Search results for "Dosimeter"

showing 10 items of 96 documents

NMR relaxometry measurements of Fricke gel dosimeters exposed to neutrons

2014

Fricke infused gel matrices offer several features making them suitable for dosimetric applications; among the set here are tissue equivalence, low cost and ease of preparation. Their nuclear magnetic resonance (NMR) relaxation properties can be used as a radiation detector for the dosimetry of beams used in cancer therapy. In recent years neutron capture therapy has been resumed for the treatment of various types of cancer and it requires three-dimensional mapping of the neutron fields. In this work, we investigated this particular application through NMR relaxometry and MR imaging of Fricke gels exposed to neutrons. We analyzed both the R1 and R2 relaxation rates, which relate to the long…

Nuclear magnetic resonance relaxometryRelaxometryRadiationDosimeterChemistryPhysics::Medical PhysicsRelaxation (NMR)FluenceSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Neutron captureGel dosimeterNuclear magnetic resonanceMagnetic resonance imagingNeutron fluxDosimetryFricke methodNeutronNeutron beam
researchProduct

Improvement of ESR dosimetry for thermal neutron beams through the addition of gadolinium.

2007

In this paper, the addition of gadolinium is proposed as a useful tool to enhance the electron spin resonance (ESR) sensitivity of organic compounds to thermal neutrons. The target of this work is the detection, through the ESR technique, of the thermal neutron fluence in a mixed field of photons and neutrons. Gadolinium was chosen because it has a very high capture cross section to thermal neutrons; its nuclear reaction with thermal neutrons induces complex inner shell transitions that generate, besides other particles, Auger electrons, which in turn release their energy in the neighborhood (only several nanometers) of the place of reaction. Gadolinium was added to two organic molecules: a…

Nuclear reactionMaterials scienceHot TemperaturePhysics::Instrumentation and DetectorsGadoliniumPhysics::Medical PhysicsAnalytical chemistrychemistry.chemical_elementGadoliniumRadiation DosageFluenceSensitivity and Specificitylaw.inventionsymbols.namesakeNuclear magnetic resonancelawRadiology Nuclear Medicine and imagingNeutronElectron paramagnetic resonanceRadiometryNeutronsDosimeterRadiological and Ultrasound TechnologyAuger effectElectron Spin Resonance SpectroscopyReproducibility of ResultsNeutron temperatureESR dosimetry thermal neutron gadoliniumchemistrysymbolsCondensed Matter::Strongly Correlated ElectronsPhysics in medicine and biology
researchProduct

Power saturation of ESR signal in ammonium tartrate exposed to 60Co gamma-ray photons, electrons and protons.

2006

Abstract Marrale, M., Brai, M., Triolo, A., Bartolotta, A. and D'Oca, M. C. Power Saturation of ESR Signal in Ammonium Tartrate Exposed to 60Co γ-Ray Photons, Electrons and Protons. Radiat. Res. 166, 802–809 (2006). In this paper we present an investigation of the electron spin resonance (ESR) line shape of ammonium tartrate (AT) dosimeters exposed to radiation with different linear energy transfer (LET). We exposed our dosimeters to γ-ray photons (60Co), 7 MeV and 14 MeV initial energy electrons, and 19.3 MeV initial energy protons. The differences in the power saturation behavior of ESR spectra of AT irradiated with photons, electrons and protons could be correlated to the effective LET o…

PhotonBiophysicsLinear energy transferElectronsElectronRadiationRadiation DosageSensitivity and Specificitylaw.inventionlawRadiology Nuclear Medicine and imagingLinear Energy TransferIrradiationCobalt RadioisotopesElectron paramagnetic resonanceRadiometrySaturation (magnetic)TartratesPhotonsRadiationDosimeterChemistryElectron Spin Resonance SpectroscopyReproducibility of ResultsDose-Response Relationship RadiationAmmonium Tartrate 60Co -Ray Photons Electrons and Protons.Gamma RaysAtomic physicsProtonsAlgorithmsRadiation research
researchProduct

Sensitivity of alanine dosimeters with gadolinium exposed to 6 MV photons at clinical doses.

2011

In this study we analyzed the ESR signal of alanine dosimeters with gadolinium exposed to 6 MV linear accelerator photons. We observed that the addition of gadolinium brings about an improvement in the sensitivity to photons because of its high atomic number. The experimental data indicated that the addition of gadolinium increases the sensitivity of the alanine to 6 MV photons. This enhancement was better observed at high gadolinium concentrations for which the tissue equivalence is heavily reduced. However, information about the irradiation setup and of the radiation beam features allows one to correct for this difference. Monte Carlo simulations were carried out to obtain information on …

PhotonESR dosimetryGadoliniumMonte Carlo methodAccelerationBiophysicschemistry.chemical_elementGadoliniumLinear particle acceleratorRadiology Nuclear Medicine and imagingIrradiationRadiometryMonte Carlo simulationAlaninePhotonsRadiationDosimeterAlanineChemistryX-RaysRadiochemistryElectron Spin Resonance SpectroscopyDose-Response Relationship RadiationSettore FIS/07 - Fisica Applicata(Beni Culturali Ambientali Biol.e Medicin)Alanine dosimeters gadoliniumLinear ModelsSensitivity (electronics)Monte Carlo MethodRadiation research
researchProduct

Study of reliability of TLDs for the photon dose mapping in reactor neutron fields for BNCT

2008

Abstract Photon dose measurements in radiation fields having the proper characteristics for boron neutron capture therapy (BNCT) present several troubles. The thermal neutron flux is very high and produces a significant contribution to the response of most dosimeters. The consistency of photon dose measurements with CaF 2 :Tm and LiF:Mg, Ti thermoluminescent dosimeters has been studied. A method is described for obtaining the gamma dose with TLD-700 and some results are presented to test its reliability.

