Search results for "Diol"

showing 10 items of 11756 documents

Absence of cardiovascular autonomic dysfunction and vagal pancreatic impairment in idiopathic achalasia of the oesophagus

2007

Abstract  Extra-oesophageal autonomic dysfunction in idiopathic achalasia is not well documented, due to contradictory results reported. We aimed to study the cardiovascular and pancreatic autonomic function in patients with idiopathic achalasia. Thirty patients with idiopathic achalasia (16M/14F; 34.5 ± 10.8 years) and 30 healthy volunteers (13M/17F; 34.8 ± 10.7 years) were prospectively studied. Age >60 years and conditions affecting results of autonomic evaluation were excluded. Both groups underwent the sham feeding test and plasmatic levels of pancreatic polypeptide (PP) were determined by radioimmunoassay (basal, at 5, 10, 20 and 30 min). Cardiovascular parasympathetic (deep breathing…

AdultMaleAutonomic functionmedicine.medical_specialtyAdolescentPhysiologyDiaphragmatic breathingAchalasiaAutonomic Nervous SystemPancreatic PolypeptideEatingEsophagusInternal medicinemedicineHumansPancreatic polypeptideEndocrine and Autonomic Systemsbusiness.industryGastroenterologyVagus NerveRadioimmunoassayMiddle Agedmedicine.diseaseSham feedingEsophageal AchalasiaBlood pressureTasteAnesthesiaCardiologyMasticationFemaleIdiopathic achalasiabusinessNeurogastroenterology & Motility
researchProduct

Real-time ultrasound of normal adrenal glands and small tumors.

1984

The adrenals were studied prospectively with real-time ultrasound in a series of 60 healthy individuals and 13 patients with small adrenal masses sized 8-20 mm in diameter. In only one of the 60 healthy subjects was a normal adrenal gland delineated as a distinct hypoechoic structure. In all other instances only the highly echogenic suprarenal fat could be displayed. Visualization of small tumors was successful in 12 of 13 patients. The suprarenal area and small lesions were best demonstrated by a lateral intercostal approach using longitudinal and transverse scanning planes. The best access was through the 9th/10th intercostal space at the junction with the anterior and middle axillary lin…

AdultMaleAxillary linesAdrenal Gland NeoplasmsReal time ultrasoundPheochromocytomaAdrenal GlandsMedicineHumansRadiology Nuclear Medicine and imagingUltrasonicsProspective StudiesSmall tumorsAldosteroneUltrasonographyAdrenal Hyperplasia Congenitalbusiness.industryAdrenal glandUltrasoundHealthy subjectsEchogenicityAnatomyAdrenal Cortex Neoplasmsmedicine.anatomical_structureFemaleIntercostal spacebusinessJournal of clinical ultrasound : JCU
researchProduct

Evaluation of the apparent diffusion coefficient in patients with recurrent glioblastoma under treatment with bevacizumab with radiographic pseudores…

2017

Abstract Background Response Assessment in Neuro-Oncology Criteria (RANO), are used to asses response to first-line treatment of glioblastoma (GBM). Differentiation between response and pseudoresponse under treatment with Bevacizumab (BVZ) remains challenging. This study evaluates ADC changes in patients with radiographic pseudoresponse under treatment with (BVZ). Methods Patients (n = 40) with recurrent GBM under-treatment with BVZ underwent MRI before, two and four months after treatment with BVZ. In patients with radiological pseudoresponse (n = 11), ADC analyses were performed. Areas with decreasing T1 contrast enhancement (CE) and FLAIR signal decrease were manually selected and compar…

AdultMaleBevacizumabRadiographyPseudoresponseFluid-attenuated inversion recovery030218 nuclear medicine & medical imaging03 medical and health sciencesAntineoplastic Agents Immunological0302 clinical medicineImage Interpretation Computer-AssistedmedicineHumansEffective diffusion coefficientRadiology Nuclear Medicine and imagingIn patientAgedRadiological and Ultrasound TechnologyBrain Neoplasmsbusiness.industryMiddle Agedmedicine.diseaseHyperintensityBevacizumabbody regionsDiffusion Magnetic Resonance ImagingTreatment OutcomeFemaleNeurology (clinical)Neoplasm Recurrence LocalGlioblastomabusinessNuclear medicine030217 neurology & neurosurgerymedicine.drugGlioblastomaJournal of Neuroradiology
researchProduct

