Search results for "Discharge"
showing 10 items of 424 documents
Partial Discharge Detection Using a Spherical Electromagnetic Sensor
2019
The presence of a partial discharge phenomenon in an electrical apparatus is a warning signal that could determine the failure of the insulation system, terminating the service of the apparatus and/or the network. In this paper, an innovative partial discharge (PD) measurement instrument based on an antenna sensor is presented and analyzed. Being non-intrusive is one of the most relevant features of the sensor. The frequency response of the antenna sensor and the features to recognize different PD sources and automatically synchronize them with the supply voltage are described and discussed in details. The results show the performance of the instrument can make a fast and correct diagnosis …
Enhanced tonic GABAA inhibition in typical absence epilepsy
2009
The cellular mechanisms underlying typical absence seizures, which characterize various idiopathic generalized epilepsies, are not fully understood, but impaired γ-aminobutyric acid (GABA)-ergic inhibition remains an attractive hypothesis. In contrast, we show here that extrasynaptic GABAA receptor–dependent 'tonic' inhibition is increased in thalamocortical neurons from diverse genetic and pharmacological models of absence seizures. Increased tonic inhibition is due to compromised GABA uptake by the GABA transporter GAT-1 in the genetic models tested, and GAT-1 is crucial in governing seizure genesis. Extrasynaptic GABAA receptors are a requirement for seizures in two of the best character…
A study of capillary discharge lamps in Ar–Hg and Xe–Hg mixtures
2011
Low-pressure capillary discharge lamps in Ar–Hg and Xe–Hg mixtures are studied. The discharge size is 0.5 mm (500 µm) in radius. According to the literature, such types of plasma sources are classified as microplasmas. The studies include spectrally resolved optical measurements, tomographic reconstructions and numerical simulations using the collisional–radiative model for an Ar–Hg plasma. We discuss the problems of theoretical modelling and experimental diagnostics of microplasma sources. It is shown that the conventional collisional–radiative model, based on the assumption that transportation of atoms in the highly excited states can be neglected, has limitations in modelling a capillary…
Spatial Diagnostics of Hg/Ar and Hg/Xe Discharge Lamps by Means of Tomography
2011
In this work, the diagnostics using tomography in Hg/Xe and Hg/Ar capillary lamps is presented. First, the imaging of the lamps was performed using selected emission lines of mercury, argon and xenon in different operation conditions. Thus the tomographic reconstruction was made, to determine the spatial distribution of the emitting Hg and rare gas atoms. Significant differences of the distribution of the emitting atoms have been found in vertical and horizontal operation positions. The emitting mercury atoms in the state 73S1 were differently distributed within the lamp in the vertical and horizontal lamp positions. The radial profile has demonstrated a substantial depletion of the popula…
Estimation of the emission temperature of an electrodeless discharge lamp and determination of the oscillator strength for the I(2P3/2) 183.038 nm re…
2001
Abstract The 183.038 nm resonance absorption transition of I( 2 P 3/2 ) has been studied using a flash photolysis set-up for gas-phase chemistry and a radio frequency powered electrodeless discharge lamp filled with iodine. The dependence of self-absorption and self-reversal on iodine partial pressure in the discharge volume was measured. The optimum iodine partial pressure, with self-absorption minimized and acceptable intensity, is determined to be approximately 2.5×10 −3 mbar. A method is described to estimate the temperature of the emitting atoms using direct measurements of relative absorption at different absorber concentrations. This yields an emission temperature of 923±50 K. Using …
Adverse Clinical Events and Mortality During Hospitalization and 3 Months After Discharge in Cognitively Impaired Elderly Patients
2012
BACKGROUND: Controversial findings are reported on hospital outcome in cognitively impaired patients. The aim of this study was to explore mortality risk according to cognitive status during hospitalization and after 3 months in elderly patients. METHODS: Sixty-six internal medicine and geriatric wards in Italy participated in the "Registry Politerapie SIMI (REPOSI)" during 2010. Of the 1,380 in-patients, aged 65 and older enrolled, 1,201 were included. Cognition was evaluated with the Short Blessed Test (SBT). Logistic regression was used to evaluate the association of questionable and impaired cognition (according to SBT cutoff points) with mortality during hospitalization and at follow-u…
Global Coastal Permeability database (GCPdb)
2023
The Global Coastal Permeability Database contains both the input and output data of the Global Coastal Permeability Model developed by Tschaikowski et al. (2023) and available at DOI: 10.5281/zenodo.7845568. The model is implemented in R and calculates the coastal permeability for each shoreline segment of the global shoreline vector created by Sayre et al. (2019) with a 30-meter resolution and covering a spatial extent of 180.0°W to 180.0°E longitude and 60.8°S to 83.7°N latitude. The coastline is separated into three sections (A: coastal aquifer section, B: shoreline section, C: shallow section), and permeability values and ranges are provided for each section. Permeability values were de…
Study of a new direct current atmospheric pressure glow discharge in helium
2011
Abstract In this study a new DC-APGD operated in He was developed and characterized. The discharge is operated at 0.9 kV and about 25–35 mA and at a gas flow of 100 ml/min. The source was spectroscopically studied and parameters such as the rotational temperature (Trot), the excitation temperature (Texc), the ionization temperature (Tion) and the electron number density (ne) were determined. The current–voltage characteristic of the source was studied as well. At optimized conditions the discharge operates in the normal region of the current–voltage characteristic. Rotational and excitation temperatures determined with the use of OH band and Fe I lines as thermometric species were of the or…
Atomic spectroscopy: a review
2010
Atomic Absorption Spectrometry 4653 Flame Atomic Absorption Spectrometry 4653 Electrothermal Atomic Absorption Spectrometry 4654 Volatile Species Generation Atomic Absorption Spectrometry 4654 Direct Solids Atomic Absorption Spectrometry 4655 Continuum Source Atomic Absorption Spectrometry 4655 Atomic Fluorescence Spectrometry 4655 Atomic Emission Spectrometry 4656 DC Arc and Low-Power RF Radiation Sources 4656 Inductively Coupled Plasmas 4656 Microwave Induced Plasmas 4658 Microplasmas 4658 Laser Induced Breakdown Spectroscopy 4658 Glow Discharge Optical Emission and Mass Spectrometry 4660 Fundamental Studies 4660 Methodological Studies and Applications of GD-OES and GDMS 4661 New GD Sourc…
Plasma Etching and Integration with Nanoprocessing
2009
This chapter introduces plasma etching—an extensive and perhaps the most widely used micro- and nanoprocessing method both in industry and in research and development laboratories worldwide. The emphasis is on the practical methods in plasma etching and reactive ion etching when used for submicron and nanoscale device fabrication. The principles of plasma etching and reactive ion etching equipment for sample fabrication will be introduced.