Search results for "Electrochromatography"

showing 10 items of 50 documents

Application of molecularly imprinted polymers in analytical chiral separations and analysis

2018

Over the last two decades the process of development and application of a new types of molecular imprinted polymer (MIP) sorbents in the field of analytical chemistry have been widely described in the literature. One of the new trends in analytical chemistry practice is the use of new types of MIP sorbents as specific sorption materials constituting the stationary phase in advanced separation techniques. The following review paper contains comprehensive information about the application of a specific and well defined MIP sorbents (with the data base in the paper about the reagents used in MIP preparation process) as stationary phases in separation techniques including high performance liqui…

Capillary electrochromatographychiral separationMaterials sciencehigh performance liquid chromatography010401 analytical chemistryMolecularly imprinted polymerEnantioselective synthesisNanotechnologySorptionenantiomers02 engineering and technologycapillary electrochromatography021001 nanoscience & nanotechnology01 natural sciences0104 chemical sciencesAnalytical ChemistryStationary phasemolecularly imprinted polymers0210 nano-technologySpectroscopyTrac-Trends in Analytical Chemistry
researchProduct

Classification of extra virgin olive oils according to their geographical origin using phenolic compound profiles obtained by capillary electrochroma…

2009

Abstract A simple and reliable method for the evaluation of the phenolic fraction of extra virgin olive oils (EVOO) by capillary electrochromatography (CEC) with UV–Vis detection, using lauryl acrylate (LA) ester-based monolithic columns, has been developed. The percentages of the porogenic solvents in the polymerization mixture, and the mobile phase composition, were optimized. The optimum monolith was obtained with a monomers/porogens ratio of 40:60% (wt/wt) using a LA/1,3-butanediol diacrylate ratio of 70:30% (wt/wt) and a 1,4-butanediol/1-propanol ratio of 25:75% (wt/wt). A satisfactory resolution between the phenolic compounds was achieved in less than 25 min with a 15:85 (v/v) ACN–wat…

Capillary electrochromatographygeographyAcrylategeography.geographical_feature_categoryChromatographyGEOGRAPHICAL ORIGINResolution (mass spectrometry)Formic acidFraction (chemistry)chemistry.chemical_compoundVegetable oilLAURYL ACRYLATE-BASED MONOLITHIC COLUMNSLINEAR DISCRIMINANT ANALYSISchemistryEXTRA VIRGIN OLIVE OILSPhenolsMonolithCECFood ScienceFood Research International
researchProduct

Novel general expressions that describe the behavior of the height equivalent of a theoretical plate in chromatographic systems involving electricall…

2002

Novel general expressions are constructed and presented that describe the behavior of the height equivalent of a theoretical plate (plate height), H, as a function of the linear velocity, Vx, along the axis, x, of the column and the kinetic parameters that characterize the mass transfer and adsorption mechanisms in chromatographic columns. Open tube capillaries as well as columns packed with either non-porous or porous particles are studied. The porous particles could have unimodal or bimodal pore-size distributions and intraparticle convective fluid flow and pore diffusion are considered. The expressions for the plate height, H, presented in this work could be applicable to high-performanc…

ChromatographyChemistryOrganic ChemistryAnalytical chemistryElectro-osmosisGeneral MedicineModels TheoreticalKinetic energyBiochemistryAnalytical ChemistryElectrochromatographyMass transferFluid dynamicsTheoretical plateDiffusion (business)PorosityChromatography High Pressure LiquidJournal of Chromatography A
researchProduct

Separation of selected peptides by capillary electroendoosmotic chromatography using 3 μm reversed-phase bonded silica and mixed-mode phases

1999

The retention behaviour and selectivity of selected basic, neutral and acidic peptides have been studied by capillary electroendoosmotic chromatography (CEC) with Hypersil C8, C18, Hypersil mixed-mode, and Spherisorb C18/SCX columns, 250 (335) mm x 100 microns, packed with 3 microns particles, and eluted with mobile phases composed of acetonitrile-triethylamine-phosphoric acid (TEAP) at pH 3.0 using a Hewlett-Packard Model HP3DCE capillary electrophoresis system. The selected peptides were desmopressin (D), two analogues (A and B) of desmopressin, oxytocin (O) and carbetocin (C). The peptides eluted either before or after the electroendoosmotic flow (EOF) marker, depending on the concentrat…

ChromatographyChromatographyChemistryElutionOrganic ChemistryAnalytical chemistryGeneral MedicineReversed-phase chromatographyOxytocinSilicon DioxideBiochemistryHigh-performance liquid chromatographyAnalytical ChemistryElectrophoresisCapillary electrophoresisElectrochromatographyIonic strengthDeamino Arginine VasopressinPeptidesChromatography High Pressure LiquidStokes radiusJournal of Chromatography A
researchProduct

Comparative study of capillary electroendosmotic chromatography and electrically assisted gradient nano-liquid chromatography for the separation of p…

2000

Capillary electroendoendosmotic chromatography (CEC), being a hybrid of high-performance liquid chromatography (HPLC) and capillary electrophoresis, offers considerable changes to enhance column efficiency, speed of analysis and additional selectivity as compared to the parent methods. The analytes are driven by the electroendosmotic flow (EOF) and separated by surface-solute interactions as well as by differences in electromigration. In this paper on the separation of peptides on C18 reversed-phase and mixed-mode (sulphonic acid-n-alkyl) packings in CEC and electrically assisted reversed-phase gradient nano-LC are investigated. It is shown that mixed mode packings generate a higher EOF tha…

