Search results for "Elasticity"

showing 10 items of 736 documents

Compliance and Pulse Wave Velocity Assessed by MRI Detect Early Aortic Impairment in Young Patients With Mutation of the Smooth Muscle Myosin Heavy C…

2008

Purpose To evaluate aortic elasticity with MRI on young asymptomatic individuals with mutation of the smooth muscle myosin heavy chain in whom aortic enlargement is not present. Materials and Methods Aortic compliance, aortic distensibility, and pulse wave velocity (PWV) were semiautomatically measured from MRI in 8 asymptomatic subjects having a mutation of the MYH11 gene (M+) and 21 nonmutated relatives (M−) of similar age, sex, and blood pressure characteristics. Results Despite a similar aortic diameter in both groups, the aortic compliance and distensibility were significantly lower in M+ subjects compared with M− (0.84 ± 0.33 versus 2.03 ± 0.54 mm2/mmHg, 1.18 ± 0.62 10−3 versus 5.11 ±…

MalePulsatile flow030204 cardiovascular system & hematology030218 nuclear medicine & medical imaging0302 clinical medicinemagnetic resonance imaginggeneticsPulse wave velocityComputingMilieux_MISCELLANEOUSmedicine.diagnostic_test[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingPrognosisPulsatile FlowAortic valve stenosiscardiovascular systemCardiologyElasticity Imaging TechniquesFemalemedicine.symptomAlgorithmsBlood Flow VelocityAdultmedicine.medical_specialtypulse wave velocityAortic Valve InsufficiencySensitivity and SpecificityAsymptomaticYoung Adult03 medical and health sciencesElastic Modulusmedicine.arteryInternal medicineImage Interpretation Computer-Assistedmedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansGenetic Predisposition to DiseaseRadiology Nuclear Medicine and imagingAortaMyosin Heavy ChainsReceiver operating characteristicbusiness.industryReproducibility of ResultsMagnetic resonance imagingAortic Valve StenosisImage Enhancementmedicine.diseaseaortaBlood pressureMutationelasticitybusiness
researchProduct

Increased liver stiffness is associated with mortality in HIV/HCV coinfected subjects: The French nationwide ANRS CO13 HEPAVIH cohort study

2019

Background The association between liver stiffness measurements (LSM) and mortality has not been fully described. In particular the effect of LSM on all-cause mortality taking sustained virological response (SVR) into account needs further study. Methods HIV/HCV participants in the French nation-wide, prospective, multicenter ANRS CO13 HEPAVIH cohort, with ≥1 LSM by FibroScan (FS) and a detectable HCV RNA when the first valid FS was performed were included. Cox proportional hazards models with delayed entry were performed to determine factors associated with all-cause mortality. LSM and SVR were considered as time dependent covariates. Results 1,062 patients were included from 2005 to 2015 …

MaleRNA virusesSustained Virologic ResponseMetabolic disordersSocial SciencesHIV InfectionsHepacivirusmedicine.disease_causeGastroenterology0302 clinical medicineImmunodeficiency VirusesRisk FactorsPsychologyAlcohol consumptionProspective Studies030212 general & internal medicineProspective cohort studyPathology and laboratory medicineMultidisciplinaryDeath ratesCoinfectionHepatitis C virusMortality rateQHazard ratioRvirus diseasesHepatitis CMiddle AgedMedical microbiologyAddicts3. Good healthLiverDrug usersVirusesCohortElasticity Imaging TechniquesMedicineFemale030211 gastroenterology & hepatologyFrancePathogensResearch ArticleCohort studyAdultmedicine.medical_specialtyScienceHepatitis C virusLiver fibrosisAddictionGastroenterology and HepatologyAntiviral AgentsMicrobiology03 medical and health sciencesPopulation MetricsInternal medicineRetrovirusesmedicineHumansMortalityLiver diseasesProportional Hazards ModelsNutritionMedicine and health sciencesBiology and life sciencesFlavivirusesPopulation Biologybusiness.industryProportional hazards modelLentivirusOrganismsViral pathogensHIVHepatitis C Chronicmedicine.diseaseHepatitis virusesMicrobial pathogensDiet[SDV.SPEE] Life Sciences [q-bio]/Santé publique et épidémiologie[SDV.SPEE]Life Sciences [q-bio]/Santé publique et épidémiologiebusinessPLOS ONE
researchProduct

Aortic Function's Adaptation in Response to Exercise-Induced Stress Assessing by 1.5T MRI : A Pilot Study in Healthy Volunteers

2015

AIM:Evaluation of the aortic "elastic reserve" might be a relevant marker to assess the risk of aortic event. Our aim was to compare regional aortic elasticity at rest and during supine bicycle exercise at 1.5 T MRI in healthy individuals. METHODS:Fifteen volunteers (8 men), with a mean age of 29 (23-41) years, completed the entire protocol. Images were acquired immediately following maximal exercise. Retrospective cine sequences were acquired to assess compliance, distensibility, maximum rates of systolic distension and diastolic recoil at four different locations: ascending aorta, proximal descending aorta, distal descending aorta and aorta above the coeliac trunk level. Segmental aortic …

Male[INFO.INFO-IM] Computer Science [cs]/Medical Imaginglcsh:MedicineAorta ThoracicPilot Projects030204 cardiovascular system & hematologyCardiovascular MedicineVascular Medicine030218 nuclear medicine & medical imagingDiagnostic Radiology0302 clinical medicineDiastole[SPI.MECA.BIOM] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Biomechanics [physics.med-ph]Supine PositionMedicine and Health SciencesThoracic aortaPublic and Occupational Healthlcsh:SciencePulse wave velocityAortaMultidisciplinary[ INFO.INFO-IM ] Computer Science [cs]/Medical ImagingRadiology and Imaging[SPI.MECA.BIOM]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Biomechanics [physics.med-ph]Adaptation PhysiologicalHealthy VolunteersSports Science[SDV.MHEP.CSC] Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular systemPulmonary imagingCardiovascular diseasesDescending aortaVentricular pressureCardiologycardiovascular systemBlood pressureFemaleAnatomyResearch ArticleAdultmedicine.medical_specialtySystoleImaging TechniquesHeart rateCardiologyPulse Wave AnalysisResearch and Analysis Methods03 medical and health sciencesVascular StiffnessMagnetic resonance imaging[SDV.MHEP.CSC]Life Sciences [q-bio]/Human health and pathology/Cardiology and cardiovascular systemStress PhysiologicalDiagnostic Medicinemedicine.arteryInternal medicineAscending aortamedicine[INFO.INFO-IM]Computer Science [cs]/Medical ImagingHumansSystoleExerciseAortabusiness.industrylcsh:RBiology and Life SciencesPhysical ActivityElasticityBlood pressurePhysical FitnessCardiovascular AnatomyBlood Vesselslcsh:QSports and exercise medicinebusiness
researchProduct

Anterior Segment Biometry and Their Correlation with Corneal Biomechanics in Caucasian Children.

2018

Purpose: To assess the relationship between the corneal biomechanical parameters and the anterior segment parameters in Caucasian children. Methods: This study included 293 eyes from 293 healthy children aged between 6 and 17 years. Corneal hysteresis (CH) and corneal resistance factor (CRF) were evaluated with the Ocular Response Analyzer, axial length (AL) with IOLMaster and the anterior segment with Pentacam. Anterior segment parameters obtained were the following: central corneal thickness (CCT), corneal volume (CV), anterior chamber depth (ACD), anterior chamber volume (ACV) and mean anterior and posterior keratometry. Two multiple linear regression models were constructed to assess th…

Malemedicine.medical_specialtyBiometrygenetic structuresAdolescentanterior ocular segmentWhite Peoplelaw.inventionCorneal hysteresisCorrelationCorneaCorneal biomechanics03 medical and health sciencesCellular and Molecular Neuroscience0302 clinical medicinechildrenlawAnterior Eye SegmentReference ValuesStatistical significanceOphthalmologyLinear regressionMedicineHumansChildIntraocular PressureKeratometerbusiness.industryBiomechanicsCorneal TopographyAxial lengtheye diseasesSensory SystemsElasticityOphthalmologyCross-Sectional Studies030221 ophthalmology & optometryFemalesense organsocular response analyzerbusiness030217 neurology & neurosurgeryCurrent eye research
researchProduct

A Sequential Algorithm Combining ADAPT and Liver Stiffness Can Stage Metabolic-Associated Fatty Liver Disease in Hospital-Based and Primary Care Pati…

2020

INTRODUCTION Metabolic-associated fatty liver disease is common, with fibrosis the major determinant of adverse outcomes. Population-based screening tools with high diagnostic accuracy for the staging of fibrosis are lacking. METHODS Three independent cohorts, 2 with both liver biopsy and liver stiffness measurements (LSMs, n = 254 and 65) and a population sample (n = 713), were studied. The performance of a recently developed noninvasive algorithm (ADAPT [age, diabetes, PRO-C3 and platelets panel]) as well as aspartate aminotransferase-to-platelet ratio index, fibrosis-4, nonalcoholic fatty liver disease fibrosis score, and LSM was used to stage patients for significant (≥F2) and advanced …

Malemedicine.medical_specialtyBiopsyPopulationGastroenterology03 medical and health sciences0302 clinical medicineFibrosisNon-alcoholic Fatty Liver DiseasePredictive Value of TestsDiabetes mellitusInternal medicineNonalcoholic fatty liver diseasemedicineDiabetes MellitusHumansAspartate Aminotransferaseseducationeducation.field_of_studyHepatologymedicine.diagnostic_testReceiver operating characteristicbusiness.industryPlatelet CountFatty liverGastroenterologyAge FactorsOdds ratioMiddle Agedmedicine.diseaseCollagen Type III030220 oncology & carcinogenesisLiver biopsyElasticity Imaging Techniques030211 gastroenterology & hepatologyFemalebusinessAlgorithmsBiomarkersThe American journal of gastroenterology
researchProduct

Electromyographic comparison of elastic resistance and machine exercises for high-intensity strength training in patients with chronic stroke

