Search results for "Diameter"

showing 10 items of 189 documents

Influence of vessel dilatation on restenosis after successful percutaneous transluminal coronary angioplasty.

1996

The aim of this study was to evaluate the influence of vessel dilation on restenosis after successful percutaneous transluminal coronary angioplasty (PTCA) on the basis of quantitative angiographic analysis. To have the best comparison possible, we restrospectively studied a homogenous series of patients from the early 1980s treated according to a standardized PTCA procedure. The study group consisted of 86 patients with stable angina pectoris and single-vessel disease, all of whom underwent successful PTCA for a short concentric lesion in proximal vessel parts. The overall restenosis rate was 27%. Angiographically measured balloon size remained below specifications. The size of the inflate…

Malemedicine.medical_specialtyPercutaneous transluminal coronary angioplastyLumen (anatomy)Coronary DiseaseBalloonLesionRestenosisRecurrenceInternal medicinemedicineHumansIn patientAngioplasty Balloon CoronaryAgedbusiness.industryMiddle Agedmedicine.diseaseVessel diameterTreatment OutcomeCardiologyFemalemedicine.symptomCardiology and Cardiovascular MedicineComplicationbusinessAmerican heart journal
researchProduct

A novel 3-d reconstruction system for the assessment of bifurcation lesions treated by the mini-crush technique.

2010

Background: Conventional two-dimensional angiography lacks the ability to properly image the true bifurcation geometry, and its percutaneous coronary intervention-induced changes in the clinical setting. Methods and Results: A novel three-dimensional reconstruction system was investigated by retrospectively analyzing 39 lesions in 35 consecutive patients with coronary bifurcation disease treated with the mini-crush technique. At baseline, significant correlations were proved between two- and three-dimensional systems in terms of either reference vessel diameter (R 2 = 0.68 and 0.29 for main and side branches, respectively), minimum lumen diameter (R 2 = 0.73 and 0.36), stenosis diameter (R …

Malemedicine.medical_specialtyPercutaneousTime Factorsmedicine.medical_treatmentStatistics as TopicCoronary Artery DiseaseCoronary AngiographyStatistics NonparametricVentricular Function LeftLesionCoronary RestenosisImaging Three-DimensionalmedicineHumansRadiology Nuclear Medicine and imagingAngioplasty Balloon CoronaryCoronary Artery BypassBifurcationRetrospective StudiesAnalysis of Variancemedicine.diagnostic_testMini-Crush Technique.business.industryStentStroke VolumeMiddle Agedmedicine.diseaseCoronary VesselsLumen DiameterVessel diameterStenosisAngiographyBifurcationFemaleRadiologymedicine.symptomCardiology and Cardiovascular MedicinebusinessAlgorithmsSoftwareJournal of interventional cardiology
researchProduct

Effect of the height-to-diameter ratio on the mass transfer and mixing performance of a biotrickling filter

2017

BACKGROUND Biotrickling filters (BTFs) are among the most widely used biological technologies for air pollution control. The pollutant removal rate in BTFs relies to a large extent on its gas–liquid mass transfer performance. Therefore, knowledge of the design parameters affecting the mass transfer and mixing performance of full-scale BTFs is of paramount importance. RESULTS This work showed that the height-to-diameter (H/D) ratio is an important parameter in the design of BTFs devoted to air pollution control. The H/D ratio significantly affected the mass transfer and mixing performance of the BTF with and without additional stirring in the holding tank. It was observed that under the same…

Mass transfer coefficientWork (thermodynamics)Materials scienceRenewable Energy Sustainability and the EnvironmentGeneral Chemical EngineeringOrganic ChemistryMixing (process engineering)Environmental engineering02 engineering and technologyMechanics010501 environmental sciences021001 nanoscience & nanotechnology01 natural sciencesPollutionInorganic ChemistryDiameter ratioFilter (large eddy simulation)Fuel TechnologyLiquid velocityMass transferHolding tank0210 nano-technologyWaste Management and Disposal0105 earth and related environmental sciencesBiotechnologyJournal of Chemical Technology & Biotechnology
researchProduct

Using Dynamic Light Scattering for Monitoring the Size of the Suspended Particles in Wastewater

2019

Abstract A coherent light scattering experiment on wastewater samples extracted from several stages of water processing within a wastewater processing plant was carried out. The samples were allowed to sediment while they were the subject of a Dynamic Light Scattering (DLS) measurement. The recorded time series were processed using an Artificial Neural Network based DLS procedure to produce the average diameter of the particles in suspension. The method, using a single physical procedure for monitoring the variation of the average diameter in time, indicates the dominant type of suspensions in water.