COMPARISON OF T-1 ESTIMATION TECHNIQUES IN CARDIAC MRI

1994

International audience; Abstract: We have shown that the use of a simple combination of inversion recovery/spin-echo (IR/SE) sequences provides undeniably superior precision in quantitative in vivo myocardium T-1 estimation than the standard multiple spin-echo approach. On a group of 25 healthy subjects, the T-1 dispersion was, respectively, 3.8% for the IR/SE combination and 19.6% for the best SE pair combination. Moreover, repeated measurements were carried out on seven of the volunteers in order to assess T-1 reproducibility. The mean intra-individual T-1 precision was found to be 2.8% for the IR/SE pair and 20.0% for the best SE pair. The in vivo imaging work was supported and corrobora…

AdultMaleBiomedical EngineeringBiophysicsInversion recovery030204 cardiovascular system & hematologyTISSUE CHARACTERIZATION030218 nuclear medicine & medical imaging03 medical and health sciences0302 clinical medicineNuclear magnetic resonanceCARDIAC MRIQUALITY CONTROL[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansRadiology Nuclear Medicine and imagingMathematicsReproducibility[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingHealthy subjectsHeartTissue characterizationT-1Magnetic Resonance ImagingFemalePreclinical imaging
researchProduct

Inhibition of thromboxane biosynthesis and platelet function by simvastatin in type IIa hypercholesterolemia

1995

Abstract Thromboxane A 2 (TXA 2 ) biosynthesis is enhanced in the majority of patients with type IIa hypercholesterolemia. Because simvastatin (a 3-hydroxy-3-methylglutaryl coenzyme A reductase inhibitor) was previously shown to reduce platelet aggregation and TXB 2 production ex vivo, we investigated TXA 2 biosynthesis and platelet function in 24 patients with type IIa hypercholesterolemia randomized to receive in a double-blind fashion simvastatin (20 mg/d) or placebo for 3 months. The urinary excretion of 11-dehydro-TXB 2 , largely a reflection of platelet TXA 2 production in vivo, was measured by a previously validated radioimmunoassay technique. Blood lipid levels and urinary 11-dehyd…

AdultMaleBlood lipoproteinSimvastatinmedicine.medical_specialtyPlatelet AggregationApolipoprotein BThromboxaneHypercholesterolemiaBlood lipidsThromboxane A2chemistry.chemical_compoundThromboxane A2Double-Blind MethodInternal medicinemedicineHumansPlateletLovastatinAgedbiologyChemistryCholesterolAnticholesteremic AgentsMiddle AgedLipid MetabolismCholesterolEndocrinologySimvastatinbiology.proteinFemalelipids (amino acids peptides and proteins)Cardiology and Cardiovascular MedicinePlatelet Aggregation Inhibitorsmedicine.drug
researchProduct

Physician attitudes to blood pressure control

2011

OBJECTIVES: The Supporting Hypertension Awareness and Research Europe-wide (SHARE) physician survey aimed to qualify the key challenges that physicians face when trying to get patients to blood pressure (BP) goal. METHODS: The SHARE survey was open to physicians involved in the treatment of patients with hypertension, was anonymous, and was designed to take 15 min to complete. The survey included 45 questions covering physicians' demographic information, views on the BP targets recommended by the European Society of Hypertension-European Society of Cardiology guidelines, opinions on acceptable levels of BP control, and perceptions about the challenges associated with getting patients to BP …

AdultMaleBlood pressure controlHealth Knowledge Attitudes Practicemedicine.medical_specialtyBiomedical ResearchAttitude of Health PersonnelPhysiologyElevated bpMEDLINEBlood PressureRisk AssessmentPhysiciansSurveys and QuestionnairesInternal MedicineHumansMedicinePractice Patterns Physicians'Antihypertensive Agentsbusiness.industryGuideline adherenceGuidelineAwarenessMiddle AgedHealth SurveysEuropeBlood pressureCardiovascular DiseasesPhysician surveyFamily medicineHypertensionFemaleGuideline AdherenceCardiology and Cardiovascular MedicinebusinessRisk assessmentJournal of Hypertension
researchProduct

Tc-99m HMPAO Cerebral Scintigraphy A Reliable, Noninvaslve Method for Determination of Brain Death

1993

To determine the usefulness of cerebral blood flow imaging for the diagnosis of brain death, 4 female and 12 male patients, aged 19 to 69 years and suffering from various intracranial lesions, were studied. In addition to neurologic examination, electroencephalographic recording, and cerebral angiography, tomographic brain scintigraphy was performed using a SPECT system with a LEAP collimator after the intravenous administration of 555 MBq Tc-99m HMPAO. The radioisotopic scanning procedure revealed no intracranial perfusion in 14 of the 16 patients. Only minimal cerebellar blood flow was seen in one patient. In another, residual right-sided supratentorial flow was initially present but abse…

