Search results for "Doppler"
showing 10 items of 637 documents
Very narrow-bandwidth tunable infrared difference frequency generation with injection-locked dye lasers
1989
Two flashlamp pumped dye lasers of very high spectral quality are mixed in a LiIO3 crystal to generate a tunable infrared beam through the difference frequency mixing. Thanks to the injection-locking process of the pulsed dye lasers leading to a linewidth of 6 MHz with peak powers of about 10 kW, we obtain an IR beam tunable from 3.5 to 5.9 μm with a peak power of 40 W and a linewidth of 9 MHz. As an application we present a spectrum of N2O obtained by differential absorption near 1880 cm−1. The lines of thisQ-branch are Doppler limited at the working pressure (102 Pa).
Analysis of the level-crossing rate and average duration of fades of WSSUS channels
2017
Studies of the level-crossing rate (LCR) and the average duration of fades (ADF) are so far only devoted to stochastic processes being a function of one independent variable, which is usually time or in some few cases frequency. In this paper, we study the LCR (ADF) of wide-sense stationary uncorrelated scattering (WSSUS) processes in the time-frequency domain. A closed-form solution will be derived for the so-called time-frequency LCR (ADF) of the absolute value of the time-variant transfer function (TVTF) of WSSUS processes. It is shown that the LCR (ADF) is circularly symmetric in the normalized time-frequency domain. The derived time-frequency LCR contains the time LCR and frequency LCR…
Early Vascular Aging in Normotensive Patients With Systemic Lupus Erythematosus
2015
Connective tissue diseases, like systemic lupus erythematosus (SLE), are associated with early and accelerated atherosclerosis. Recently, the concept of “early vascular aging” (EVA) has been more widely accepted. Aortic stiffness is one of the important markers of EVA. We evaluated EVA and subclinical atherosclerosis, by measuring aortic pulse wave velocity (aPWV) and carotid intima–media thickness (cIMT), in 50 normotensive patients with SLE (mean age: 39 ± 12 years). We compared these participants with 50 age- and sex-matched patients with essential hypertension (EH) and 20 healthy controls. Each participant underwent 24-hour ambulatory blood pressure monitoring (ABPM), aPWV, and cIMT me…
Collisional effects on spectral line shape from the Doppler to the collisional regime: A rigorous test of a unified model
2000
International audience; The paper presents high resolution Raman investigations of the Q(1) line of H-2 in Ar mixture from low density (Doppler regime) to high density (collisional regime) analyzed with a unique line shape profile. Measurements are performed by stimulated Raman gain spectroscopy between 300 and 1000 K in a wide density range (from 0.2 to 11 amagat). All the observed spectral features are accurately described by a unified model recently proposed by two of the authors. This model accounts for a velocity-memory process, not restricted to the usual hard and soft limits. It also includes correlation between velocity- and phase-changing collisions. An exhaustive analysis of vario…
Measurement of the transverse Doppler shift using a stored relativistic7Li+ ion beam
1992
We have performed for the first time precision spectroscopy on a coasting fast7Li+ ion beam in a storage ring. The ion beam moving with 6.4% speed of light was first electron cooled and then merged with two counterpropagating laser beams acting on two different hyperfine transitions sharing a common upper level (λ-system). One laser was frequency locked to thea 3 127J2 hfs frequency component established as a secondary frequency standard at 514 nm. The second laser was tuned over theλ-resonance, which was recorded relative to127J2 hfs components. This experiment is sensitive to the time dilation in fast moving frames and will lead to new limits for the verification of special relatively. Th…
External polytetrafluoroethylene reinforcement of varicose autologous vein grafts in peripheral bypass surgery produces durable bypass function
2017
Abstract Objective Use of autologous veins as peripheral bypass graft may become critical in the presence of significant varicose degeneration of the harvested vein. External support of such dilated veins with standard polytetrafluoroethylene (PTFE) prostheses was recommended as an option to use these veins for peripheral bypass. A single-center experience with this technique regarding long-term graft function, secondary reinterventions, and potential graft degeneration is presented. Methods Between January 1995 and January 2006, there were 54 patients with varicose veins who underwent 57 consecutive infrainguinal vein bypass operations with PTFE reinforcement in 57 limbs. Indications for s…
Diagnostic accuracy of current sonographic criteria for the detection of outflow abnormalities in the internal jugular veins
2012
Objectives: This study was aimed at evaluation of the diagnostic value of Doppler sonography for the assessment of abnormalities in the internal jugular veins (IJVs). Method: One hundred and sixteen IJVs were assessed in 58 patients with associated multiple sclerosis. Findings of Doppler sonography were compared with results of the reference test: catheter venography. Results: At least one positive extracranial sonographic criterion suggesting venous abnormality was found in 92.2% of the assessed veins. Yet, sensitivity, specificity, positive and negative predictive values of sonography were low: 93.4%, 12.0%, 79.4% and 33.3% for at least one positive criterion, and for at least two positiv…
Sympathetic Vasomotor Response of the Radial Artery in Patients With Diabetic Foot Syndrome
2003
OBJECTIVE—Neurophysiological assessment of the peripheral autonomic system is characterized by various limitations. An alternative approach to laser Doppler and venous plethymography is the assessment of the sympathetic vasomotor response of the radial artery obtained by continuous wave Doppler sonography. Nomogram data have been established and demonstrate the temporary disappearance of diastolic flow after coughing or deep inspiration. RESEARCH DESIGN AND METHODS—We assessed the sympathetic vasomotor response in 25 patients (mean age 64 years, range 43–76) with diabetic foot syndrome. The Doppler data were correlated with nerve conduction studies of the median and peroneal nerve, the exte…
A Trajectory-Driven SIMO mm-Wave Channel Model for a Moving Point Scatterer
2021
In this paper, we propose a trajectory-based three-dimensional (3D) non-stationary channel model for a millimeter wave (mm-Wave) single-input multiple-output (SIMO) system. The proposed channel model is designed to capture the mobility of a moving point scatterer in an indoor environment. We derive the expression of the time-variant (TV) channel transfer function (CTF). We study the TV Doppler characteristics of the channel, such as the TV Doppler power spectrum and the TV mean Doppler shift. To validate the proposed channel model, we performed a measurement campaign in an indoor environment using a software defined radar operating at 24 GHz. As a moving object, we consider a single swingin…
Regurgitant flow in apparently normal valve prostheses: improved detection and semiquantitative analysis by transesophageal two-dimensional color-cod…
1990
In 128 patients with apparently normally functioning prosthetic valves ( n = 136) in the aortic position ( n = 79) and the mitral position ( n = 57), the prevalence of transprosthetic regurgitant flow was studied by use of transthoracic and transesophageal two-dimensional color-coded Doppler echocardiography. With the transthoracic approach, regurgitant flow was detected in early systole or diastole for 28% of the mitral prostheses and for 29% of the aortic prostheses. With transesophageal color-coded Doppler echocardiography, regurgitant jets were visualized for 95% of the mitral prostheses and for 44% of the aortic prostheses. In 40% of the Bjork-Shiley prostheses and 88% of the St. Jude …