Search results for "Diagnostic Errors"
showing 7 items of 37 documents
The supraventricular tachycardias: Proposal of a diagnostic algorithm for the narrow complex tachycardias
2013
AbstractThe narrow complex tachycardias (NCTs) are defined by the presence in a 12-lead electrocardiogram (ECG) of a QRS complex duration less than 120ms and a heart rate greater than 100 beats per minute; those are typically of supraventricular origin, although rarely narrow complex ventricular tachycardias have been reported in the literature.As some studies document, to diagnose correctly the NCTs is an arduous exercise because sometimes those have similar presentation on the ECG. In this paper, we have reviewed the physiopathological, clinical, and ECG findings of all known supraventricular tachycardias and, in order to reduce the possible diagnostic errors on the ECG, we have proposed …
Ligneous Cervicitis in a Woman With Plasminogen Deficiency Associated With an Atypical Form of Microglandular Hyperplasia
2013
A 19-yr-old woman with previously diagnosed clear cell adenocarcinoma was referred to the Charité for further treatment. Biopsies were taken from the cervix, the endometrium, pseudomembranes in the peritoneum, and sentinel lymph nodes. The morphologic picture of pseudomembranes and inflammation together with the provided information about plasminogen deficiency of the patients led to the hypothesis of ligneous cervicitis. The previously taken biopsies of the adenocarcinoma were reevaluated and showed a clear cell lesion. Further immunohistochemical examination with antibodies against p16, Ki67, CEA, and p53 could not prove its malignant character. As a result we diagnosed an atypical form o…
Worm-like artifacts in exfoliative cytology.
2006
The presence of worms in cytological smears is occasionally reported, although various other structures exist that may be confused with such parasites. We present eight worm-like artifacts observed in routine Papanicolaou smears. Recognition of these structures is important to avoid overvaluation or confusion with true worms. Diagn. Cytopathol. 2006;34:636–639. © 2006 Wiley–Liss, Inc.
Blood Transfusion Management for Patients Treated With Anti-CD38 Monoclonal Antibodies
2018
Daratumumab has proven to be highly efficacious for relapsed and refractory multiple myeloma (MM) and has recently been approved in the frontline setting for MM patients ineligible for transplantation. In the future, expanded indications are possible for daratumumab and other anti-CD38 monoclonal antibodies in development. For several years, it has been recognized that these therapies interfere with blood bank testing by binding to CD38 on red blood cells and causing panagglutination on the Indirect Antiglobulin Test. This can lead to redundant testing and significant delays in patient care. Given the anticipated increase in utilization of anti-CD38 monoclonal antibodies, as well as the tra…
Trichostasis spinulosa misdiagnosed as alopecia areata.
2020
Pitfalls in whole body MRI with diffusion weighted imaging performed on patients with lymphoma: What radiologists should know
2016
The technological advances in radiological imaging and the relevance of a diagnostic tool that may reduce radiation-induced long-term effects have led to a widespread use of whole body magnetic resonance imaging (WB-MRI) with diffusion weighted imaging for oncologic patients. A lot of studies demonstrated the feasibility and reliability of WB-MRI as an alternative technique for lymphoma staging and response assessment during and after treatment. In this paper, taking advantage of our 2years of experience using WB-MRI for lymphoma, we discuss the main pitfalls and artifacts radiologists should know examining a WB-MRI performed on this typology of patients in order to avoid images misinterpre…
Physical activity - an important preanalytical variable
2014
The concentration of several biochemical and hematological biomarkers is strongly influenced by a number of preanalytical variables. Several lines of evidence attest that short, middle, and long-term exercise, as well as the relative intensity of physical effort (from mild to strenuous), may influence a broad array of laboratory variables. The amount of extracellular release and clearance from blood of most of these biomarkers is markedly influenced by the biological characteristics of the molecule(s), level of training, type, intensity and duration of exercise, and time of recovery after training. It is hence noteworthy that test results that fall outside the conventional reference ranges …