Search results for "Dosimetry"
showing 10 items of 297 documents
Model-Based Dose Calculation Algorithms for Brachytherapy Dosimetry
2019
The purpose of this study was to review the limitations of dose calculation formalisms for photon-emitting brachytherapy sources based on the American Association of Physicists in Medicine (AAPM) Task Group No. 43 (TG-43) report and to provide recommendations to transition to model-based dose calculation algorithms. Additionally, an overview of these algorithms and approaches is presented. The influence of tissue and seed/applicator heterogeneities on brachytherapy dose distributions for breast, gynecologic, head and neck, rectum, and prostate cancers as well as eye plaques and electronic brachytherapy treatments were investigated by comparing dose calculations based on the TG-43 formalism …
External photon radiation treatment for prostate cancer: Uncomplicated and cancer-free control probability assessment of 36 plans
2019
[Purpose] To perform a systematic and thorough assessment, using the Uncomplicated and Cancer-Free Control Probability (UCFCP) function, of a broad range of photon prostate cancer RT treatments, on the same scenario (a unique pelvic CT set). UCFCP considers, together with the probabilities of local tumour control (TCP) and deterministic (late) sequelae (NTCP), the second primary cancer risk (SPCR) due to photon and neutron peripheral doses.
Treatment of hyperthyroidism with radioiodine targeted activity: A comparison between two dosimetric methods.
2016
Radioiodine therapy is an effective and safe treatment of hyperthyroidism due to Graves' disease, toxic adenoma, toxic multinodular goiter. We compared the outcomes of a traditional calculation method based on an analytical fit of the uptake curve and subsequent dose calculation with the MIRD approach, and an alternative computation approach based on a formulation implemented in a public-access website, searching for the best timing of radioiodine uptake measurements in pre-therapeutic dosimetry. We report about sixty-nine hyperthyroid patients that were treated after performing a pre-therapeutic dosimetry calculated by fitting a six-point uptake curve (3-168h). In order to evaluate the res…
Dose Estimation for the European Epidemiological Study on Pediatric Computed Tomography (EPI-CT).
2021
International audience; Within the European Epidemiological Study to Quantify Risks for Paediatric Computerized Tomography (EPI-CT study), a cohort was assembled comprising nearly one million children, adolescents and young adults who received over 1.4 million computed tomography (CT) examinations before 22 years of age in nine European countries from the late 1970s to 2014. Here we describe the methods used for, and the results of, organ dose estimations from CT scanning for the EPI-CT cohort members. Data on CT machine settings were obtained from national surveys, questionnaire data, and the Digital Imaging and Communications in Medicine (DICOM) headers of 437,249 individual CT scans. Exp…
Improving pediatric radiation dose management using Agfa digital radiography DICOM header information
2007
Dose reduction in pediatric explorations is especially important because of children radiation sensitivity. According to this, with the aim of saving radiation exposure in future clinical practice, we have developed a technique to control delivered dose in pediatric radiographic exams. To that, a computer science program has been developed to calculate entrance skin dose (ESD) provided by AGFA radiology digital system, using the "lgM" parameter exported from Dicom files. ESD values are compared with dose limits established in regulations to detect if children are being exposed to excessive amounts of radiation during their explorations.
Multiparametric MRI and post implant CT-based dosimetry after prostate brachytherapy with iodine seeds: The higher the dose to the dominant index les…
2015
Abstract Purpose To determine whether post-implant MRI-based dosimetry of the Dominant Intra-prostatic Lesion (DIL) could best predict the occurrence of PSA bounce after prostate brachytherapy. Methods and materials We selected 66 patients with a low risk prostate cancer treated with 125 I prostate brachytherapy as monotherapy. Post-implant dosimetry based on day 30 CT-scan and multiparametric MRI co-registration was generated: planned D 90, D 95, V 100, V 150 values were calculated for each DIL. Bounce was defined as a PSA elevation ⩾0.2ng/mL from the previous baseline value followed by a decrease to or below the prior nadir with no additional treatment. Results After a median follow-up of…
Thermoluminescence Response of AlN+Y2O3 Ceramics to Sunlight and X-Ray Irradiation
2021
The present research has been sponsored by the Latvian Council of Science, Grant No. lzp-2018/1-0361. The Institute of Solid State Physics, University of Latvia as the Centre of Excellence has received funding from the European Union’s Hori-zon 2020 Framework Programme H2020-WIDESPREAD-01-2016-2017-Teaming-Phase2 under grant agreement No.73950, project CAMART.2
Thermostimulated luminescence of plasma electrolytic oxidation coatings on 6082 aluminium surface
2019
Financial support provided by Scientific Research Project for Students and Young Researchers Nr. SJZ/2016/12 realized at the Institute of Solid State Physics, University of Latvia is greatly acknowledged. Authors are grateful to R. Ignatans for measurements and analysis of XRD spectra and ElGoo Tech ltd. for providing PEO equipment.
Usability of Cr-Doped Alumina in Dosimetry
2019
Dosimetry is a widespread material science field dealing with detection and quantification of ionizing radiation using electronic processes in materials. One of the main aspects that determines the performance of dosimeters is the type of defects the material contains. Crystalline lattice imperfections are formed around impurity ions, which may have a smaller or larger size, or different oxidation states compared to host ions. In this study, we show what effects Cr impurities have on the luminescent properties of alumina. Porous Al 2 O 3 : Cr microceramics synthesized using the sol-gel method showed a higher thermoluminescence response than a single crystal ruby. We have found that Cr 2 O 3…
Novel GTA-PVA Fricke gels for three-dimensional dose mapping in radiotherapy
2017
Abstract One of the most recent and promising developments in radiotherapy dosimetry was the introduction of 3D radiation-sensitive gels. These gels present tissue equivalent composition and density, so they also serve as phantoms, and their response is largely independent of radiation quality and dose rate. Some gels are infused with ferrous sulfate and rely on the radiation-induced oxidation of ferrous ions to ferric ions (Fricke-gels). These formulations suffer from spontaneous-oxidation and diffusion of ferric ions after irradiation; chelating agents such as xylenol-orange significantly reduces the latter. Other gel types consist of dispersed monomers, and rely on radiation-induced cros…