Search results for "Electrical impedance"

showing 10 items of 183 documents

Evaluation of an Optical Energy Harvester for SHM Application

2019

Abstract In this paper a preliminary study on an array configuration of rectified optical nanoantennas for energy harvesting application is proposed. Currently, the major impediments for the use of the rectified optical nanoantenna known as rectenna are the relatively low conversion efficiency and low power transfer to the load, both of them caused mainly by the mismatch between the impedance of the rectifier (several kilo ohms) and that of the antenna (hundreds of ohm). For this reason, the design of the array represents a crucial point to obtain the maximum energy transfer from the rectenna to the load, represented as a typical DC/DC boost power converter, and modeled by an equivalent inp…

Computer sciencebusiness.industryImpedance matchingElectrical engineeringImpedance and voltage matching Optical rectennas array Rectenna Structural Health Monitoring (SHM)020206 networking & telecommunications02 engineering and technologySettore ING-INF/01 - Elettronica03 medical and health sciencesRectifierRectenna0302 clinical medicine0202 electrical engineering electronic engineering information engineeringMaximum power transfer theoremStructural health monitoringElectrical and Electronic EngineeringAntenna (radio)businessEnargy Harvesting Nanoantennas Structural Health MonitoringEnergy harvestingElectrical impedance030217 neurology & neurosurgery
researchProduct

EQCM and Quartz Crystal Impedance Measurements for the Characterization of Thiophene-Based Conducting Polymers

1999

AbstractEQCM was extensively used to investigate ion-transport phenomena during dopingundoping processes of electronically conducting polymers. Several early studies assumed that the polymer films were rigidly coupled to the quartz crystal so as to relate the mass change to the quartz crystal resonant frequency change via the Sauerbrey equation. However, the rigidity of electronically conducting polymer films is doubtful and it has to be demonstrated. Quartz crystal impedance analysis near the resonance is of paramount importance to get insight into the viscoelastic properties of the film [1] and to avoid misleading in the interpretation of EQCM data.This contribution presents and discusses…

Conductive polymerCrystalchemistry.chemical_classificationMaterials sciencechemistrySauerbrey equationResonancePolymerComposite materialQuartzElectrical impedanceViscoelasticityMRS Proceedings
researchProduct

Short-term walking physical training and changes in body hydration status, B-type natriuretic peptide and C-reactive protein levels in compensated co…

2008

BACKGROUND: Congestive heart failure (CHF) is associated with decreased exercise tolerance, alterations in body fluid balance and activation of neurohumoral and inflammatory pathways. Physical training, despite the contraindications of the past, is recommended for its beneficial effects on exercise capacity and quality of life. We investigate the effects of a short-term (ten weeks) walking physical training program (PT) on body hydration state (HS), B-type natriuretic peptide (BNP) and C-reactive protein (CRP) levels. METHODS AND RESULTS: 22 patients with CHF (mean age 62.7+/-4.8 years, 15 men, mean ejection fraction 38.9+/-3.6%, NYHA class II-III), were enrolled. Eleven patients were rando…

Congestive heart failureWalking physical training programMalemedicine.medical_specialtyHeart diseasemedicine.drug_classWalkingBody WaterInternal medicinemedicineNatriuretic peptideElectric ImpedanceHumansBody fluidHeart FailureEjection fractionExercise Tolerancebiologybusiness.industryC-reactive proteinAcute-phase proteinNatriuretic Peptide C-TypeMiddle Agedmedicine.diseaseExercise TherapyEndocrinologyC-Reactive ProteinB-type natriuretic peptideHeart failureBioelectrical impedance analysiCardiologybiology.proteinFemaleCardiology and Cardiovascular MedicinebusinessBioelectrical impedance analysisInternational journal of cardiology
researchProduct

A DC and small signal AC model for organic thin film transistors including contact effects and non quasi static regime

2017

Abstract We present a compact model for the DC and small signal AC analysis of Organic Thin Film Transistors (OTFTs). The DC part of the model assumes that the electrical current injected in the OTFT is limited by the presence of a metal/organic semiconductor junction that, at source, acts as a reverse biased Schottky junction. By including this junction, modeled as a reverse biased gated diode at source, the DC model is able to reproduce the scaling of the electrical characteristics even for short channel devices. The small signal AC part of the model uses a transmission line approach in order to compute the impedances of the channel and parasitic regions of the device. The overlap capacit…

DC modelMaterials scienceContact effectsparasitic capacitanceSchottky barrierOrganic thin film transistors02 engineering and technologyHybrid-pi model01 natural sciencesSignalNon-quasi static small signal modelBiomaterialsOrganic thin film transistors; DC model; AC model; Contact effects; parasitic capacitance; Non-quasi static small signal modelParasitic capacitanceTransmission line0103 physical sciencesHardware_INTEGRATEDCIRCUITSMaterials ChemistryAC modelElectrical and Electronic EngineeringElectrical impedance010302 applied physicsbusiness.industryGeneral Chemistry021001 nanoscience & nanotechnologyCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsOrganic semiconductorThin-film transistorOptoelectronics0210 nano-technologybusinessOrganic Electronics
researchProduct

Body composition in 18 to 88-year-old adults - comparison of multifrequency bioimpedance and dual-energy X-ray absorptiometry

2014

Objective -- This study compared bioimpedance analysis (BIA) in the assessment of body composition with dual-energy X-ray absorptiometry (DXA) in 18- to 88-year-old adults. Design and Methods -- Body composition of 882 adults was estimated by eight-polar BIA and DXA. In addition, estimates of lean mass, fat mass, and percentage of fat were investigated across a range of age and leisure time physical activity (LTPA) groups. Results -- Compared to DXA, larger lean masses (mean difference 2.9 and 1.6 kg) and smaller fat masses (3.1 and 2.6 kg) were estimated by BIA in both women and men, respectively. Differences between the methods' mean values were evident in all age and LTPA groups, except …