Materials scienceAverage diameterEcologyScatteringSuspended particlesWater processingSediment010501 environmental sciences01 natural sciencescoherent light scatteringSuspension (chemistry)010309 opticsWastewaterDynamic light scattering0103 physical sciencesBiological systemdynamic light scattering (dls)wastewaterartificial neural networkQH540-549.50105 earth and related environmental sciencesTransylvanian Review of Systematical and Ecological Research
researchProduct

Evolution of grain-size distribution of pumice sands in 1-D compression

2016

Abstract Crushing is one of the micromechanisms that govern the mechanical behaviour of sands at medium-high stresses. It depends on mineralogy, form and strength of single particle, mean stress level, coordination number, time, etc.. It causes changes of grain-size distribution, porosity, number and type of grain contacts, fabric, structure of the material, etc.. Results of an experimental research on the crushing of pumice sands compressed under 1-D conditions to vertical effective stresses σ′v up to 100MPa are reported here. They show marked crushing already at σ′v of about 200kPa. The evolution of the grain-size distribution can be represented by ΔDi= h/(K(1+C exp(–hlgσ′v))) in which ΔD…

Materials scienceCoordination numbercharacteristic diameterone-dimensional compression0211 other engineering and technologies02 engineering and technologyGranular materialBreakagePumice021105 building & constructionevolutionfractals.Composite materialPorosityEngineering(all)021101 geological & geomatics engineeringGranular materialGranular materialscharacteristic diametersSettore ICAR/07 - GeotecnicaGranular materials; crushing; evolution; grading; characteristic diameters; one-dimensional compression; fractals.crushinggradingGeneral MedicineExperimental researchMean stressfractalsParticle-size distribution
researchProduct

Geometric Analysis of Type B Aortic Dissections Shows Aortic Remodeling After Intervention Using Multilayer Stents

2020

Recently, multilayer stents for type B aortic dissections (TBAD) have been proposed to decrease false lumen flow, increase and streamline true lumen flow, and retain branch vessel patency. We aimed to provide a protocol with standardized techniques to investigate aortic remodeling of TBAD by multilayer flow modulators (MFM) in static geometric and hemodynamic analyses. Combining existing literature and new insights, a standardized protocol was designed. Using pre- and postoperative CT scans, geometric models were constructed, lumen dimensions were calculated, computational fluid dynamics (CFD) models were composed, and velocity and pressures were calculated. Sixteen TBAD cases treated with …

Materials scienceGeometric analysisHemodynamics3d modelcomputational fluid dynamics030204 cardiovascular system & hematologylcsh:TechnologyArticle03 medical and health sciences0302 clinical medicinemedicineMedical imagingGeneral Materials Scienceaortic dissectionlcsh:Microscopylcsh:QC120-168.85Aortic dissectionlcsh:QH201-278.5multilayer flow modulatorlcsh:Tmedicine.diseaseaortic remodelinggeometric analysisLumen DiameterFlow velocitylcsh:TA1-2040lcsh:Descriptive and experimental mechanicslcsh:Electrical engineering. Electronics. Nuclear engineeringlcsh:Engineering (General). Civil engineering (General)lcsh:TK1-9971030217 neurology & neurosurgeryBiomedical engineeringLumen (unit)Materials
researchProduct

Highly sensitive optical hydrogen sensor using circular Pd-coated singlemode tapered fibre

2001

A novel optical hydrogen sensor, based on the absorption change of the evanescent fields in a circular Pd-coated singlemode tapered fibre is presented. The proposed sensor is polarisation independent and its sensitivity is adjustable by means of the taper diameter, interaction length, and/or light wavelength. A simple light transmission measurement setup is used to test the sensor. The sensor is suitable for the detection of low hydrogen concentrations with high sensitivity and fast time response. Transmission changes as high as 60% are demonstrated.

