Search results for "ELECTRONICS"
showing 10 items of 4340 documents
MgO Magnetic Tunnel Junction Electrical Current Sensor With Integrated Ru Thermal Sensor
2013
Full Wheatstone bridge electrical current sensor incorporating 114 MgO-based magnetic tunnel junction elements (3 × 30 μm2) connected in series was produced for improved electrical robustness. To that end, magnetic tunnel junctions with R × A ~7 KΩ μm2 tunneling magnetoresistance of 200%, were produced. The sensor was designed with an integrated Ru thin film resistive thermal detector (RTD) for temperature drift monitoring and compensation. In order to achieve a full bridge signal, a U-shaped copper trace was placed under a printed circuit board (PCB) specifically designed for this type of device. The resulting device exhibit sensitivities of 63.9 V/Oe/A in a 75 Oe linear range biased with …
Note: Direct sensor resistance-to-frequency conversion with generalized impedance converter.
2010
In this note a squared output signal is generated from an astable circuit. Its frequency has a linear dependence on the resistance value of a resistive temperature sensor. The main circuit to obtain this direct relationship is the generalized impedance converter configured as a capacitor controlled by a sensor resistance. The proposed measurement method allows a direct analog-to-digital interface of information involved in resistive sensors. The converter finds applications in portable low voltage and low power design of instrumentation electronic systems.
Monolayer Structure of Arachidic Acid on Graphite
2010
The self-assembly of arachidic acid (C(19)H(39)COOH) at the liquid solid interface between 1-phenyloctane (C(6)H(5)(CH(2))(7)CH(3)) and highly oriented pyrolytic graphite (HOPG) is studied by scanning tunneling microscopy (STM) to identify the structure of the monomolecular film. We observe the formation of highly ordered domains with molecules oriented in three different orientations compatible with the symmetry of the HOPG substrate, a spontaneous enantiomeric separation of the pro-chiral molecules, and reveal structural details with submolecular resolution. To determine the surface unit cell with an intrinsic calibration to the substrate atomic structure, the intermolecular distance is p…
Design of a narrow-band filter based on the Brewster phenomenon for microwave applications
2017
A high-efficiency narrow-band filter based on a Dielectric Frequency-Selective Surface (DFSS) has been predicted theoretically for oblique plane-wave incidence. A DFSS showing total reflection at a frequency of 10.5 GHz, based on the Brewster phenomenon for TM polarization, has been designed with a single dielectric grating, showing extremely low-reflectance sidebands adjacent to the resonance peak. The angular and spectral response of the designed filter has been studied. In addition, dielectric ohmic losses have been accounted for in this structure. This work was supported by the Agencia Estatal de Investigación (AEI) and by the Unión Europea through the Fondo Europeo de Desarrollo Region…
Manipulating spontaneous emission of the CsPbI3 Perovskite NCs using hybrid (HMM-Mie resonator) structures
2021
Keratoconus apex positions impact on visual acuity and contrast sensitivity
2020
The change of corneal shape in keratoconus subjects can impact the optical quality of the eye on the retina and it reduces the contrast sensitivity by light scattering. The aim of our study was to estimate the keratoconus subjects’ contrast sensitivity and visual acuity depending on keratoconus apex position. We included 45 keratoconus subjects (77 eyes), which have keratoconus in the first to the third stage, in our study. There were 33 eyes with keratoconus apex in the central part of the cornea and 46 eyes with keratoconus apex in the periphery of the cornea. Contrast sensitivity and visual acuity were measured at 3 m with and without the best possible spectacle correction using the FrAC…
Separate processing of “color” and “brightness” in goldfish
1991
Spectral sensitivity was measured under different adaptation levels using a behavioral training technique in which the fish had to discriminate between a dark test field and a test field illuminated with monochromatic light. Depending on which of the two test fields was used as training test field, two functions were obtained which differ (1) in absolute sensitivity and (2) in shape. When trained on the dark test field, the fish seems to discriminate on the basis of a "color" cue, but it uses a "brightness" cue when trained on the illuminated test field. This was concluded from measurements of wavelength discrimination. Under low levels of the adaptation light (1.5 and 0.2 lx instead of 20 …
A Design Methodology for Low-Power MCML Ring Oscillators
2007
In this paper, a low-power design method for MCML based ring oscillators is presented. The proposed method takes into account the parasitic capacitances of the MOS transistors. To validate it, some ring oscillators with different oscillation frequencies were designed in a 0.18 mum CMOS technology. SPICE simulations demonstrate the effectiveness of the design method.
Comparative Cytocompatibility and Mineralization Potential of Bio-C Sealer and TotalFill BC Sealer
2019
The aim of this study was to investigate the cytocompatibility and mineralization potential of two premixed hydraulic endodontic sealers compared with an epoxy resin-based root canal sealer. The cellular responses and mineralization capacity were studied in human periodontal ligament stem cells (hPDLSCs) that were exposed to premixed hydraulic sealers, Bio-C Sealer (Angelus, Londrí
The Evaluation of Four Electronic Apex Locators in Teeth with Simulated Horizontal Oblique Root Fractures
2008
The accuracy of four electronic apex locators (EALs) to locate the apical limit in teeth with simulated horizontal oblique root fractures was investigated. A horizontal oblique incomplete root fracture was simulated on 20 freshly extracted maxillary anterior teeth by means of a notch made on the vestibular root plane 8 mm from the anatomic apex. The EALs investigated were the ProPex (Dentsply Maillefer, Ballaigues, Switzerland), the NovApex (Forum Technologies, Rishon Le-Zion, Israel), the Root ZX (J. Morita Corp, Kyoto, Japan), and the Elements Apex Locator (SybronEndo, Orange CA). The electronic measurements were compared with the real "working length." The accuracy obtained was of 80% (n…