Search results for "Device"

showing 10 items of 1286 documents

Experimental study and physical modeling of simultaneous heat and moisture transfer in bio-sourced insulating materials.

2019

The conventional heat transfer models are not sufficiently suitable for thermal characterization of bio-sourced thermal insulating materials due to their strongly hydrophilic nature. The proposed work in this PhD thesis aims to answer this problem with experimental and theoretical approaches of coupled heat-moisture transfers. In the experimental approach, a thermal insulating material based on Flax Fiber Felt (FFF) is developed and then characterized at different hygrometric conditions with an asymmetric hot plate device. The humidity diffusion characterization of the samples is done using the GAB, GDW and Park theoretical moisture adsorption isotherm models. In the theoretical approach, a…

Centered hot-Plate devicePropriétés thermophysiquesTransferts couplés chaleur-MasseAdsorption isothermsThermophysical properties[SPI.MECA.THER]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Thermics [physics.class-ph]Coupled heat-Mass transferIsothermes d'adsorptionThermal insulationMéthode plan chaudIsolation thermique[SPI.MECA.THER] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Thermics [physics.class-ph]
researchProduct

Fracture resistance and the mode of failure produced in metal-free crowns cemented onto zirconia abutments in dental implants.

2019

The purpose of the investigation was to analyze fracture resistance and mode of failure of zirconium oxide (zirconia) abutments placed on dental implants bearing crowns of different esthetic materials: zirconia, lithium disilicate (LDS), and nano-ceramic resin, for replacing single teeth in the anterior sector. Eighty implant-abutment-crown units were divided into four groups: Group T-MC (control): 20 metal-ceramic crowns cemented onto titanium abutments; Group Z-Z: 20 zirconia crowns on zirconia abutments; Group Z-LD: 20 lithium disilicate crowns on zirconia abutments; and Group Z-NCR: 20 nano-ceramic resin crowns on zirconia abutments. Specimens underwent a fatiguing process (dynamic load…

CeramicsTeethMedical Implantsmedicine.medical_treatmentDentistry02 engineering and technologyMaterial Fatigue0302 clinical medicineMaterials PhysicsMaterials TestingMedicine and Health SciencesCubic zirconiaDental Restoration FailureMaterialsDental CementumTitaniumProstheticsMultidisciplinaryCrownsPhysicsQRClassical Mechanics021001 nanoscience & nanotechnologyChemistryPhysical SciencesMedicineEngineering and TechnologyAnatomy0210 nano-technologyTitaniumResearch ArticleBiotechnologyChemical ElementsMaterials scienceScienceBiomaterial ImplantsMaterials ScienceAbutmentchemistry.chemical_elementBioengineeringLithiumCrown (dentistry)Anterior region03 medical and health sciencesmedicineHumansTitanium ImplantsDental ImplantsDamage Mechanicsbusiness.industryBiology and Life Sciences030206 dentistryDental PorcelainAssistive TechnologieschemistryMetal freeJawFracture (geology)Zirconium oxideMedical Devices and EquipmentZirconiumbusinessDigestive SystemHeadPloS one
researchProduct

Validity and reliability of Veloflex to measure active cervical range of motion in asymptomatic and symptomatic subjects

2021

Background Neck pain has a high annual incidence and decreases the cervical active range of motion (ROM). Clinicians use various methods to evaluate cervical range of motion (CROM) that some of them have also been proposed to give instant feedback. Accordingly, this study aimed to examine the validity and reliability of Veloflex (VF) to measure the CROM by comparison with the cervical range of motion (CROM) device, and to examine their test-retest reliability. Methods Thirty-eight healthy and 20 symptomatic participants were evaluated. Cervical flexion-extension, side bending, and rotations were tested in two sessions, first by the CROM and VF and in the second only with the VF. To evaluat…

Cervical range of motionDrugs and Devices030506 rehabilitationmedicine.medical_specialtyAnatomy and PhysiologyConcurrent validityValidity/reliabilitylcsh:MedicineValidityAsymptomaticGeneral Biochemistry Genetics and Molecular Biology03 medical and health sciencessymbols.namesake0302 clinical medicinePhysical medicine and rehabilitationMedicineRange of motionAnesthesiology and Pain ManagementOptoelectronic deviceReliability (statistics)business.industryGeneral Neurosciencelcsh:RGeneral MedicineKinesiologyPearson product-moment correlation coefficientOrthopedicsStandard errorsymbolsCervicalmedicine.symptom0305 other medical scienceGeneral Agricultural and Biological SciencesRange of motionbusiness030217 neurology & neurosurgeryPeerJ
researchProduct