2016

To investigate whether elastic resistance training can induce comparable levels of muscle activity as conventional machine training in patients with chronic stroke.Comparative study.Outpatient rehabilitation facility.Stroke patients (N=18) with hemiparesis (mean age, 57 ± 8y).Patients performed 3 consecutive repetitions at 10 repetition maximum of unilateral knee extension and flexion using elastic resistance and conventional machine training.Surface electromyography was measured in vastus lateralis, vastus medialis, biceps femoris, and semitendinosus and was normalized to maximal electromyography (% of max) of the nonparetic leg.In the paretic leg, agonist muscle activity ranged from 18% t…

Malemedicine.medical_specialtyVastus medialisStrength trainingPhysical Therapy Sports Therapy and RehabilitationElectromyographyBiceps03 medical and health sciences0302 clinical medicinePhysical medicine and rehabilitationmedicineHumansLegmedicine.diagnostic_testbusiness.industryElectromyographyRehabilitationStroke RehabilitationResistance Training030229 sport sciencesMiddle Agedmusculoskeletal systemCoactivationConfidence intervalElasticityParesisStrokeHemiparesisTreatment OutcomeAnesthesiaChronic DiseaseFemalemedicine.symptomRange of motionbusiness030217 neurology & neurosurgery
researchProduct

Is the cardholder an efficient alarm system to detect credit card incidents?

2015

There is a growing tendency in credit card industry to increase the contribution of the smallest players, the cardholders, in the detection of card incidents. This article examines whether cardholders are efficient at detecting/communicating incidents of theft, loss or fraudulent use of their cards. The analysis focuses on whether they demonstrate enough speed of response to support a risk control subsystem by the issuer. The research follows a completely new approach showing how the issue can be handled by applying the concept of elasticity, a notion just recently exported from economics to the field of statistics by linking it with the reverse hazard rate. The issue is focused on the anal…

MarketingEconomics and EconometricsActuarial sciencebusiness.industryComputer science05 social sciencesPublic Health Environmental and Occupational HealthComputer securitycomputer.software_genre01 natural sciencesElasticity of a functionRisk perception010104 statistics & probabilityALARMCredit cardIssuer0502 economics and businessRisk Control050211 marketing0101 mathematicsbusinesscomputerApplied PsychologyRisk managementCredit card interestInternational Journal of Consumer Studies
researchProduct

Spatial mapping of price competition using logit-type market share models and store-level scanner-data

2009

This paper proposes a methodology to obtain reliable spatial maps of price competition using store-level scanner data. Specifically, a procedure to obtain a symmetric matrix of similarities between brands considering their substitutability depending on price variations is proposed. The matrix is derived from a market response model where price cross-effects are split into two components. The first component accounts for the fact that price variation in one brand can have different effects to price variation in other brands (ie j → j′≠j′ → j). The second component accounts for the fact that the price of each brand can have different effects across competing brands (ie j → j′≠j → j ″). The ma…

MarketingInventory controlCross elasticity of demandOperations researchStrategy and Management05 social sciencesLogitManagement Science and Operations Research050105 experimental psychologyPurchasingManagement Information SystemsMarket structure0502 economics and businessEconomicsMarket priceEconometricsSymmetric matrix050211 marketing0501 psychology and cognitive sciencesMarket shareComputer Science::DatabasesJournal of the Operational Research Society
researchProduct

Stationary and non-stationary stochastic response of linear fractional viscoelastic systems

2012

Abstract A method is presented to compute the stochastic response of single-degree-of-freedom (SDOF) structural systems with fractional derivative damping, subjected to stationary and non-stationary inputs. Based on a few manipulations involving an appropriate change of variable and a discretization of the fractional derivative operator, the equation of motion is reverted to a set of coupled linear equations involving additional degrees of freedom, the number of which depends on the discretization of the fractional derivative operator. As a result of the proposed variable transformation and discretization, the stochastic analysis becomes very straightforward and simple since, based on stand…

Markov chainDiscretizationStochastic processMechanical EngineeringMathematical analysisDegrees of freedom (statistics)Stochastic calculusAerospace EngineeringOcean EngineeringStatistical and Nonlinear PhysicsViscoelasticity Fractional calculus Stochastic input Non-stationary responseCondensed Matter PhysicsFractional calculusOperator (computer programming)Nuclear Energy and EngineeringSettore ICAR/08 - Scienza Delle CostruzioniLinear equationCivil and Structural EngineeringMathematics
researchProduct

Markovian approximation of linear systems with fractional viscoelastic term

2017

It is well known that the response of a linear system enforced by a Gaussian white noise is Markovian. The order of Markovianity is n-1 being n the maximum order of the derivative of the equation ruling the evolution of the system. However when a fractional operator appears, the order of Markovianity of the system becomes infinite. Then the main aim developed in the proposed paper, consists of rewriting the system with fractional term of order r with an "equivalent" one, in which the fractional operator is substituted by two classical differential terms with integer order of derivative int(r) and int(r + 1) (for a real r). In this way the fractional differential equation reverts into a clas…

Markovianity.Mechanics of MaterialsMechanical EngineeringFractional viscoelasticityLinear systemSettore ICAR/08 - Scienza Delle Costruzioni
researchProduct