic resonancechemistryBoron nitrideNeutronResearch reactorNeutron reflectometryNuclear Experiment (nucl-ex)Atomic physicsNuclear ExperimentNuclear ExperimentInstrumentation
researchProduct

Time response of TOF spectrometer to light and heavy particles

2002

Comparing time of flight (TOF) values for α particles and fission fragments measured at different distances between the start- and stop detector we have obtained 60 ps as the upper limit for the TOF error resulting from the assumption of equal and linear time calibrations for both types of particles. While the 60 ps limit relates only to the specific spectrometer, the problem and the suggested verification technique are of general interest.

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and DetectorsFissionDetectorAnalytical chemistryAlpha particleTime of flightTime responseMicrochannel plate detectorLimit (mathematics)Nuclear ExperimentInstrumentationNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

The GREAT spectrometer

2003

Abstract The GREAT spectrometer is designed to measure the decay properties of reaction products transported to the focal plane of a recoil separator. GREAT comprises a system of silicon, germanium and gas detectors optimised for detecting the arrival of the reaction products and correlating with any subsequent radioactive decay involving the emission of protons, α particles, β particles, γ rays, X-rays or conversion electrons. GREAT can either be employed as a sensitive stand-alone device for decay measurements at the focal plane, or used to provide a selective tag for prompt conversion electrons or γ rays measured with arrays of detectors deployed at the target position. A new concept of …

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryAlpha particleDead timeCharged particleParticle detectorSemiconductor detectorNuclear physicsOpticsBeta particlebusinessInstrumentationRadioactive decayNuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
researchProduct

Electron-TOF-analyser for complete momentum analysis in photoemission from surfaces

2001

Abstract We present a new method for momentum-selective imaging by means of a time-of-flight (TOF) technique. The instrument employs a time- and space-resolving delayline detector in combination with a parabolic electrostatic field and a drift space. We use this kind of spectrometer, to raise the efficiency of experiments, which are total momentum resolved. The main difference to conventional photoemission experiments using a rotatable spectrometer is the simultaneous detection of all emitted photoelectrons. In addition to this feature, the angular distribution should be directly visible, to observe solid state symmetries. In order to facilitate these requirements, we use a delayline detect…

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryAnalyserDetectorPhotoelectric effectParticle detectorMomentumTime of flightOpticsMeasuring instrumentbusinessInstrumentation
researchProduct

Efficiency studies for a tracking detector based on square 1.5m long scintillating fibers read out by SiPM

2009

Abstract A tracking detector based on 1.5 m long scintillating fibers is being developed for the electron arm of the KAOS spectrometer at the Mainz Microtron MAMI. Measurements on light attenuation, particle detection efficiencies and accidental coincidence rates with a prototype set-up using 2 × 2 mm 2 fibers read out by silicon photomultipliers (SiPM) are presented. The highest efficiency at the lowest accidental coincidence rate was reached for high trigger thresholds at the largest SiPM bias voltages. The influence of signal attenuation and dispersion on detection efficiencies is discussed. The results are in good agreement with a Monte Carlo model that was used to predict detector char…

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryAttenuationMonte Carlo methodDetectorTracking (particle physics)Silicon photomultiplierOpticsDispersion (optics)OptoelectronicsNuclear ExperimentbusinessInstrumentationMicrotronNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Triple GEM tracking detectors for COMPASS

2002

The small area tracker of COMPASS, a high-luminosity fixed target experiment at CERN's SPS, includes a set of 20 large-size ($31\times 31\,\cm^2$) Gas Electron Multiplier (GEM) detectors. Based on gas amplification in three cascaded GEM foils, these devices permit to obtain high gain and good spatial resolution even at very high particle fluxes. A two-coordinate projective readout yields, for each track, highly correlated signal amplitudes on both projections, allowing to resolve multiple hits in high occupancy regions close to the central deactivated area of $5\,\cm$ diameter. At the same time the material exposed to the beam is minimized. Splitting the amplification in three cascaded stag…

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryDetectorTracking (particle physics)Nuclear physicsOpticsNuclear Energy and EngineeringCompassNuclear electronicsGas electron multiplierDetectors and Experimental TechniquesElectrical and Electronic EngineeringbusinessImage resolutionBeam (structure)IEEE Transactions on Nuclear Science
researchProduct

Polarization phenomena in Al/p-CdTe/Pt X-ray detectors

2013

Over the last decades, CdTe detectors are widely used for the development of room temperature X-ray and gamma ray spectrometers. Typically, high resolution CdTe detectors are fabricated with blocking contacts (indium, aluminum) ensuring low leakage currents and high electric field for optimum charge collection. As well known, time instability under bias voltage (termed as polarization) is the major drawback of CdTe diode detectors. Polarization phenomena cause a progressive degradation of the spectroscopic performance with time, due to hole trapping and detrapping from deep acceptors levels. In this work, we studied the polarization phenomenon on new Al/p-CdTe/Pt detectors, manufactured by …

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industryX-ray detectorchemistry.chemical_elementBiasingAcceptorCadmium telluride photovoltaicsSchottky CdTe detectorCondensed Matter::Materials SciencechemistryPolarizationElectric fieldActivation energyX-rayandgamma ray spectroscopyOptoelectronicsbusinessPolarization (electrochemistry)InstrumentationIndiumNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Study of background characteristics of a low-level HPGe spectrometer with passive shielding in various configurations

1997

Abstract A low-background germanium spectrometer has been investigated with different combinations of shielding materials in two locations at ground level. In particular, seven shielding configurations have been tested in a room with thick walls and ceiling. The background components, peaks and continuum in the 50–2600 keV energy region, obtained in the several experimental conditions are reported and discussed.

PhysicsNuclear and High Energy PhysicsSpectrometerPhysics::Instrumentation and Detectorsbusiness.industrychemistry.chemical_elementGermaniumSemiconductor detectorGround levelOpticschemistryElectromagnetic shieldingbusinessInstrumentationNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct