Search results for "ELASTOMERS"
showing 9 items of 29 documents
Synthesis and characterization of redox-sensitive polyurethanes based on L-glutathione oxidized and poly(ether ester) triblock copolymers
2021
Abstract Segmented polyurethanes, based on PCL-PEG-PCL copolymers, 1,4-diisocyanatobutane and l -glutathione oxidized, used as chain extender, were synthetized. Three different reactions conditions were investigated using three different copolymers having ɛ-CL/polyethylene glycol molar ratios equal to 12, 24 and 36 and three different reaction conditions. As investigated by size exclusion chromatography analyses and quantification of l -glutathione, the polymerization and the extension phase's efficiency depended on the ɛ-CL/PEG ratio and the extension phase's operating temperature. Three selected polyurethanes were characterized by spectroscopic, differential scanning calorimetry (DSC) and…
Comparative in vitro study of the accuracy of impression techniques for dental implants: Direct technique with an elastomeric impression material ver…
2019
Background The aim of this study was to compare a conventional technique (elastomeric impression material - EIM) and a digital technique (scanner digital model – SDM) on a six-analog master model (MM) to determine which was the most exact. Material and Methods Twenty impressions were taken of a master model (EIM) and twenty scanned impressions (SDM) (True Definition). A coordinate measuring machine (CMM) was used to measure the distances between adjacent analogues (1-2, 2-3, 3-4, 4-5, 5-6), intermittently positioned analogues (1-4, 3-6) and the most distal (1-6). Reference values were established from the master model, which were compared with the two impression techniques. The significance…
Resistance to disinfection of a polymicrobial association contaminating the surface of elastomeric dental impressions.
2009
The aim of this study was to evaluate the ability to resist disinfection of a polymicrobial association contaminating the surface of dental impressions obtained with two different elastomers: a polyether (Impregum) and an addition-polymerized silicone (Elite). Impressions were contaminated with a mixture of three biofilm-forming microorganisms (Staphylococcus aureus, Pseudomonas aeruginosa and Candida albicans) and disinfected immediately after contamination, or after microbial layers were allowed to develop during a six-hour storage. Two commercial disinfectants were tested: MD 520 containing 0.5% glutaraldehyde and Sterigum Powder without glutaraldehyde. Residual contamination was recover…
Use of new hydroxytelechelic cis-1,4-polyisoprene (HTPI) in the synthesis of polyurethanes (PUs): Influence of isocyanate and chain extender naturean…
2006
AbstractNew segmented polyurethanes (thermoplastic-elastomers) based on previously described hydroxytelechelic cis-1,4-polyisoprene (HTPI), miscellaneous isocyanates and chain extenders at various equivalent ratios were prepared by the classical one-shot method. The influence of the nature of isocyanate and chain extender, as well as their equivalent ratios, on the mechanical and thermal materials behavior was investigated. Thus, a comparative assessment of material properties was performed. Microphase separation of hard and soft segments was observed by DMTA, DSC and AFM. Moreover, according to Thermogravimetric Analysis (TGA), linear relationships depending on the isocyanate and chain ext…
A free plate model can predict guided modes propagating in tubular bone-mimicking phantoms
2014
The goal of this work was to show that a non-absorbing free plate model can predict with a reasonable accuracy guided modes measured in bone-mimicking phantoms that have circular cross-section. Experiments were carried out on uncoated and coated phantoms using a clinical axial transmission setup. Adjustment of the plate model to the experimental data yielded estimates for the waveguide characteristics (thickness, bulk wave velocities). Fair agreement was achieved over a frequency range of 0.4 to 1.6 MHz. A lower accuracy observed for the thinnest bone-mimicking phantoms was caused by limitations in the wave number measurements rather than by the model itself.
Absorption of oxybutynin from vaginal inserts: drug blood levels and the response of the rabbit bladder.
2000
Abstract Objectives. Oxybutynin has been used for treatment of urge urinary incontinence for more than 20 years. However, one of the major problems with its use is uncomfortable anticholinergic side effects that can lead to discontinuation of treatment. Alternative forms of drug administration may reduce side effects and thus improve patient compliance. Methods. A cylinder-shaped, curved silicone elastomer insert containing oxybutynin was anchored in the vagina of female rabbits. The inserts were designed to release oxybutynin at rates of 0.5, 1.0, and 5.0 mg/day, respectively. Blood drug and metabolite levels were monitored for 1 to 7 days and cystometry was carried out after 7 days of tre…
Physicochemical Surface Properties of Various Intraocular Lenses
2001
<i>Purpose:</i> It is of major interest to understand how intraocular lens (IOL) surfaces interact with aqueous humor or tissues after implantation. Important parameters to describe the physicochemical surface properties are the contact angle and critical surface tension. Therefore, we performed measurements of the contact angle and critical surface tension of several commercially available IOLs. <i>Setting:</i> Department of Ophthalmology, Johannes Gutenberg University, Mainz, University Eye Hospital, Tübingen, and Max Planck Institute for Polymer Research, Mainz, Germany. <i>Methods:</i> A total of 17 commercially available standard quality IOL types (6…
Changes in higher-order aberrations after implantation of a foldable iris-claw lens in myopic phakic eyes
2006
Purpose To evaluate the change in higher-order aberrations (HOAs) after implantation of a foldable iris-claw phakic intraocular lens (pIOL) in myopic eyes. Setting Department of Ophthalmology, Johannes Gutenberg-University, Mainz, Germany. Methods This prospective nonrandomized comparative self-controlled trial included 41 eyes that had implantation of a foldable iris-claw pIOL between July 2003 and November 2004. All patient data for HOAs (Zernike coefficient) were measured and calculated using the same pupil size preoperatively and postoperatively, and the root-mean-square (RMS) wavefront error was calculated. Examinations were performed preoperatively as well as 1 week and 3, 6, and 12 m…
The effect of immersion disinfection procedures on dimensional stability of two elastomeric impression materials
2008
The aim of this study was to determine the effect of immersion disinfection procedures on the dimensional stability of two elastomeric impression materials. Impressions of a stainless steel die were made with polyether (PE) and with additionpolymerized silicone rubber (PVS). The test specimens underwent disinfection treatment by immersion in two commercially available solutions containing quaternary ammonium compounds (Sterigum Powder, SP) and glutaraldehyde plus an amino derivative (MD520, MD), respectively. The impressions were measured at 4 different time points: before any disinfection treatment (T0); after the first disinfection (T1); 6 hours after the first disinfection (T2); after th…