Search results for "Diameter"

showing 10 items of 189 documents

Effect of Kernels Used for the Reconstruction of MDCT Datasets on the Semi-Automated Segmentation and Volumetry of Liver Lesions

2014

Purpose: To evaluate the effect of different reconstruction kernels on the semi-automated segmentation of liver lesions in MDCT. Materials and Methods: A total 62 liver lesions were measured by three independent radiologists with the semi-automated segmentation software Oncology-Prototype (Fraunhofer MEVIS, Siemens Healthcare, Germany) using MDCT datasets (3-mm slice thickness, 2-mm increment) reconstructed with standard, soft and detailed kernels (Philips B, A and D). To ensure objective measurements, only lesions with satisfactory initial segmentation were included, and manual correction was not used. The effective diameter and volume were recorded for each lesion. Segmentation in the sof…

AdultMalemedicine.medical_specialtyLung NeoplasmsInitial SeedAutomated segmentationBreast NeoplasmsTumor responseSensitivity and SpecificityMultidetector Computed TomographyImage Processing Computer-AssistedmedicineHumansRadiology Nuclear Medicine and imagingSegmentationTumor growthAgedMathematicsAged 80 and overbusiness.industryLiver NeoplasmsPattern recognitionSpiral Cone-Beam Computed TomographyGold standard (test)Middle AgedTumor BurdenEffective diameterLiverKernel (statistics)FemaleArtificial intelligenceRadiologyColorectal NeoplasmsbusinessSoftwareRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Relationship between aortic root size and glomerular filtration rate in hypertensive patients

2016

OBJECTIVE: Recent studies suggest that enlarged aortic root diameter (ARD) may predict cardiovascular events in absence of aneurysmatic alterations. Little is known about the influence of renal function on ARD. Our study was aimed to assess the relationships between glomerular filtration rate (GFR) and ARD in hypertensive subjects. METHODS: We enrolled 611 hypertensive individuals (mean age: 52 ± 15 years; men 63%). ARD was measured by echocardiography at the level of Valsalva's sinuses using M-mode tracings. It was considered as absolute measure, normalized to body surface area (ARD/BSA) and indexed to height (ARD/H). GFR was estimated by the Chronic Kidney Disease Epidemiology Collaborati…

AdultMalemedicine.medical_specialtySettore MED/09 - Medicina InternaPhysiologyBody Surface AreaAortic DiseasesRenal functionAorta Thoracic030204 cardiovascular system & hematologySeverity of Illness Index03 medical and health sciences0302 clinical medicineRisk FactorsInternal medicinemedicine.arterySeverity of illnessEpidemiologyInternal MedicinemedicineHumans030212 general & internal medicineRenal Insufficiency ChronicAgedBody surface areaSettore MED/14 - NefrologiaAortaaortic root diameter arterial hypertension cardiovascular risk chronic kidney disease echocardiography glomerular filtration ratebusiness.industryConfoundingOrgan SizeMiddle Agedmedicine.diseaseSettore MED/11 - Malattie Dell'Apparato CardiovascolareCardiovascular DiseasesEchocardiographyHypertensionCardiologyLinear ModelsPopulation studyFemaleCardiology and Cardiovascular MedicinebusinessKidney diseaseGlomerular Filtration Rate
researchProduct

Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents.

1993

AbstractObjectives. The purpose of this study was to measure elastic recoil from sequential angiograms after balloon angioplasty and after implantation of a balloon-expandable Palmaz-Schatz stent in the same patient, and to compare the results with the late angiographic outcome.Background. The immediate result of coronary balloon angioplasty is influenced by plastic deformation, primarily of the atherosclerotic plaque, and by elastic recoil, primarily of the less or nondiseased vessel circumference,Methods. The extent of elastic recoil was measured quantitatively as the difference between maximal balloon size and the resulting vessel diameter or cross-sectional area.Results. Analysis was pe…

AdultMalemedicine.medical_specialtymedicine.medical_treatmentCoronary balloon angioplastyCoronary DiseaseBalloonCoronary AngiographyElastic recoilRestenosisRecurrenceAngioplastyInternal medicinemedicineHumansAngioplasty Balloon CoronaryAgedAnalysis of Variancebusiness.industryStentEquipment DesignMiddle Agedmedicine.diseaseElasticityVessel diameterBalloon expandable stentCardiologyFemaleStentsbusinessCardiology and Cardiovascular MedicineFollow-Up StudiesJournal of the American College of Cardiology
researchProduct

The effect of spherical aberration on visual performance and refractive state for stimuli and tasks typical of night viewing