AdultMaleBrain DeathHemodynamicsScintigraphyTechnetium Tc 99m ExametazimeOximesmedicineHumansRadiology Nuclear Medicine and imagingRadionuclide ImagingAgedmedicine.diagnostic_testbusiness.industryBrainOrganotechnetium CompoundsGeneral MedicineBlood flowMiddle AgedCerebral blood flowCerebrovascular CirculationAngiographyTechnetium Tc 99m ExametazimeFemaleNuclear medicinebusinessPerfusionCerebral angiographyClinical Nuclear Medicine
researchProduct

Contrast-enhanced transcranial Doppler ultrasonography in the diagnosis of brain death

2013

The diagnosis of brain death (BD) is based on clinical criteria including deep coma, brain stem areflexia and apnoea. Depending on different local guidelines, confirmatory technical tests are sometimes mandatory.1 Since the 1990s, transcranial Doppler sonography (TCD) has found its place in these circumstances and fulfils most of the criteria of an ‘ideal test’ in confirming BD. To confirm intracranial circulatory arrest (CA) with Doppler sonography, typical flow patterns must be recorded in bilateral intracranial and extracranial brain-supplying arteries.2 A completely absent intracranial flow signal is not a reliable sign to determine CA because this can be due to transmission problems. I…

AdultMaleBrain Deathmedicine.medical_specialtyAdolescentSystoleUltrasonography Doppler TranscranialContrast MediaPhysical examinationYoung AdultEvoked Potentials SomatosensoryIntensive careTemporal bonemedicineHumansChildAgedAged 80 and overBrain deadMicrobubblesmedicine.diagnostic_testbusiness.industryHead injuryUltrasoundElectroencephalographyMiddle Agedmedicine.diseaseTranscranial Doppler ultrasonographyPsychiatry and Mental healthDoppler sonographyCerebrovascular CirculationFemaleSurgeryNeurology (clinical)RadiologybusinessJournal of Neurology, Neurosurgery & Psychiatry
researchProduct

Differential impact of continuous theta-burst stimulation over left and right DLPFC on planning

2011

Most neuroimaging studies on planning report bilateral activations of the dorsolateral prefron- tal cortex (dlPFC). Recently, these concurrent activations of left and right dlPFC have been shown to dou- ble dissociate with different cognitive demands imposed by the planning task: Higher demands on the extraction of task-relevant information led to stronger activation in left dlPFC, whereas higher demands on the integration of interdependent information into a coherent action sequence entailed stronger activa- tion of right dlPFC. Here, we used continuous theta-burst stimulation (cTBS) to investigate the supposed causal structure-function mapping underlying this double dissociation. Two grou…

AdultMaleCTBSPrefrontal CortexPosterior parietal cortexStimulationbehavioral disciplines and activitiesFunctional LateralityLateralization of brain functionYoung AdultCognitionNeuroimagingParietal LobeCortex (anatomy)Reaction TimemedicineHumansRadiology Nuclear Medicine and imagingTheta RhythmPrefrontal cortexResearch ArticlesBrain MappingRadiological and Ultrasound TechnologyCognitionMagnetic Resonance ImagingTranscranial Magnetic Stimulationmedicine.anatomical_structureNeurologyFemaleNeurology (clinical)AnatomyPsychologyNeurosciencePsychomotor Performancepsychological phenomena and processesHuman Brain Mapping
researchProduct

Somatostatin-receptor scintigraphy in Graves' disease: reproducibility and variance of orbital activity.

2000

Somatostatin-receptor (SSTR) scintigraphy using the single photon emission computed tomography (SPECT) technique allows the assessment of orbital inflammation in patients with Graves' disease. Previous studies showed differences in orbital octreotide uptake already 4 hr after injection. In this study, analysis of inter-/intra-observer variance and reproducibility in the evaluation of orbital SPECT images was performed. First, SPECT data of one representative female patient with clinically active Graves' ophthalmopathy (GO), obtained 4 hr after intravenous injection of 110 MBq 111In-pentetreotide and processed by filtered backprojection, were analyzed. Transverse SPECT images were reconstruc…

AdultMaleCancer ResearchGraves' diseaseSingle-photon emission computed tomographyScintigraphyCorrelationSpearman–Brown prediction formulamedicineHumansRadiology Nuclear Medicine and imagingAgedPharmacologyObserver VariationTomography Emission-Computed Single-PhotonReproducibilitymedicine.diagnostic_testbusiness.industryIndium RadioisotopesReproducibility of ResultsGeneral MedicineVariance (accounting)Middle Agedmedicine.diseaseGraves DiseaseOncologyFemaleTomographybusinessNuclear medicineSomatostatinOrbitCancer biotherapyradiopharmaceuticals
researchProduct