PhysicsNeutron captureRadiationDosimeterRadiochemistryGamma rayDose profileNeutronThermoluminescent dosimeterRadiationInstrumentationNeutron temperatureRadiation Measurements
researchProduct

Anomalous behavior of LiF:Mg,Cu,P (TLD100H) irradiated with electron beams

2006

Abstract Thermoluminescent dosimeters of LiF:Mg,Cu,P (TLD100H) were exposed to 60Co γ -ray, protons, high energy electrons and the glow curves were analyzed. We observed an unusual behavior of the TL response of dosimeters to 7 and 14 MeV electron beam. In fact the relative amplitude between two of the five peaks (2° and 3° peaks) assumes values smaller than the unity for doses up to 5 Gy and values greater than the unity for doses equal to or greater than 10 Gy. A possible explanation of this behavior is given adopting a model of the formation of the peaks 2° and 3° and examining the different ways of energy release in matter for each beam. To perform this analysis we deconvoluted the glow…

PhysicsNuclear and High Energy PhysicsDosimeterbusiness.industryTrappingElectronKinetic energyThermoluminescenceOpticsLETCathode rayTLD100HIrradiationAtomic physicsbusinessInstrumentationGOKBeam (structure)thermoluminescenceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Glow curve analysis of TLD-100H irradiated with radiation of different LET: Comparison between two theoretical method

2006

In the present paper we show the result of study on the thermoluminescent signal of LiF:Mg,Cu,P (TLD-100H) after irradiation with beams of different LET (photons, electrons and protons). Through the analysis of the glow curve it is possible to obtain information on the LET of the radiation beam. To perform this analysis we have deconvoluted the glow curves adopting general order kinetic equation for the description of the peak shape. In addition a numerical simulation has been performed to find a connection among the physical parameters of the model (OTOR) and the parameters of the empirical expression used in the analysis of the experimental data (GOK). The methodology indicate that the ki…

PhysicsNuclear and High Energy PhysicsPhotonComputer simulationTLD-100HElectronRadiationKinetic energyThermoluminescenceLETIrradiationThermoluminescent dosimeterAtomic physicsInstrumentationGOKthermoluminescenceNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Production and characterization of a custom-made 228Th source with reduced neutron source strength for the Borexino experiment

2012

A custom-made 228Th source of several MBq activity was produced for the Borexino experiment for studying the external background of the detector. The aim was to reduce the unwanted neutron emission produced via (alpha,n) reactions in ceramics used typically for commercial 228Th sources. For this purpose a ThCl4 solution was converted chemically into ThO2 and embedded into a gold foil. The paper describes the production and the characterization of the custom-made source by means of gamma-activity, dose rate and neutron source strength measurements. From gamma-spectroscopic measurements it was deduced that the activity transfer from the initial solution to the final source was >91% (at 68%…

PhysicsNuclear and High Energy PhysicsPhysics - Instrumentation and DetectorsDosimeterIsotope530 PhysicsNeutron emission3105 InstrumentationRadiochemistryFOS: Physical sciencesThoriumchemistry.chemical_elementInstrumentation and Detectors (physics.ins-det)10192 Physics InstituteNuclear physicschemistryMeasuring instrumentNeutron source3106 Nuclear and High Energy PhysicsInstrumentationBorexinoIsotopes of thoriumNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
researchProduct

Monte Carlo and experimental derivation of TG43 dosimetric parameters for CSM-type Cs-137 sources

2004

In this study, complete dosimetric datasets for the CSM2 and CSM3 Cs-137 sources were obtained using the Monte Carlo GEANT4 code. The application of this calculation method was experimentally validated with thermoluminescent dosimetry (TLD). Functions and parameters following the TG43 formalism are presented: the dose rate constant, the radial dose functional, and the anisotropy function. In addition, to aid the quality control process on treatment planning systems, a two-dimensional (2D) rectangular dose rate table (the traditional along-away table), coherent with the TG43 dose calculation formalism, is given. The data given in this study complement existing information for both sources on…

PhysicsPhotonmedia_common.quotation_subjectPhysics::Medical PhysicsMonte Carlo methodGeneral MedicineAsymmetryThermoluminescent DosimetryDosimetryStatistical physicsThermoluminescent dosimeterAnisotropyImage resolutionmedia_commonMedical Physics
researchProduct

Improvement of the LET sensitivity in ESR dosimetry for -photons and thermal neutrons through gadolinium addition

2007

Abstract We investigated the ESR response of new materials, alanine and ammonium tartrate to which gadolinium was added. The addition of gadolinium enhances sensitivity for Co 60 γ -photons because of its high atomic number ( Z = 64 ) and an enhancement of sensitivity for thermal neutrons because of its high thermal neutron cross section and high linear energy transfer (LET) secondary particles produced after the reaction with neutrons. In particular, in this paper we analyzed the microwave power saturation properties of dosimeters of alanine and ammonium tartrate with or without gadolinium exposed to different LET beams. The power saturation trends of dosimeters exposed to photons and to t…

PhysicsRadiationDosimeterammonium tartrateGadoliniumPhysics::Medical PhysicsRadiochemistrychemistry.chemical_elementLinear energy transferRadiationNeutron temperatureGd2O3-ammonium tartratechemistry.chemical_compoundGd2O3-alaninechemistryLETDosimetryCondensed Matter::Strongly Correlated ElectronsAmmoniumNeutronalanineInstrumentationESRRadiation Measurements
researchProduct