Search results for "Diameter"
showing 10 items of 189 documents
Effect of Kernels Used for the Reconstruction of MDCT Datasets on the Semi-Automated Segmentation and Volumetry of Liver Lesions
2014
Purpose: To evaluate the effect of different reconstruction kernels on the semi-automated segmentation of liver lesions in MDCT. Materials and Methods: A total 62 liver lesions were measured by three independent radiologists with the semi-automated segmentation software Oncology-Prototype (Fraunhofer MEVIS, Siemens Healthcare, Germany) using MDCT datasets (3-mm slice thickness, 2-mm increment) reconstructed with standard, soft and detailed kernels (Philips B, A and D). To ensure objective measurements, only lesions with satisfactory initial segmentation were included, and manual correction was not used. The effective diameter and volume were recorded for each lesion. Segmentation in the sof…
Relationship between aortic root size and glomerular filtration rate in hypertensive patients
2016
OBJECTIVE: Recent studies suggest that enlarged aortic root diameter (ARD) may predict cardiovascular events in absence of aneurysmatic alterations. Little is known about the influence of renal function on ARD. Our study was aimed to assess the relationships between glomerular filtration rate (GFR) and ARD in hypertensive subjects. METHODS: We enrolled 611 hypertensive individuals (mean age: 52 ± 15 years; men 63%). ARD was measured by echocardiography at the level of Valsalva's sinuses using M-mode tracings. It was considered as absolute measure, normalized to body surface area (ARD/BSA) and indexed to height (ARD/H). GFR was estimated by the Chronic Kidney Disease Epidemiology Collaborati…
Quantitative analysis of elastic recoil after balloon angioplasty and after intracoronary implantation of balloon-expandable Palmaz-Schatz stents.
1993
AbstractObjectives. The purpose of this study was to measure elastic recoil from sequential angiograms after balloon angioplasty and after implantation of a balloon-expandable Palmaz-Schatz stent in the same patient, and to compare the results with the late angiographic outcome.Background. The immediate result of coronary balloon angioplasty is influenced by plastic deformation, primarily of the atherosclerotic plaque, and by elastic recoil, primarily of the less or nondiseased vessel circumference,Methods. The extent of elastic recoil was measured quantitatively as the difference between maximal balloon size and the resulting vessel diameter or cross-sectional area.Results. Analysis was pe…
The effect of spherical aberration on visual performance and refractive state for stimuli and tasks typical of night viewing
2018
Purpose: The aim of this work was to examine the impact of Seidel spherical aberration (SA) on optimum refractive state for detecting and discriminating small bright lights on a dark background. Methods: An adaptive-optics system was used to correct ocular aberrations of cyclopleged eyes and then systematically introduce five levels of Seidel SA for a 7-mm diameter pupil: 0, ± 0.18, and ± 0.36 diopters (D) mm−2. For each level of SA, subjects were required to detect one or resolve two points of light (0.54 arc min diameter) on a dark background. Refractive error was measured by adjusting stimulus vergence to minimize detection and resolution thresholds. Two other novel focusing tasks for si…
Risk of aortic dissection in patients with ascending aorta aneurysm: a new biological, morphological, and biomechanical network behind the aortic dia…
2020
Thoracic aortic aneurysm represents a deadly condition, particularly when it evolves into rupture and dissection. Proper surgical timing is the key to positively influencing the survival of patients with this pathology. According to the most recent guidelines, ascending aorta size ≥ 55 mm and a rate of growth ≥ 0.5 cm per year are the most important factors for surgical indication. Nevertheless, a lot of evidence show that aortic ruptures and dissections might occur also in small size ascending aorta. In this review, we sought to analyze a new biological and morphological network behind the aortic diameter that need to be considered in order to identify the portion of patients with thoracic…
Analyzing the Correlation of Classical and Community-aware Centrality Measures in Complex Networks
2021
International audience; Identifying influential nodes in social networks is a fundamental issue. Indeed, it has many applications, such as inhibiting epidemic spreading, accelerating information diffusion, preventing terrorist attacks, and much more. Classically, centrality measures quantify the node's importance based on various topological properties of the network, such as Degree and Betweenness. Nonetheless, these measures are agnostic of the community structure, although it is a ubiquitous characteristic encountered in many real-world networks. To overcome this drawback, there is a growing trend to design so-called community-aware centrality measures. Although several works investigate…
The clustering of galaxies in the SDSS-III Baryon Oscillation Spectroscopic Survey: Baryon Acoustic Oscillations in the Data Release 10 and 11 galaxy…
2014
We present a one per cent measurement of the cosmic distance scale from the detections of the baryon acoustic oscillations in the clustering of galaxies from the Baryon Oscillation Spectroscopic Survey (BOSS), which is part of the Sloan Digital Sky Survey III (SDSS-III). Our results come from the Data Release 11 (DR11) sample, containing nearly one million galaxies and covering approximately $8\,500$ square degrees and the redshift range $0.2<z<0.7$. We also compare these results with those from the publicly released DR9 and DR10 samples. Assuming a concordance $\Lambda$CDM cosmological model, the DR11 sample covers a volume of 13\,Gpc${}^3$ and is the largest region of the Universe ever su…
VLBA observations of a rare multiple quasar imaging event caused by refraction in the interstellar medium
2013
We report on the first detection of the theoretically-predicted rare phenomenon of multiple parsec-scale imaging of an active galactic nucleus induced by refractive effects due to localized foreground electron density enhancements, e.g., in an AU-scale plasma lens(es) in the ionized component of the Galactic interstellar medium. We detected multiple imaging in the low galactic latitude (b=-2 deg) quasar 2023+335 from the 15.4 GHz MOJAVE observations when the source was undergoing an ESE. While the parsec-scale jet of the source normally extends along PA -20 deg, in the 28 May 2009 and 23 July 2009 images a highly significant multi-component pattern of secondary images is stretched out nearl…
Two properties of Müntz spaces
2017
Abstract We show that Müntz spaces, as subspaces of C[0, 1], contain asymptotically isometric copies of c0 and that their dual spaces are octahedral.
High-frequency rotational ablation following failed percutaneous transluminal coronary angioplasty.
1994
Percutaneous transluminal coronary angioplasty (PTCA) failed in 29 of 1,150 patients (2.5%) after successful passage of the guide wire. The reasons for failure were inability to pass the lesion with a balloon in 28 patients and inability to dilate the lesion in 1 patient. In these patients (15 stenoses and 14 chronic occlusions) rotational ablation was performed. We were able to pass the burr through the lesion in all of them, resulting in a reduction of diameter stenosis from 87 +/- 15 to 51 +/- 18%. Rotational ablation alone was initially successful (stenoses reduction > 20% and residual stenoses < 50%) in 15 of 29 (52%) patients. Additional PTCA was performed in 21 of 29 (72%) patients, …