Search results for "ESR"
showing 10 items of 190 documents
Phenol compounds for Electron Spin Resonance (ESR) dosimetry in gamma and neutron field
2015
The use of neutrons for cancer treatments has stimulated the research for beam characterization in order to optimize the therapy procedures in Neutron Capture Therapy (Altieri, 2008). Several research laboratories have shown an increasing interest aimed at extending the applicability of Electron Spin Resonance (ESR) dosimetry to radiotherapy with different types of radiation beams. In particular, ESR spectrometry provides absorbed dose measurements through the detection of the stable free radicals produced by ionizing radiations. The ESR dosimetric method has many advantages such as simple and rapid dose evaluation, the readout procedure is non-destructive, linear response of many organic a…
ESR response of alanine films exposed to low-energy (1-40 keV) X-rays
2018
Introduction L-a-alanine has aroused considerable interest for use in radiation ESR dosimetry. In this work, we examined the energy response of alanine ESR films in the low energy X-photon energy range between 1 keV and 40 keV. Dose measurements through a reference ionization chamber and a semiconductor detection system were also performed to complement ESR measurements. Methods Commercial alanine ESR films were used. All ESR signal measurements were also done using an XBand (9.7 GHz) Bruker spectrometer. The dosimeters were irradiated at the "Livio Scarsi" Laboratory (LAX) of the University of Palermo, where X-ray beams in the 1–40 keV energy range are produced using a Seifert SN60 tube. R…
Riconoscimento e analisi del segnale della chitina nello spettro ESR di Mn2+ del guscio di scampi irradiati
2009
Studio della risposta di vetro minerale per dosimetria in emergenza radiologica
2009
The role of Electron Spin Resonance (ESR) spectroscopy in dosimetric and dating applications
2010
The use of gadolinium for ESR dosimetry
2010
The application of gadolinium to sensitize Electron Spin Resonance (ESR) dosimeters is reviewed. This nucleus is chosen because it has very good features in interacting with ionizing radiations. In particular, it has a very high capture cross section for thermal neutrons which favors the interactions of these particles within the detector; moreover, the charged secondary particles released after neutron interactions (mainly Auger and internal conversion electrons) are able to release their energy close the gadolinium site and, therefore, inside the sensitive volume of the detector. Consequently, the addition of gadolinium inside ESR dosimeters produces a significant enhancement of thermal n…
Indagini ESR su legni moderni e antichi.
2007
ESR spectroscopy for analyzing the spatial distribution of free radicals in ammonium tartrate
2013
ESR RESPONSE TO 60 CO-RAYS OF AMMONIUM TARTRATE PELLETS USING GD2O3 AS ADDITIVE.
2007
This work presents experimental results regarding a new ammonium tartrate blend for ESR dosimetry, with a higher sensitivity and a lower lowest detectable dose (LDD) to 60 Co -rays than the recently used pure ammonium tartrate. The blend composed by ammonium tartrate and gadolinium-oxide (Gd2 O3 ) shows a greater sensitivity (∼2 times) and a smaller LDD than ammonium tartrate. The increased sensitivity was mainly attributed to the great atomic number (Z = 64) of gadolinium, that increases the effective atomic number of the blend; the interaction probability with photons and consequently the radical yield is therefore enhanced. Moreover ammonium tartrate with Gd2 O3 has a linear dose respons…
The impact of humic substances on the liposome structures: ESR method
2013
In this paper the changes of membrane fluidity of liposome with additions of humic substances (humic and fulvic acids) were examined. Liposome were done by the sonication of lecithin EYL. Concentrations of humic substances in ttitude to EYL varied between 0–10% of weight. The technique of electron spin resonance (ESR) were used for the examination followed by three spin probes with a variety placement of the membrane located. TEMPO probe melted in the hydrophobic membrane and in the aquatic solution which allowed to determine the spectroscopic partition parameter (F), indicating the changes that occur in water-lipid interphase. Probe 5-DOXYL placed directly under the heads of polar lipids a…