ChromatographyElutionChemistryOrganic ChemistryAnalytical chemistryElectrophoresis CapillaryCytochrome c GroupGeneral MedicineReversed-phase chromatographyHydrogen-Ion ConcentrationBiochemistryHigh-performance liquid chromatographyAngiotensin IIAnalytical ChemistryCapillary electrophoresisColumn chromatographyMixed-mode chromatographyElectrochromatographyPeptidesChromatography High Pressure LiquidJournal of chromatography. A
researchProduct

A direct Capillary Liquid Chromatography with electrochemical detection method for determination of phenols in water samples

2010

A fast and direct method based on the use of Capillary Liquid Chromatography (LC) with electrochemical (EC) detection has been described for phenols pollutants in water samples. Concretely, phenol, o-cresol, 2-chlorophenol and bisphenol A have been selected as target analytes. The combination of Capillary LC with EC detection avoided the necessity of preconcentration steps typically used in environmental analysis. The sample injected volume was 2 μL. The achieved detection limits were between 1 and 2 μg/L and the linear dynamic range was up to 50 μg/L for all studied phenols. The precision and uncertainty were satisfactory. The analysis time per sample was 10 min. The proposed procedure has…

Detection limitAnalyteChromatographyEnvironmental analysisCapillary actionOrganic ChemistryAnalytical chemistryReproducibility of ResultsFresh WaterGeneral MedicineSensitivity and SpecificityBiochemistryHigh-performance liquid chromatographyAnalytical Chemistrychemistry.chemical_compoundPhenolschemistryCapillary ElectrochromatographyLinear ModelsPhenolSeawaterPhenolsQuantitative analysis (chemistry)Water Pollutants ChemicalJournal of Chromatography A
researchProduct

Evaluation of 2,3-epoxypropyl groups and functionalization yield in glycidyl methacrylate monoliths using gas chromatography

2014

Abstract Poly(glycidyl methacrylate- co -ethylene dimethacrylate) (poly(GMA- co -EDMA)) is most frequently used as parent monolith to obtain stationary phases with a variety of surface chemistries for liquid chromatography and capillary electrochromatography. Functionalization is performed by opening the accessible 2,3-epoxypropyl groups of the monolith with a suitable reagent. The number of 2,3-epoxypropyl groups which are accessible before and after the functionalization reaction, and the grafting yield, are important parameters, required both to optimize functionalization and to interpret the chromatographic performance of functionalized monoliths. In this work, a method capable of provi…

DiethylaminegeographyCapillary electrochromatographyGlycidyl methacrylateChromatography Gasgeography.geographical_feature_categoryChromatographyOrganic ChemistryGeneral MedicineSilicon DioxideLithium aluminium hydrideMethacrylateBiochemistryChemistry Techniques AnalyticalAnalytical Chemistrychemistry.chemical_compoundchemistryCapillary ElectrochromatographyReagentEpoxy CompoundsMethacrylatesMethylmethacrylatesSurface modificationMonolithJournal of Chromatography A
researchProduct

Selectivity tuning in pressurized-flow electrochromatography

1996

Abstract Pressurized-flow electrochromatography (PEC) is a developing separation technique in which both a pressure gradient and an electric field are applied across a packed capillary. In this work we present new results illustrating the principles and the potential of PEC. Home-made capillary columns with silica-based reversed phase packings were operated under PEC conditions separating low molecular weight analytes. Compared to the purely pressure-driven system enhanced selectivity for the charged analytes was observed. It is shown that the retention time of a retained cationic analyte in PEC can be calculated using the chromatographic capacity factor and the electrophoretic mobility of …

ElectrophoresisCapillary electrochromatographyAnalyteChromatographyElectrochromatographyChemistryCapillary actionAnalytical chemistryElectro-osmosisSelectivitySpectroscopyCapacity factorAnalytical ChemistryTrAC Trends in Analytical Chemistry
researchProduct

Evanescent wave-initiated photopolymerisation as a new way to create monolithic open-tubular capillary columns: use as enzymatic microreactor for on-…

2010

Evanescent wave-initiated photopolymerisation in an optically wave guiding PTFE-coated fused silica capillary using light-emitting diode as a light source, is established here as a way to fabricate monolithic porous layer open-tubular capillary columns with a potential in capillary separation methods; application of the obtained open-tubular columns as enzymatic microreactors for on-line protein digestion is demonstrated.

Evanescent waveUltraviolet RaysProtein digestionCapillary actionBiochemistryMass SpectrometryAnalytical ChemistryBioreactorsLight sourceCapillary ElectrochromatographyElectrochemistryAnimalsEnvironmental ChemistryHorsesPorous layerPolytetrafluoroethyleneSpectroscopyChromatographyMyoglobinChemistryProteinsSilicon DioxidePepsin ALine (electrical engineering)EnzymesChemical engineeringSeparation methodMicroreactorPorosityThe Analyst
researchProduct

Multiple voltage‐gradient gel electrophoresis system

2001

A new device, based on the principle of voltage-gradient gel electrophoresis, was developed in order to enhance differentiation of the distance across the range of molecular masses in the electrophoretic fractionation of nucleic acids in an agarose matrix. The apparatus has a series of modular parallel plates, placed slantwise to allow reiteration of the voltage gradient effect along the gel. This subjects DNA fragments of variable length to differential runnings according to their original position in the gel. Both the number of slantwise plates and the distance between them can be changed to modify operating performance. Our system allows better fractionations as compared to conventional …

Gel electrophoresisTwo-dimensional gel electrophoresisGel electrophoresis of nucleic acidsDifference gel electrophoresisClinical BiochemistryAnalytical chemistryBiochemistryAnalytical Chemistrychemistry.chemical_compoundchemistryElectrochromatographyMolecular-weight size markerPulsed-field gel electrophoresisAgaroseELECTROPHORESIS
researchProduct