Search results for "Electrical impedance"
showing 10 items of 183 documents
Evaluation of an Optical Energy Harvester for SHM Application
2019
Abstract In this paper a preliminary study on an array configuration of rectified optical nanoantennas for energy harvesting application is proposed. Currently, the major impediments for the use of the rectified optical nanoantenna known as rectenna are the relatively low conversion efficiency and low power transfer to the load, both of them caused mainly by the mismatch between the impedance of the rectifier (several kilo ohms) and that of the antenna (hundreds of ohm). For this reason, the design of the array represents a crucial point to obtain the maximum energy transfer from the rectenna to the load, represented as a typical DC/DC boost power converter, and modeled by an equivalent inp…
EQCM and Quartz Crystal Impedance Measurements for the Characterization of Thiophene-Based Conducting Polymers
1999
AbstractEQCM was extensively used to investigate ion-transport phenomena during dopingundoping processes of electronically conducting polymers. Several early studies assumed that the polymer films were rigidly coupled to the quartz crystal so as to relate the mass change to the quartz crystal resonant frequency change via the Sauerbrey equation. However, the rigidity of electronically conducting polymer films is doubtful and it has to be demonstrated. Quartz crystal impedance analysis near the resonance is of paramount importance to get insight into the viscoelastic properties of the film [1] and to avoid misleading in the interpretation of EQCM data.This contribution presents and discusses…
Short-term walking physical training and changes in body hydration status, B-type natriuretic peptide and C-reactive protein levels in compensated co…
2008
BACKGROUND: Congestive heart failure (CHF) is associated with decreased exercise tolerance, alterations in body fluid balance and activation of neurohumoral and inflammatory pathways. Physical training, despite the contraindications of the past, is recommended for its beneficial effects on exercise capacity and quality of life. We investigate the effects of a short-term (ten weeks) walking physical training program (PT) on body hydration state (HS), B-type natriuretic peptide (BNP) and C-reactive protein (CRP) levels. METHODS AND RESULTS: 22 patients with CHF (mean age 62.7+/-4.8 years, 15 men, mean ejection fraction 38.9+/-3.6%, NYHA class II-III), were enrolled. Eleven patients were rando…
A DC and small signal AC model for organic thin film transistors including contact effects and non quasi static regime
2017
Abstract We present a compact model for the DC and small signal AC analysis of Organic Thin Film Transistors (OTFTs). The DC part of the model assumes that the electrical current injected in the OTFT is limited by the presence of a metal/organic semiconductor junction that, at source, acts as a reverse biased Schottky junction. By including this junction, modeled as a reverse biased gated diode at source, the DC model is able to reproduce the scaling of the electrical characteristics even for short channel devices. The small signal AC part of the model uses a transmission line approach in order to compute the impedances of the channel and parasitic regions of the device. The overlap capacit…
Body composition in 18 to 88-year-old adults - comparison of multifrequency bioimpedance and dual-energy X-ray absorptiometry
2014
Objective -- This study compared bioimpedance analysis (BIA) in the assessment of body composition with dual-energy X-ray absorptiometry (DXA) in 18- to 88-year-old adults. Design and Methods -- Body composition of 882 adults was estimated by eight-polar BIA and DXA. In addition, estimates of lean mass, fat mass, and percentage of fat were investigated across a range of age and leisure time physical activity (LTPA) groups. Results -- Compared to DXA, larger lean masses (mean difference 2.9 and 1.6 kg) and smaller fat masses (3.1 and 2.6 kg) were estimated by BIA in both women and men, respectively. Differences between the methods' mean values were evident in all age and LTPA groups, except …
The Importance of the Nurse’s Role in the Management of Complex Diabetic Outpatients: It is the Time to Manage Patient’s Multidimensions
2018
none
Assessment of regional ventilation distribution: comparison of vibration response imaging (VRI) with electrical impedance tomography (EIT)
2013
BACKGROUND: Vibration response imaging (VRI) is a bedside technology to monitor ventilation by detecting lung sound vibrations. It is currently unknown whether VRI is able to accurately monitor the local distribution of ventilation within the lungs. We therefore compared VRI to electrical impedance tomography (EIT), an established technique used for the assessment of regional ventilation. METHODOLOGY/PRINCIPAL FINDINGS: Simultaneous EIT and VRI measurements were performed in the healthy and injured lungs (ALI; induced by saline lavage) at different PEEP levels (0, 5, 10, 15 mbar) in nine piglets. Vibration energy amplitude (VEA) by VRI, and amplitudes of relative impedance changes (rel.ΔZ) …
Novel technologies to detect atelectotrauma in the injured lung
2010
ABSTRACTCyclical recruitment and derecruitment of lung parenchyma (R/D) remains a serious problem in ALI/ARDS patients, defined as atelectotrauma. Detection of cyclical R/D to titrate the optimal respiratory settings is of high clinical importance. Image-based technologies that are capable of detecting changes of lung ventilation within a respiratory cycle include dynamic computed tomography (dCT), synchrotron radiation computed tomography (SRCT), and electrical impedance tomography (EIT). Time-dependent intra-arterial oxygen tension monitoring represents an alternative approach to detect cyclical R/D, as cyclical R/D can result in oscillations of PaO2 within a respiratory cycle. Continuous…
Electrical Characterization of the Fe-Doped BT Ceramics by an Impedance Spectroscopy
2015
The electric properties of the Fe - doped BaTiO3 ceramics was investigated as a function of frequency and temperature. The structure and morphology of investigated sample were characterized by an X-ray diffraction and scanning electron microscopy. The impedance measurements were carried out at the temperature ranging from 450 K to 600 K, and at the frequency range from 0.1 Hz to 10 MHz. Based on these parameters the electrical properties of the grains and grains boundaries were described. The bulk and grains boundaries resistance of ceramics and the thermal activation energies were determined.
Decoupled solution of radial and weakly meshed distribution networks through a backward method
2008
A methodology for the analysis of radial or weakly meshed distribution systems supplying voltage dependent loads is developed. The solution process is iterative and, at each step, the loads are simulated by means of impedances. The network is divided into two sub-networks which must be solved separately and sequentially; in the first, named RP-net, only the lines resistances and the loads shunt equivalent resistances are considered; in the second, named XQ-net, only the lines reactances and the shunt equivalent reactances are taken into account. After a brief presentation of the b/f method, which is currently the most commonly used technique to solve distribution networks, the proposed meth…