DXABIAdual-energy x-ray absorptiometry (DXA)rasvaprosenttibioimpedanssianalyysibioelectrical impedance method (BIA)rasvakudoksethuman activitiesmittausmenetelmätkehonkoostumus
researchProduct

The Importance of the Nurse’s Role in the Management of Complex Diabetic Outpatients: It is the Time to Manage Patient’s Multidimensions

2018

none

Diabetes Quality of lifemedicine.medical_specialtyUltrasound scanComorbiditylaw.invention03 medical and health sciences0302 clinical medicineClinical pathwaylawMedicineTherapeutic ReconciliationClinical ComplexityNursing AssessmentDepression (differential diagnoses)PolypharmacyClinical pharmacology030214 geriatricsbusiness.industryOutpatientDiabetes MellituGeneral MedicineSettore MED/45 - Scienze Infermieristiche Generali Cliniche E PediatrichePatient Care ManagementNutritionistChronic DiseasePhysical therapyGeriatric Depression ScalebusinessBioelectrical impedance analysisNeeds AssessmentBiomedical Journal of Scientific & Technical Research
researchProduct

Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT)

2013

BACKGROUND: Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. METHODOLOGY/PRINCIPAL FINDINGS: Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) …

Diagnostic ImagingPathologymedicine.medical_specialtyAnatomy and PhysiologyCritical Care and Emergency MedicinePulmonologyVibration Response ImagingSwineRespiratory SystemLung soundlcsh:MedicineVibrationModel OrganismsRespiratory FailureAnesthesiologyBedside TechnologyElectric ImpedancemedicineMedical imagingAnimalsRespiratory Physiologyddc:610lcsh:ScienceTomographyBiologyElectrical impedance tomographyAnesthesiology MonitoringPhysicsAnalysis of VarianceModels StatisticalAnesthesiology TechnologyMultidisciplinarylcsh:RAnimal Modelsrespiratory systemrespiratory tract diseasesPulmonary imagingSpirometryBreathingMedicinelcsh:QTomographyPulmonary VentilationResearch ArticleBiomedical engineering
researchProduct

Novel technologies to detect atelectotrauma in the injured lung

2010

ABSTRACTCyclical recruitment and derecruitment of lung parenchyma (R/D) remains a serious problem in ALI/ARDS patients, defined as atelectotrauma. Detection of cyclical R/D to titrate the optimal respiratory settings is of high clinical importance. Image-based technologies that are capable of detecting changes of lung ventilation within a respiratory cycle include dynamic computed tomography (dCT), synchrotron radiation computed tomography (SRCT), and electrical impedance tomography (EIT). Time-dependent intra-arterial oxygen tension monitoring represents an alternative approach to detect cyclical R/D, as cyclical R/D can result in oscillations of PaO2 within a respiratory cycle. Continuous…

Diagnostic ImagingPulmonary and Respiratory MedicinePathologymedicine.medical_specialtyARDSAcute Lung InjuryClinical BiochemistrySeverity of Illness IndexPredictive Value of TestsImage Interpretation Computer-AssistedElectric ImpedancemedicineHumansOximetryRespiratory systemMolecular BiologyElectrical impedance tomographyRespiratory Distress SyndromeLungmedicine.diagnostic_testbusiness.industryOxygenationrespiratory systemPrognosismedicine.diseaseRespiration Artificialrespiratory tract diseasesOxygen tensionPulse oximetrymedicine.anatomical_structureTomographyTomography X-Ray ComputedbusinessBiomedical engineering
researchProduct

Electrical Characterization of the Fe-Doped BT Ceramics by an Impedance Spectroscopy

2015

The electric properties of the Fe - doped BaTiO3 ceramics was investigated as a function of frequency and temperature. The structure and morphology of investigated sample were characterized by an X-ray diffraction and scanning electron microscopy. The impedance measurements were carried out at the temperature ranging from 450 K to 600 K, and at the frequency range from 0.1 Hz to 10 MHz. Based on these parameters the electrical properties of the grains and grains boundaries were described. The bulk and grains boundaries resistance of ceramics and the thermal activation energies were determined.

DiffractionMaterials scienceMorphology (linguistics)Scanning electron microscopeCondensed Matter PhysicsElectronic Optical and Magnetic MaterialsDielectric spectroscopyCharacterization (materials science)visual_artThermalvisual_art.visual_art_mediumCeramicComposite materialElectrical impedanceFerroelectrics
researchProduct

Decoupled solution of radial and weakly meshed distribution networks through a backward method

2008

A methodology for the analysis of radial or weakly meshed distribution systems supplying voltage dependent loads is developed. The solution process is iterative and, at each step, the loads are simulated by means of impedances. The network is divided into two sub-networks which must be solved separately and sequentially; in the first, named RP-net, only the lines resistances and the loads shunt equivalent resistances are considered; in the second, named XQ-net, only the lines reactances and the shunt equivalent reactances are taken into account. After a brief presentation of the b/f method, which is currently the most commonly used technique to solve distribution networks, the proposed meth…

Distribution systemEngineeringDistribution networksbusiness.industryLoad modelingElectronic engineeringBackward/forward method distribution networks power flows.AC powerbusinessTopologyTransfer functionElectrical impedanceVoltage2008 IEEE/PES Transmission and Distribution Conference and Exposition: Latin America
researchProduct