Taopatch® combined with home-based training protocol to prevent sedentary lifestyle and biochemical changes in MS patients during COVID-19 pandemic

2021

In Multiple sclerosis (MS) it is important to preserve the residual physiological functions of subjects. The aim of the present study was to investigate the influence of nanotechnological device treatment combined with home-based training program (TP) on lactate level, hand grip strength and cervical mobility on MS patients. Seventeen MS patients were enrolled in the study and randomly assigned to an experimental group (EG) in which the Taopatch® nanotechnological device was applied or to a control group (CG). All the participants carried out a cervical range of motion (1) assessment and the hand grip test at baseline (T0) and after TP (T1), also investigating the lactate levels to figure o…

Cervical range of motionmedicine.medical_specialtyCoronavirus disease 2019 (COVID-19)light therapyTaopatch®hand grip testcervical range of motionArticleGrip strengthSettore BIO/10 - BiochimicaHand strengthnanotechnology-based deviceMedicineOrthopedics and Sports MedicineTaopatchMolecular BiologySedentary lifestylelactatebusiness.industryQM1-695RCell BiologyHome-based training programHome basedSample size determinationHuman anatomyPhysical therapyMedicineNeurology (clinical)businessTraining programEuropean Journal of Translational Myology
researchProduct

Transcranial Magnetic Stimulation Combined With Nicotine Replacement Therapy for Smoking Cessation: A Randomized Controlled Trial.

2015

Abstract Background Further evidence suggests that repetitive Transcranial Magnetic Stimulation (rTMS) is an effective method to reduce tobacco craving among smokers. Hypothesis As relapse is common within a few days after smoking cessation, we hypothesized that combining the anti-craving effects of rTMS with Nicotine replacement therapy (NRT) to attenuate withdrawal symptoms could increase abstinence rates in smokers with severe nicotine dependence who quit smoking. Methods Thirty-seven smokers who failed to quit with the usual treatments were randomly assigned to two treatment groups to receive either active ( n  = 18) or sham ( n  = 19) 1-Hz rTMS of the right dorsolateral prefrontal cort…

CessationAdultMaleNicotinemedicine.medical_specialtymedicine.medical_treatmentmedia_common.quotation_subjectBiophysicsPrefrontal CortexCravingbehavioral disciplines and activitieslcsh:RC321-571law.inventionNicotineYoung AdultRandomized controlled triallawTobaccomental disordersmedicineHumansSingle-Blind MethodPsychiatrylcsh:Neurosciences. Biological psychiatry. Neuropsychiatrymedia_commonCravingGeneral NeuroscienceTobacco Use DisorderAbstinenceMiddle AgedNicotine replacement therapyCombined Modality TherapyTranscranial Magnetic StimulationTobacco Use Cessation DevicesTranscranial magnetic stimulationTreatment Outcomenervous systemAnesthesiaCombinationbehavior and behavior mechanismsSmoking cessationFemaleSmoking CessationNeurology (clinical)medicine.symptomTobacco Use Cessation ProductsPsychologypsychological phenomena and processesmedicine.drugBrain stimulation
researchProduct

Overview of the JET results

2015

Since the installation of an ITER-like wall, the JET programme has focused on the consolidation of ITER design choices and the preparation for ITER operation, with a specific emphasis given to the bulk tungsten melt experiment, which has been crucial for the final decision on the material choice for the day-one tungsten divertor in ITER. Integrated scenarios have been progressed with the re-establishment of long-pulse, high-confinement H-modes by optimizing the magnetic configuration and the use of ICRH to avoid tungsten impurity accumulation. Stationary discharges with detached divertor conditions and small edge localized modes have been demonstrated by nitrogen seeding. The differences in…

Chemical analysiMagnetic confinementEdge localized modeTokamak:Física [Ciências exactas e naturais]Nuclear engineeringplasma-facing componentsTungsten7. Clean energyiter-like walllaw.inventionheat loadsAlcator C-ModlawPlasma-facing componentalcator C-MODQCPhysicsJet (fluid)Thermally activatedDivertormagnetic confinementMagnetic confinement fusionTokamak deviceerosionCondensed Matter PhysicsChemical erosionPost mortem analysiCondensed Matter Physics; Nuclear and High Energy PhysicsBerylliumAtomic physicstokamaksTokamaksNuclear and High Energy Physicschemistry.chemical_elementImpurity accumulationCondensed Matter PhysicNuclear and High Energy Physics; Condensed Matter PhysicsTungstenFísica Física:Physical sciences [Natural sciences]divertorNuclear fusionNuclear and High Energy PhysicPhysics Physical sciencesGas fuel analysifuel retentionSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)operationOrders of magnitudechemistryJETtransportMagnetic configuration
researchProduct