2018

Purpose: The aim of this work was to examine the impact of Seidel spherical aberration (SA) on optimum refractive state for detecting and discriminating small bright lights on a dark background. Methods: An adaptive-optics system was used to correct ocular aberrations of cyclopleged eyes and then systematically introduce five levels of Seidel SA for a 7-mm diameter pupil: 0, ± 0.18, and ± 0.36 diopters (D) mm−2. For each level of SA, subjects were required to detect one or resolve two points of light (0.54 arc min diameter) on a dark background. Refractive error was measured by adjusting stimulus vergence to minimize detection and resolution thresholds. Two other novel focusing tasks for si…

AdultOptics and PhotonicsOriginal articleCorneal Wavefront AberrationVisual AcuityStarburstDiameter pupilRefraction Ocular050105 experimental psychology03 medical and health sciences0302 clinical medicinelcsh:OphthalmologyError refractivoVisión nocturnaAberración esféricalcsh:QC350-467Humans0501 psychology and cognitive sciencesSpherical aberrationNight visionPhysicsResoluciónRefractive error05 social sciencesMiddle AgedRefractive ErrorsDetecciónDetectionlcsh:RE1-994030221 ophthalmology & optometryResolutionHumanitieslcsh:Optics. LightPhotic StimulationOptometryJournal of Optometry
researchProduct

Risk of aortic dissection in patients with ascending aorta aneurysm: a new biological, morphological, and biomechanical network behind the aortic dia…

2020

Thoracic aortic aneurysm represents a deadly condition, particularly when it evolves into rupture and dissection. Proper surgical timing is the key to positively influencing the survival of patients with this pathology. According to the most recent guidelines, ascending aorta size ≥ 55 mm and a rate of growth ≥ 0.5 cm per year are the most important factors for surgical indication. Nevertheless, a lot of evidence show that aortic ruptures and dissections might occur also in small size ascending aorta. In this review, we sought to analyze a new biological and morphological network behind the aortic diameter that need to be considered in order to identify the portion of patients with thoracic…

Aortic dissectionSettore MED/23business.industrymedicineIn patientAnatomyAscending aorta aneurysmAortic diameterCardiology and Cardiovascular Medicinemedicine.diseasebusinessAscending aorta aneurysm ascending aorta size aortic dissection genetic risk factors morphological aspects surgical indication for aortic repair
researchProduct

Analyzing the Correlation of Classical and Community-aware Centrality Measures in Complex Networks

2021

International audience; Identifying influential nodes in social networks is a fundamental issue. Indeed, it has many applications, such as inhibiting epidemic spreading, accelerating information diffusion, preventing terrorist attacks, and much more. Classically, centrality measures quantify the node's importance based on various topological properties of the network, such as Degree and Betweenness. Nonetheless, these measures are agnostic of the community structure, although it is a ubiquitous characteristic encountered in many real-world networks. To overcome this drawback, there is a growing trend to design so-called community-aware centrality measures. Although several works investigate…

AssortativityTransitivityEfficiency) and nine mesoscopic topological features (MixingAverage Distance[INFO.INFO-SI] Computer Science [cs]/Social and Information Networks [cs.SI]Density[INFO.INFO-LG] Computer Science [cs]/Machine Learning [cs.LG][INFO] Computer Science [cs][INFO.INFO-SI]Computer Science [cs]/Social and Information Networks [cs.SI]Diameter[INFO.INFO-LG]Computer Science [cs]/Machine Learning [cs.LG]Influential NodesCentrality Measures[INFO]Computer Science [cs]Community StructureComputingMilieux_MISCELLANEOUS
researchProduct

The clustering of galaxies in the SDSS-III Baryon Oscillation Spectroscopic Survey: Baryon Acoustic Oscillations in the Data Release 10 and 11 galaxy…

2014

We present a one per cent measurement of the cosmic distance scale from the detections of the baryon acoustic oscillations in the clustering of galaxies from the Baryon Oscillation Spectroscopic Survey (BOSS), which is part of the Sloan Digital Sky Survey III (SDSS-III). Our results come from the Data Release 11 (DR11) sample, containing nearly one million galaxies and covering approximately $8\,500$ square degrees and the redshift range $0.2<z<0.7$. We also compare these results with those from the publicly released DR9 and DR10 samples. Assuming a concordance $\Lambda$CDM cosmological model, the DR11 sample covers a volume of 13\,Gpc${}^3$ and is the largest region of the Universe ever su…

