Search results for "Detectors"
showing 10 items of 2229 documents
Development of a High Precision Axial 3-D PET for Brain Imaging
2009
We describe a PET device based on a novel method to extract the coordinates of the interaction point of the 511keV γ rays from 100 mm long and thin LYSO (Lutetium Yttrium OxyorthoSilicate) scintillator bars, positioned axially in the tomograph. The coordinate along the hit crystal is measured by using a hodoscope of Wave Length Shifting (WLS) plastic strips mounted perpendicularly to each plane of scintillators. As photodetectors, new Geiger mode Avalanche PhotoDetectors (G-APDs) with integrated electronics are being used to detect both the hit crystal in a block (x and y coordinates) and the interaction point in the crystal (z coordinate) through the light escaping from the crystal and tra…
Study of the γ decay of high-lying states in 208Pb via inelastic scattering of 17O ions
2014
A measurement of the high-lying states in 208Pb has been made using 17O beams at 20 MeV/u. The gamma decay following inelastic excitation was measured with the detector system AGATA Demonstrator based on segmented HPGe detectors, coupled to an array of large volume LaBr3:Ce scintillators and to an array of Si detectors. Preliminary results in comparison with (γ,γ’) data, for states in the 5-8 MeV energy interval, are presented.
Cosmic ray effect on the X-ray Trigger Telescope of UFFO/Lomonosov using YSO scintillation crystal array in space
2017
UFFO Burst Alert and Trigger telescope (UBAT) is the X-ray trigger telescope of UFFO/Lomonosov to localize X-ray source with coded mask method and X-ray detector. Its X-ray detector is made up of 36 8×8 pixels Yttrium OxyorthoSilicate (Y2SiO5:Ce, YSO) scintillation crystal arrays and 36 64-channel Multi-Anode PhotoMultiplier Tubes (MAPMTs) for space mission. Its effective detection area is 161cm2 and energy range is several keV to 150 keV. It was successfully launched in April 28, 2016. In several calibration run, we got several X-ray background data. We already knew X-ray background flux is 2-3 counts/cm2/sec in space. However our X-ray background data shows approximately 7-8 times higher …
The Gas Scintillation Proportional Counter on EXOSAT
1981
The inclusion of a gas scintillation proportional counter (GSPC) within the EXOSAT payload complement significantly improves the spectroscopic capability of the mission. This broad-band medium energy spectrometer used in conjunction with the large area proportioni counter array (ME) should provide additional spectroscopic details on strong X-ray sources at photon energies above ~ 2 keV. The novel type of detector has an energy resolution at least a factor of two better than the ME experiment over a similar bandwidth (2 – 40 keV).
Expected performance of an ideal liquid argon neutrino detector with enhanced sensitivity to scintillation light
2014
Scintillation light is used in liquid argon (LAr) neutrino detectors to provide a trigger signal, veto information against cosmic rays, and absolute event timing. In this work, we discuss additional opportunities offered by detectors with enhanced sensitivity to scintillation light, that is with light collection efficiencies of about $10^{-3}$. We focus on two key detector performance indicators for neutrino oscillation physics: calorimetric neutrino energy reconstruction and neutrino/antineutrino separation in a non-magnetized detector. Our results are based on detailed simulations, with neutrino interactions modelled according to the GENIE event generator, while the charge and light respo…
The features of electronics structure of the multichannel scintillation module for the EMMA experiment
2011
A brief description of the developed structural electric diagrams of 16-channel scintillation module for the underground EMMA experiment, the basic characteristics and parameters of the electrical diagrams of this module are presented. Multi-pixel photodiodes operating in a limited Geiger mode are used for photoreadout of the scintillator detectors in 16-channel scintillation module. The method of the automatic tuning of the photosensors gain based on the stabilization of an average counting rate of the scintillation detectors from gamma rays of a natural radioactive background is described. peerReviewed
Dark matter searches using superheated liquids
2016
Direct detection of dark matter is one of the most important topics in modern physics. It is estimated that 22% of universe matter is composed by dark matter in front of 0.4% of ordinary matter like stars, galaxies planets and all kind of known astrophysical objects. Several kinds of experiments are nowadays involved in detection of one of the more accepted particle candidates to be dark matter: WIMPs (Weakly Interacting Massive Particles). These detectors, using several kinds of techniques: Cryogenic semiconductors, scintillation materials like I Na or noble gas chambers among others, are reporting very interesting but inconclusive results. In this paper a review of detectors that are usin…
Searching for $B_c$ mesons in the ATLAS experiment at LHC
1995
We discuss the feasibility of the observation of the signal from $B_c$ mesons in the ATLAS experiment at the LHC. In particular, we address the decay mode $B_c{\rightarrow}J/\psi \pi$ followed by the leptonic decay $J/\psi{\rightarrow}\mu^+\mu^-$, which should permit an accurate measurement of the $B_c$ mass. We performed a Monte Carlo study of the signal and background concluding that a precision of $\approx$ 1 MeV for the $B_c$ mass could be achieved after one year of running at $\lq\lq$low" luminosity. The semileptonic decay $B_c{\rightarrow}J/\psi\ {\mu}^+{\nu}_{\mu}$ is also considered for a possible extraction of ${\mid}V_{cb}{\mid}$.
First coincidences in pre-clinical Compton camera prototype for medical imaging
2003
Abstract Compton collimated imaging may improve the detection of gamma rays emitted by radioisotopes used in single photon emission computed tomography (SPECT). We present a crude prototype consisting of a single 500 μm thick, 256 pad silicon detector with pad size of 1.4×1.4 mm 2 , combined with a 15×15×1 cm 3 NaI scintillator crystal coupled to a set of 20 photo multipliers. Emphasis is placed on the performance of the silicon detector and the associated read-out electronics, which has so far proved to be the most challenging part of the set-up. Results were obtained using the VATAGP3, 128 channel low-noise self-triggering ASIC as the silicon detector's front-end. The noise distribution (…
JEM-X: three years in space
2006
We report on the technical and scientific performance of JEM-X, the X-ray monitor on ESA's INTEGRAL mission. INTEGRAL has now been in orbit for more than three years, and the mission is foreseen to be extended until the end of 2010. Overall, JEM-X performs very well, and can be expected to continue to do so for the duration of the mission. We discuss in some detail the operational experiences and the problems encountered with the microstrip detectors caused by the space environment and give one example of the interesting scientific results obtained. The analysis software is still being improved on, and we discuss briefly the significance of these improvements.