Materials scienceHydrogenbusiness.industryResponse timechemistry.chemical_elementÒpticaHydrogen sensorSubwavelength-diameter optical fibreWavelengthOpticsTransmission (telecommunications)chemistrysense organsElectrical and Electronic EngineeringbusinessAbsorption (electromagnetic radiation)Sensitivity (electronics)
researchProduct

Optical power distribution of refractive and aspheric multifocal contact lenses: Effect of pupil size

2015

Abstract Purpose To evaluate the power profile within the optic zone of different designs of multifocal contact lenses (CLs) and to analyze how the effect of pupil size could impact on their optical performance. Methods The optical power distribution within the optic zones of multifocal CLs was measured by the Nimo TR1504 (LAMBDA-X, Belgium). The multifocal CLs under study were the Acuvue Bifocal, the Acuvue Oasys for Presbyopia, the PureVision Multifocal and the PureVision 2 for Presbyopia. Each design was considered in all their available addition powers. All lenses had a nominal power of −3.0D. At the same time, three lenses of each model were considered and five consecutive readings of …

Materials scienceLightContact LensesPupil diameterIrisOptical powerlaw.inventionCLs upper limitsOpticslawmedicineHumansScattering Radiationbusiness.industryPupil sizeEquipment DesignPresbyopiaGeneral MedicinePresbyopiamedicine.diseaseRefractionEquipment Failure AnalysisLens (optics)RefractometryOphthalmologybusinessOptometryContact Lens and Anterior Eye
researchProduct

Simulation of Young’s moduli for hexagonal ZnO [0 0 0 1]-oriented nanowires: first principles and molecular mechanical calculations

2017

The authors thank A Gulans, B Polyakov and S Vlassov for stimulating discussions. This study has been supported by the ERA.Net RUS Plus project No. 237 Watersplit. AB, RE and SL acknowledge the financial support by the Russian Foundation for Basic Research (Grant No. 17-03-00130-a) and the assistance of the Saint Petersburg State University Computer Center in the accomplishment of high-performance computations.

Materials sciencePolymers and PlasticsComputationAb initioNanowireModuluschemistry.chemical_elementNanotechnology02 engineering and technologyZinc010402 general chemistry01 natural sciencesQuantum chemistryBiomaterials:NATURAL SCIENCES:Physics [Research Subject Categories]ab initio hybrid PBE0 calculations (CRYSTAL code)force field calculations using pairwise potentials (GULP code)Condensed matter physicsMetals and Alloysnanowire Young’s modulus YNW and its dependence on diameter dNWwurtzite-structured ZnO (bulk and nanowires)021001 nanoscience & nanotechnologyCompression (physics)Piezoelectricity0104 chemical sciencesSurfaces Coatings and FilmsElectronic Optical and Magnetic Materialschemistry0210 nano-technologyMaterials Research Express
researchProduct

Actively mode-locked fibre ring laser based on in-fibre acousto-optic amplitude modulation

2011

Recent advances in the development of all-fibre amplitude modulators have led to the implementation of a series of different actively mode-locked fibre lasers [1–4]. In-fibre acousto-optic modulation based on intermodal coupling induced my a standing flexural acoustic wave permits the implementation of broad bandwidth (1.5 nm), high modulation depth (0.72), low-insertion-loss (0.75 dB) all-fibre amplitude modulators that operate in the MHz frequency range. The experimental characterization of a laser with the configuration depicted in Fig. 1 (a) as a function of the radio frequency voltage that controls the modulator (see Fig. 1 (b)), the length of the Erbium doped fibre (EDF), and the opti…

Materials sciencebusiness.industryRing laserFibre optic gyroscopeLaserlaw.inventionSubwavelength-diameter optical fibreAmplitude modulationOpticsMode-lockingFiber Bragg gratinglawFiber laserOptoelectronicsbusiness2011 Conference on Lasers and Electro-Optics Europe and 12th European Quantum Electronics Conference (CLEO EUROPE/EQEC)
researchProduct