Synergies between Hyperpolarized NMR and Microfluidics: A Review

2021

Hyperpolarized nuclear magnetic resonance and lab-on-a-chip microfluidics are two dynamic, but until recently quite distinct, fields of research. Recent developments in both areas increased their synergistic overlap. By microfluidic integration, many complex experimental steps can be brought together onto a single platform. Microfluidic devices are therefore increasingly finding applications in medical diagnostics, forensic analysis, and biomedical research. In particular, they provide novel and powerful ways to culture cells, cell aggregates, and even functional models of entire organs. Nuclear magnetic resonance is a non-invasive, high-resolution spectroscopic technique which allows real-…

Chemical processNuclear and High Energy PhysicsMedical diagnosticMagnetic Resonance SpectroscopyPHYSICAL MANIPULATIONSComputer scienceProcess (engineering)MicrofluidicsMicrofluidicsFOS: Physical sciencesContext (language use)Nanotechnology02 engineering and technology010402 general chemistry01 natural sciencesBiochemistryAnalytical ChemistryLab-On-A-Chip DevicesPhysics - Chemical PhysicsHyperpolarization (physics)SpectroscopyChemical Physics (physics.chem-ph)021001 nanoscience & nanotechnologyMagnetic Resonance Imaging0104 chemical sciences0210 nano-technologyProgress in Nuclear Magnetic Resonance Spectroscopy
researchProduct

Use of semipermeable membrane devices for assessment of air quality in Tangier (Morocco)

2009

Semipermeable membrane devices (SPMDs) have been used for the evaluation of the contamination of air in both the urban and the industrial area in Tangier (Morocco). Benzene, toluene, ethylbenzene a...

ChemistryHealth Toxicology and MutagenesisIndustrial areaPublic Health Environmental and Occupational HealthSoil ScienceBTEXPollutionEthylbenzeneAnalytical ChemistryAir contaminationchemistry.chemical_compoundAir pollutantsSemipermeable membrane devicesEnvironmental chemistryEnvironmental ChemistryWaste Management and DisposalAir quality indexWater Science and TechnologyPassive samplingInternational Journal of Environmental Analytical Chemistry
researchProduct

Synthesis, characterization, and hierarchical organization of tungsten oxide nanorods: spreading driven by Marangoni flow.

2009

Tungsten oxide nanorods were synthesized by a soft chemistry approach using tungsten alkoxide and trioctyl amine and oleic acid as the surfactants. The optical properties of the nanorods were studied. The nanorods were found to be soluble in a wide range of solvents like chloroform, cyclohexane, and so on. Upon solvent evaporation, the nanorods formed hierarchically organized solid state structures. Depending on the solvent used, the nanorods organized in different mesostructures. Moreover, the organization of the nanorods from mixtures of polar and nonpolar solvents was studied. Here, the Marangoni effect resulting from differences in the surface tensions of the two solvents was found to p…

ChemistryInorganic chemistrychemistry.chemical_elementGeneral ChemistryTungstenElectrochromic devicesBiochemistryDip-coatingCatalysisSoft chemistrySolventchemistry.chemical_compoundColloid and Surface ChemistryChemical engineeringAlkoxideNanorodThin filmJournal of the American Chemical Society
researchProduct

Metabolic Status and Reaction to Heat of Normal and Tumor Tissue

1995

The occurrence of differential heating and differential thermal sensitivity between malignant tumors and normal tissues is thought to be due to limited heat dissipation and energy depletion in many solid tumors which in turn results from an inadequately functioning tumor microcirculation (Jain and Ward-Hartley 1984; Song 1984, 1991; Vaupel and Kallinowski 1987; Reinhold 1988; Vaupel et al. 1988a; Vaupel 1990). As a consequence of the latter pathophysiological condition, supply and drainage function are restricted in many solid tumors or, at least, in some tumor areas, thus creating a hostile metabolic microenvironment characterized by tissue hypoxia, acidosis, and energy depletion. Thermal …

ChemistrymedicineCancer researchNormal tissueTissue hypoxiaFunctioning tumorThermal management of electronic devices and systemsmedicine.symptomTumor tissuePerfusionAcidosisMicrocirculation
researchProduct