Search results for "Drug Contamination"
showing 10 items of 20 documents
A green method for the determination of cocaine in illicit samples
2013
Abstract Direct determination of cocaine in untreated seized samples has been made based on diffuse reflectance measurements of the near infrared (NIR) radiation through samples contained inside standard glass vials. The method used a series of previously analyzed samples, by the reference gas chromatography method, to build a partial least squares calibration model which was validated using an independent set of samples. The use of a general model for samples containing from 11.38% till 86.44% (w/w) cocaine was based on the use of spectral ranges from 12500.7 to 10128.6, 9339.8 to 6967.7 and 5388.3 to 4597.6 cm−1 with previous first derivative and vector normalization data pre-processing a…
In-use physicochemical and microbiological stability of biological parenteral products
2015
Pharmaceutical scientists in the biotechnology industry have traditionally focused on achieving acceptable shelf lives of drug products in their original, unopened product unit configuration (e.g., two years stored at 2–8 °C). However, it is now clear that stability considerations extend beyond
Toxicities by herbal medicines with emphasis to traditional Chinese medicine.
2011
It is estimated that three quarters of the world population rely on herbal and traditional medicine as a basis for primary health care. Therefore, it is one of the most important and challenging tasks for scientists working in drug research to investigate the efficacy of herbal medicine, to dissect favorable from adverse effects, to identify active principles in medicinal plants and to ban poisonous plants or contaminations from herbal mixtures. In the present review, some problems are critically discussed. Botanical misidentification or mislabeling of plant material can play a role for toxic reactions in humans. Some plant descriptions in traditional herbal medicine (e.g. traditional Chine…
Insights in ChAdOx1 nCoV-19 vaccine-induced immune thrombotic thrombocytopenia
2021
Abstract SARS-CoV-2 vaccine ChAdOx1 nCoV-19 (AstraZeneca) causes a thromboembolic complication termed vaccine-induced immune thrombotic thrombocytopenia (VITT). Using biophysical techniques, mouse models, and analysis of VITT patient samples, we identified determinants of this vaccine-induced adverse reaction. Super-resolution microscopy visualized vaccine components forming antigenic complexes with platelet factor 4 (PF4) on platelet surfaces to which anti-PF4 antibodies obtained from VITT patients bound. PF4/vaccine complex formation was charge-driven and increased by addition of DNA. Proteomics identified substantial amounts of virus production-derived T-REx HEK293 proteins in the ethyle…
Particulate Matter Contamination of Intravenous Antibiotics Aggravates Loss of Functional Capillary Density in Postischemic Striated Muscle
2002
Through the increased use of less expensive and counterfeit medicines, the contamination of parenteral fluids and drugs by particulate matter poses an increasing health hazard worldwide. However, the mechanism of action of such contamination has never been conclusively demonstrated. We have systemically injected the particles contained in three different 1-g preparations of the antibiotic cefotaxime into hamsters and visualized the functional capillary density in striated skin muscle, using intravital fluorescence microscopy. Injection of particles from either of the three preparations did not affect capillary perfusion in normal muscle (n = 3 hamsters, each). However, injection of particle…
Determination of acetazolamide in human urine samples by reversed-phase high-performance liquid chromatography in the presence of xanthines.
1992
A simple, rapid and selective high-performance liquid chromatographic assay for the determination of acetazolamide in urine samples is described. After extraction with ethyl acetate, the drug is chromatographed on an HP-Hypersil ODS-C18 column with a mobile phase of acetonitrile-phosphate buffer (pH 3) and ultraviolet detection at 275 nm. The efficiency of the extraction, the linearity and the reproducibility of the method permit the evaluation of acetazolamide urinary excretion a long time after its administration.
Near Infrared Spectroscopy Detection and Quantification of Herbal Medicines Adulterated with Sibutramine.
2015
There is an increasing demand for herbal medicines in weight loss treatment. Some synthetic chemicals, such as sibutramine (SB), have been detected as adulterants in herbal formulations. In this study, two strategies using near infrared (NIR) spectroscopy have been developed to evaluate potential adulteration of herbal medicines with SB: a qualitative screening approach and a quantitative methodology based on multivariate calibration. Samples were composed by products commercialized as herbal medicines, as well as by laboratory adulterated samples. Spectra were obtained in the range of 14,000-4000 per cm. Using PLS-DA, a correct classification of 100% was achieved for the external validatio…
Efficacy of different concentrations of sodium hypochlorite and chlorhexidine in disinfection of contaminated Resilon cones.
2011
Objectives: The aim of this study was to evaluate the effectiveness of different concentrations of Chlorhexidine (CHX) and sodium hypochlorite (NaOCl) in disinfecting contaminated Resilon cones within one minute. Study design: Fifty Resilon cones were divided into seven experimental groups and three control groups of 5 cones each. The cones of experimental groups were contaminated with Entrococcus faecalis and subsequently disinfected with different concentrations of NaOCl or CHX. The cones were then transferred into glass tubes containing thioglycollate media and incubated for 7 days. The tubes were examined for turbidity every 24 hours, and if bacterial growth occurred, samples were plate…
Influence of artificial blood contamination of the analysis of cerebrospinal fluid
1981
The influence of artificial blood contamination on the quantitative values obtained in the routine examination of the CSF was investigated. On the basis of dilution series from CSF and blood, the correlation between the number of added erythrocytes and the results of leukocyte counts, protein, glucose and IgG estimation was studied. In addition, the influence of the time between CSF sampling and investigation on erythrocytes and leukocytes, IgG, glucose, pH value and ammonia content in CSF contaminated with blood was investigated. The following data relevant to routine examinations resulted: there are linear correlations between the number of erythrocytes artificially added to the CSF and t…
Media-fill simulation tests in manual and robotic aseptic preparation of injection solutions in syringes
2014
Objective The purpose of this study was to evaluate the contamination rate of media-fill products either prepared automated with a robotic system (APOTECAchemo™) or prepared manually at cytotoxic workbenches in the same cleanroom environment and by experienced operators. Media fills were completed by microbiological environmental control in the critical zones and used to validate the cleaning and disinfection procedures of the robotic system. Methods The aseptic preparation of patient individual ready-to-use injection solutions was simulated by using double concentrated tryptic soy broth as growth medium, water for injection and plastic syringes as primary packaging materials. Media fills w…