AstrofísicaCosmology and GravitationCosmology and Nongalactic Astrophysics (astro-ph.CO)[SDU.ASTR.CO]Sciences of the Universe [physics]/Astrophysics [astro-ph]/Cosmology and Extra-Galactic Astrophysics [astro-ph.CO]Cosmic microwave backgroundDark matterFOS: Physical sciencesAstrophysicsAstrophysics::Cosmology and Extragalactic Astrophysicsdistance scaleAstrophysics01 natural sciencesObservacions astronòmiques0103 physical sciencesQB Astronomycosmological parametersdark energy010303 astronomy & astrophysicsQCSTFCAstrophysics::Galaxy AstrophysicsQBPhysics/dk/atira/pure/core/subjects/cosmologyCosmologia010308 nuclear & particles physicsAngular diameter distanceAstrophysics::Instrumentation and Methods for AstrophysicsSpectral densityRCUKAstronomy and AstrophysicsEspectroscòpia de microonesGalaxyRedshiftobservations [cosmology]CosmologyBaryonQC Physics13. Climate actionSpace and Planetary ScienceMicrowave spectroscopyBaryon acoustic oscillationslarge-scale structure of UniverseAstrophysics - Cosmology and Nongalactic AstrophysicsAstronomical observations
researchProduct

VLBA observations of a rare multiple quasar imaging event caused by refraction in the interstellar medium

2013

We report on the first detection of the theoretically-predicted rare phenomenon of multiple parsec-scale imaging of an active galactic nucleus induced by refractive effects due to localized foreground electron density enhancements, e.g., in an AU-scale plasma lens(es) in the ionized component of the Galactic interstellar medium. We detected multiple imaging in the low galactic latitude (b=-2 deg) quasar 2023+335 from the 15.4 GHz MOJAVE observations when the source was undergoing an ESE. While the parsec-scale jet of the source normally extends along PA -20 deg, in the 28 May 2009 and 23 July 2009 images a highly significant multi-component pattern of secondary images is stretched out nearl…

AstrofísicaProper motionActive galactic nucleusCosmology and Nongalactic Astrophysics (astro-ph.CO)Astrophysics::High Energy Astrophysical PhenomenaFOS: Physical sciencesAstrophysicsAstrophysics::Cosmology and Extragalactic Astrophysics01 natural sciencesAngular diameter0103 physical sciencesVery-long-baseline interferometry010303 astronomy & astrophysicsAstrophysics::Galaxy AstrophysicsLine (formation)PhysicsHigh Energy Astrophysical Phenomena (astro-ph.HE)010308 nuclear & particles physicsScatteringAstronomy and AstrophysicsQuasarInterstellar mediumSpace and Planetary ScienceAstronomiaAstrophysics - High Energy Astrophysical PhenomenaAstrophysics - Cosmology and Nongalactic Astrophysics
researchProduct

Two properties of Müntz spaces

2017

Abstract We show that Müntz spaces, as subspaces of C[0, 1], contain asymptotically isometric copies of c0 and that their dual spaces are octahedral.

Asymptotically isometric copy of c0General Mathematicslcsh:Mathematics010102 general mathematicsMuntz metallcsh:QA1-93901 natural sciences010101 applied mathematicsMüntz spaceDiameter 2 propertiesCalculusPhysics::Atomic and Molecular ClustersOctahedral space0101 mathematicsMathematicsDemonstratio Mathematica
researchProduct

High-frequency rotational ablation following failed percutaneous transluminal coronary angioplasty.

1994

Percutaneous transluminal coronary angioplasty (PTCA) failed in 29 of 1,150 patients (2.5%) after successful passage of the guide wire. The reasons for failure were inability to pass the lesion with a balloon in 28 patients and inability to dilate the lesion in 1 patient. In these patients (15 stenoses and 14 chronic occlusions) rotational ablation was performed. We were able to pass the burr through the lesion in all of them, resulting in a reduction of diameter stenosis from 87 +/- 15 to 51 +/- 18%. Rotational ablation alone was initially successful (stenoses reduction > 20% and residual stenoses < 50%) in 15 of 29 (52%) patients. Additional PTCA was performed in 21 of 29 (72%) patients, …

Atherectomy CoronaryMalemedicine.medical_specialtyPercutaneous transluminal coronary angioplastyRotational ablationCoronary Artery DiseaseBalloonCoronary AngiographyLesionRecurrenceInternal medicinemedicineHumansMajor complicationTreatment FailureAngioplasty Balloon Coronarybusiness.industryMiddle AgedCoronary heart diseaseSurgeryDiameter stenosisCardiologyFemalemedicine.symptomCardiology and Cardiovascular MedicinebusinessCatheterization and cardiovascular diagnosis
researchProduct